With this session parameter, you can specify an edit mask for an input and/or output field that is used in one of the statements listed in the following table under Applicable statements.
Possible settings | See EM Parameter Syntax. | |
---|---|---|
Default setting | none | |
Applicable statements | FORMAT |
Parameter may be specified dynamically with the
FORMAT statement.
|
|
Parameter may be specified at statement level and/or at element level. | |
MOVE
EDITED |
Parameter may be specified at element level. | |
Applicable command | none |
Notes:
EMU
.
EM
can also be used with U
format fields. For information on Unicode format, see
Unicode and
Code Page Support in the Natural Programming Language,
Session Parameters,
EMU
, ICU
,
LCU
, TCU
versus
EM
, IC
,
LC
, TC
.
The following topics are covered below:
For input fields, values must be entered exactly matching the edit mask.
If you would like to display the edit mask for an input field, the field should
be defined as modifiable (AD=M
).
For a database field, a default edit mask may have been defined in the
DDM. If you specify with the EM
parameter an edit mask
for a database field, this edit mask specified will be used instead of any
default edit mask which may be defined for the field in the DDM.
If you specify EM=OFF
for a field, no edit mask will be
used for the field, not even one that may be defined in the DDM.
At statement level of a DISPLAY
,
FORMAT
,
INPUT
or
WRITE
statement, no
detail field edit mask may be specified, except EM=OFF
.
An edit mask overrides any settings for the session parameters
AL
,
NL
and
SG
.
The characters 9
, H
, X
and
Z
represent significant print positions in numeric
(9,Z
), hexadecimal (H
), and alphanumeric
(X
) edit masks. For the difference between 9
and
Z
, see Edit Masks for Numeric
Fields, below.
DISPLAY AA(EM=OFF) AB(EM=XX.XX) WRITE SALARY (EM=ZZZ,ZZ9)
You may replace a sequence of the same significant characters with a
numeric notation, such as x(8)
for xxxxxxxx
. The
following examples demonstrate the abbreviated notation which may be used for
the significant characters of numeric (Z,9
), hexadecimal
(H
), alphanumeric (X
) and date (N,L
)
edit masks:
EM=9(4)-9(5) is equivalent to: EM=9999-99999 EM=H(10) is equivalent to: EM=HHHHHHHHHH EM=X(6)..X(3) is equivalent to: EM=XXXXXX..XXX EM=YYYY-L(8)-DD-N(8) is equivalent to: EM=YYYY-LLLLLLLL-DD-NNNNNNNN
Blanks behind the equal sign (=) of the EM
parameter are not allowed (for example: EM=<blank>XXX
).
Blanks within an edit mask are represented by the character on your
keyboard that in hexadecimal code corresponds to H'20'
(ASCII) or
H'5F'
(EBCDIC), that is, the character ^
(or
¬
).
If no edit mask is specified for a field, a default edit mask is assigned to the field depending on the field format:
Field Format | Default Edit Mask |
---|---|
A | X |
B | H |
N, P, I | Z9 |
F | scientific representation |
D | depends on default date format (as set with the profile
parameter DTFORM )
|
T | HH:II:SS |
L | blank / X |
An edit mask specified for a field of format N, P, I, or F must contain
at least one 9
or Z
.
If more 9
s or Z
s exist than the number of
positions contained in the field value, the number of print positions in the
edit mask will be adjusted to the number of digits defined for the field
value.
If fewer 9
s or Z
s exist, the high-order digits
before the decimal separator and/or low-order digits after the decimal
separator will be truncated.
The following topics are covered below:
Character | Function |
---|---|
9 |
Position to be displayed (one digit of the field value). |
. (period)
|
The first period inserted is used as a decimal separator.
Subsequent periods are treated as literal characters.
Note: |
Z |
Zero suppression for leading zeros. This is the default for
numeric fields. The letter Z may be repeatedly specified to
represent floating zero suppression. Z must not be specified to
the right of the decimal separator character. A zero value may be displayed as
blanks using all Z s in the edit mask (see also the session
parameter ZP ).
|
The 9
s or Z
s can be preceded by one or more
other characters.
If the first character before the 9
s or Z
s is
+
, -
, S
or N
, a sign may be
displayed:
Character | Function |
---|---|
+ |
A floating sign is to be displayed preceding (leading sign character) or following (trailing sign character) the number. The sign may be generated as a plus or minus depending on the value of the field. |
- |
A floating minus is to be displayed preceding (leading sign character) or following (trailing sign character) the number if the value of the field is negative. |
S |
A sign is to be displayed to the left of the column. A plus sign is displayed for a positive value and a minus sign is displayed for a negative value. |
N |
A minus sign is to be displayed to the left of the column if the value of the field is negative. |
Any number of literal leading characters can appear before the first
displayable position (as indicated by Z
or 9
). These
must follow any sign character. If there is no sign character and the first
literal leading character is +
, -
, S
or
N
, it must be enclosed in apostrophes. If a literal leading
character is H
, X
, Z
or 9
,
it must be enclosed in apostrophes.
The first literal leading character specified will appear in the output only if the value contains leading zeros and the edit mask is defined with Z (leading zero suppression). This character will then be used as a filler character displayed instead of a blank for leading zeros. Subsequent literal leading characters will be displayed as they are input.
