Version 8.2 (2013-03-18)
 —  Layout Elements  —

Some Common Rules for all Controls

This document covers the following topics:


Name and Text ID

Every time a control needs a static text definition (the name of a button or the name of a label), there are always two possibilities to define this text:

Top of page

Table, Row, Column, Control

Most controls that allow dynamic sizing offer the following properties:

These properties influence the way how controls are placed into container rows.

For users of previous releases: the width property is deprecated. The rendering can be controlled by COLSPAN and ROWSPAN now. In addition, there is the CELLSPAN control allowing you to group your controls.

Top of page

Explicit Alignment

Controls are put into table columns. If the column is wider or higher than the control itself, then you can explicitly control the vertical and horizontal alignment of the control inside the columns.

Most controls offer two properties:

Pay attention: valign and align only affect the position of the control inside the column in which it is positioned if the column is larger than the control. If the column is exactly as wide and high as the control itself, which is the typical case, then they do not have any visual effects - and also need not be defined.

align/valign do not affect the control's internal alignment.

Top of page

Binding to Adapter Properties

Most controls provide properties to specify the binding to the adapter processing. There is a naming convention, which is:

The type of the property which is referenced by a control depends on the control itself:

The type of the property is described with each control. See also Appendix C - Data Types to be Used by Adapter Properties.

Top of page

Directly Influencing the Control Style

All controls that incorporate textual information - such as labels, buttons or fields - offer the possibility to influence directly the style that is used for displaying the information.

The normal style is derived from the definition inside a cascading style definition file (file layout.css inside the html/general directory of the server). Overwrite or enhance this style information for your controls by passing the style information inside the corresponding style properties.

The properties specifying the style information end with the suffix "style", e.g. there is a property labelstyle for the label tag. The value of the property can be any kind of a valid HTML style specification. If you want to change the display style of a label to be large and blue, define the label in the following way:

<label name="Test" width="150" labelstyle="font-size: 24pt; color: #0000FF">
</label>

See Adapting the Look & Feel in the Special Development Topics for information on how to change the style of controls.

Top of page

Dynamically Controlling the Visibility and the Display Status of Controls

It is possible to influence the visibility of all input controls (FIELD, BUTTON, etc.) by properties of the adapter processing.

For some of these controls there is a property visibleprop, specifying an adapter property that returns "true" or "false". By this, you can control whether you want to display the control within the client or not.

Input controls support a property statusprop and a property displayprop. Using the corresponding adapter properties, you can dynamically control the display status of the input control. The adapter property for the statusprop can return the following values:

INVISIBLE
ERROR
ERROR_NO_FOCUS
FOCUS
FOCUS_NO_SELECT

The adapter property for the displayprop specifies whether the control is display-only (TRUE) or whether it can be edited (FALSE). The adapter property can return the values "TRUE" and "FALSE".

The combination of these two property values dynamically defines how the controls are rendered at runtime (for an example, see 80_displayprop in the cisdemos project). The following table defines the rendering of the control for the different combinations:

displayprop statusprop Control Status
FALSE (default) EDIT (deprecated) 1 EDIT
FALSE (default) INVISIBLE INVISIBLE
FALSE (default) ERROR ERROR
FALSE (default) ERROR_NO_FOCUS ERROR_NO_FOCUS
FALSE (default) FOCUS FOCUS
FALSE (default) FOCUS_NO_SELECT FOCUS_NO_SELECT
TRUE DISPLAY (deprecated) 1 DISPLAY
TRUE INVISIBLE INVISIBLE
TRUE ERROR ERROR_DISPLAY
TRUE ERROR_NO_FOCUS ERROR_DISPLAY
TRUE FOCUS DISPLAY
TRUE FOCUS_NO_SELECT DISPLAY

1 For statusprop, the above-mentioned deprecated values are still supported to ensure compatibility with older versions. In case you use these deprecated values for statusprop, the values for displayprop are ignored.

The literals used for the statusprop are available in the interface com.softwareag.cis.util.IControlStatusConstants:

package com.softwareag.cis.util;

public interface IControlStatusConstants
{
    public static final String CS_INVISIBLE = "INVISIBLE";
    public static final String CS_ERROR = "ERROR";
    public static final String CS_FOCUS = "FOCUS";
	   ...
}

The Adapter class from which you inherit your adapters supports this interface - consequently, you can directly use the CS_* constants inside your adapter implementations.

The generic com.softwareag.cis.server.Adapter class that you use as the base class for your adapter implementation already implements the IControlStatusConstants interface: you can directly use the constant definitions inside your adapter implementation.

The difference in behavior between "FOCUS" and "FOCUS_NO_SELECT" affects only the FIELD and TEXT controls. For these controls, FOCUS set the focus and selects the complete text inside the control. "FOCUS_NO_SELECT" sets the focus to the control, but does not select the text. For all other controls, "FOCUS_NO_SELECT" behaves like "FOCUS".

For all other controls - and for more complex manipulations of what is visible and not - use the possibility to be able to control the visibility of rows (ITR, TR) or containers (ROWAREA, ROWTABLE0): these controls provide for a visibility property and consequently can be switched on and off.

There is an extended management of what the control status "INVISIBLE" means. Most input controls (FIELD, CHECKBOX, etc.) supporting a statusprop or a visibleprop also support a property invisiblemode. The allowed values of invisiblemode are:

Top of page

Focus Management

Sometimes you want to control the keyboard focus inside a page. Here are the internal rules how a page finds out where to put the focus on.

The default reaction is - if a page is displayed for the first time - to put the focus on the first input control (FIELD, CHECKBOX, RADIOBUTTON, etc.) that is available inside a page. After that, you can navigate through the input controls - and the focus is kept stable when interacting with the server.

With statusprop - as mentioned in the previous section - you can interrupt this default reaction; there are two possibilities:

If several input controls are requesting the focus at the same time, the focus is put on the first corresponding input control.

A demo page is available in the standard Application Designer workplace showing an example of how to use the focus management:

graphics/image058.png

The XML layout definition for the first area "Focus Demo for Fields" looks as follows:

<rowarea name="Focus Demo for Fields">
    <itr>
        <label name="First Field" width="100">
        </label>
        <field valueprop="prop1" width="200" statusprop="prop1status">
        </field>
        <hdist width="30">
        </hdist>
        <button name="Set Focus" method="focus1">
        </button>
    </itr>
    <itr>
        <label name="Second Field" width="100">
        </label>
        <field valueprop="prop2" width="200" statusprop="prop2status">
        </field>
        <hdist width="30">
        </hdist>
        <button name="Set Focus" method="focus2">
        </button>
    </itr>
    <itr>
        <label name="Third Field" width="100">
        </label>
        <field valueprop="prop3" width="200" statusprop="prop3status">
        </field>
        <hdist width="30">
        </hdist>
        <button name="Set Focus" method="focus3">
        </button>
    </itr>
</rowarea>

In the demo, each field refers to a status property. The corresponding code of the adapter class looks as follows:

import com.softwareag.cis.server.Adapter;

// This class is a generated one.

public class FocusManagementAdapter
    extends Adapter
{
    // property >first<
    String m_first;
    public String getFirst() { return m_first; }
    public void setFirst(String value) { m_first = value; }

    // property >second<
    String m_second;
    public String getSecond() { return m_second; }
    public void setSecond(String value) { m_second = value; }

    // property >third<
    String m_third;
    public String getThird() { return m_third; }
    public void setThird(String value) { m_third = value; }

    // property >prop1<
    String m_prop1;
    public String getProp1() { return m_prop1; }
    public void setProp1(String value) { m_prop1 = value; }

    // property >prop1status<
    String m_prop1status;
    public String getProp1status() { return m_prop1status; }
    public void setProp1status(String value) { m_prop1status = value; }

    // property >prop2<
    String m_prop2;
    public String getProp2() { return m_prop2; }
    public void setProp2(String value) { m_prop2 = value; }

    // property >prop2status<
    String m_prop2status;
    public String getProp2status() { return m_prop2status; }
    public void setProp2status(String value) { m_prop2status = value; }

    // property >prop3<
    String m_prop3;
    public String getProp3() { return m_prop3; }
    public void setProp3(String value) { m_prop3 = value; }

    // property >prop3status<
    String m_prop3status;
    public String getProp3status() { return m_prop3status; }
    public void setProp3status(String value) { m_prop3status = value; }

    public void focus1() { m_prop1status = "FOCUS"; }
    public void focus2() { m_prop2status = "FOCUS"; }
    public void focus3() { m_prop3status = "FOCUS"; }

    /** start of data transfer */
    public void reactOnDataTransferStart()
    {
        super.reactOnDataTransferStart();
        // set default status of fields
        m_prop1status = "EDIT";
        m_prop2status = "EDIT";
        m_prop3status = "EDIT";
    }
}

Each time the page communicates with the adapter class, the focus information for all fields is reset to "default" inside the method reactOnDataTransferStart(). This method is called prior to any set/get operations by the Application Designer runtime.

By choosing a button, the corresponding focus method is called to set the status property to the value "FOCUS".

Top of page

Flushing of Inputs

Most input controls (FIELD, CHECKBOX, RADIOBUTTON, COMBOFIX, etc.) support a property named flush. This property controls whether data input from a user causes an immediate synchronisation with the server or whether data input from a user is stored internally within the client and is synchronized with the next flushing event (e.g. when choosing a button).

There are three different values that can be specified with the flush property:

Tip:
On the one hand, it is useful to flush information in a very fine granular way; you can react on wrong entered data immediately - on the other hand, you have to remember that each flush causes network traffic. The screen's data is sent to the server side processing and the screen waits for the response of the server. During this time, the page is blocked for input and the user sees an hour glass popping up in the left top corner of the screen.

Top of page

Tab Sequence

By default, the tab sequence of the controls of a page is defined by the order of the controls inside the page's XML layout definition. Using the property tabindex, this order can be overridden and the order of the tab index can be explicitly defined.

The following example shows a page with three fields and one button with an explicitly defined tab sequence:

graphics/image059.png

The XML layout definition is:

<rowarea name="Simple Tab Sequence">
    <itr takefullwidth="true">
        <coltable0 width="50%">
            <itr>
                <label name="First" width="120">
                </label>
                <field valueprop="first" width="120" tabindex="1">
                </field>
            </itr>
            <itr>
                <label name="Third" width="120">
                </label>
                <field valueprop="third" width="120" tabindex="3">
                </field>
            </itr>
        </coltable0>
        <coltable0 width="50%">
            <itr>
                <label name="Second" width="120">
                </label>
                <field valueprop="second" width="120" tabindex="2">
                </field>
            </itr>
            <itr>
                <hdist width="120">
                </hdist>
                <button name="OK" method="onOK" tabindex="4">
                </button>
            </itr>
        </coltable0>
    </itr>
</rowarea>

According to the sequence of controls inside the layout definition, the default tab sequence would be: field First, field Third, field Second and button OK.

Due to explicitly defining the tabindex property for the fields and the button, the tab sequence is now correct: field First, field Second, field Third and button OK.

Pay attention:

The tab index usually is a positive integer value. You may define tab index "-1" for excluding certain controls from the tab sequence at all. In this case, the corresponding controls may only be reached by mouse clicking.

Conclusion:

Top of page

Tooltips

Tooltips can be applied to many controls. If the user hovers with the mouse cursor over a control for some seconds, a small yellow box appears showing some more detailed explanation.

The corresponding controls offer two properties:

Top of page