Literal insertion and trailing characters can also be used. The symbol
(^
) can be used to represent a leading, inserted, or trailing
blank. By enclosing significant characters (9
, H
,
Z
, X
) in apostrophes, it is possible to use any
characters as leading, insertion, or trailing characters. Insignificant edit
mask characters need not be enclosed in apostrophes. Within the same edit mask
notation, it is possible to have groups of leading, insertion, and/or trailing
character strings, some of which are bounded by apostrophes and some of which
are not.
A trailing sign character can be specified for numeric edit masks by
using the +
or -
character as the last character in
the edit mask. A +
will produce a trailing +
or
-
sign depending on the value of the field. A -
will
produce a trailing space or -
sign depending on the value of the
field. If a leading and trailing sign are specified in the edit mask, both will
be produced.
The table below lists the results obtained from the original values shown at the top of each column as they are output without editing mask. All values used as column headings represent format N fields. The lines below the top column represent the formats obtained using the different editing masks:
Value | 0000.03 (N4.2) |
-0054 (N4) |
+0087 (N4) |
0962 (N4) |
1830 (N4) |
---|---|---|---|---|---|
Edit Mask | |||||
EM=9.9 |
0.0 |
4. |
7. |
2. |
0. |
EM=99 |
00 |
54 |
87 |
62 |
30 |
EM=S99 |
+00 |
-54 |
+87 |
+62 |
+30 |
EM=+Z9 |
+0 |
-54 |
+87 |
+62 |
+30 |
EM=-9.99 |
0.03 |
-4. |
7. |
2. |
0. |
EM=N9 |
0 |
-4 |
7 |
2 |
0 |
EM=*9.99 |
0.03 |
4. |
7. |
2. |
0. |
EM=Z99 |
00 |
54 |
87 |
962 |
830 |
EM=*EURZZ9.9 |
EUR**0.0 |
EUR*54. |
EUR*87. |
EUR962. |
EUR830. |
EM=999+ |
000+ |
054- |
087+ |
962+ |
830+ |
EM=999- |
000 |
054- |
087 |
962 |
830 |
IC=$ EM=ZZZ.99 |
$.03 |
$54. |
$87. |
$962. |
$830. |
EM=H(6) |
|||||
- ASCII: | 303030303033 |
30303574 |
30303837 |
30393632 |
31383330 |
- EBCDIC: | F0F0F0F0F0F3 |
F0F0F5D4 |
F0F0F8F7 |
F0F9F6F2 |
F1F8F3F0 |
By combining edit masks with the parameters IC
and TC
, negative numbers can be displayed in varying
formats using a DISPLAY
statement.
An alphanumeric edit mask which is only to be used with A format fields
must contain at least one X
which represents a character to be
displayed. An H
as the first character designates a
hexadecimal edit
mask. A blank is represented by a (^
) symbol. All other
characters except closing parentheses are permissible including leading,
trailing, and insertion characters. It is also possible to specify leading,
insertion, or trailing characters enclosed within apostrophes. If the character
X
, a closing parenthesis, or a quotation mark is specified as an
insertion character, it must be enclosed within apostrophes.
If leading characters are used before the first displayable position
X
of an alphanumeric edit mask, the first of these leading
characters will not be displayed, but is used as filler character and replaces
all leading blanks in the alphanumeric output field.
DEFINE DATA LOCAL 1 #X (A4) INIT <' 34'> END-DEFINE WRITE #X (EM=*A:X:) 6X #X (EM=*A:XX:) 6X #X (EM=*A:XXX:) 6X #X (EM=*A:XXXX:) 6X #X (EM=1234XXXX5678) END
A:*: A:**: A:**3: A:**34: 23411345678
Trailing characters which immediately follow the last permissible print position will be displayed.
If the number of positions specified with the mask is smaller than the field length, the overhanging field content is not displayed.
If the number of positions specified with the mask is higher than the field length, the mask is truncated on the first overhanging position.
DEFINE DATA LOCAL 1 #TEXT (A4) INIT <'BLUE'> END-DEFINE WRITE #TEXT (EM=X-X-X) /* 'B-L-U', 3 bytes of field only. WRITE #TEXT (EM=X-X-X-X-X) /* 'B-L-U-E-', with truncated mask. END
The following program lists the alphanumeric edit masks for a field
that is defined with format/length A4 and contains the value
BLUE
.
** Example 'EMMASK1': Edit mask ************************************************************************ DEFINE DATA LOCAL 1 #TEXT (A4) END-DEFINE * ASSIGN #TEXT = 'BLUE' WRITE NOTITLE 'MASK 1:' 5X #TEXT (EM=X.X.X.X) / 'MASK 2:' 5X #TEXT (EM=X^X^X^X) / 'MASK 3:' 5X #TEXT (EM=X--X--X) / 'MASK 4:' 5X #TEXT (EM=X-X-X-X-X-X) / 'MASK 5:' 5X #TEXT (EM=X' 'X' 'X' 'X) / 'MASK 6:' 5X #TEXT (EM=XX....XXX) / 'MASK 7:' 5X #TEXT (EM=1234XXXX) END
Output of Program EMMASK1
:
MASK 1: B.L.U.E MASK 2: B L U E MASK 3: B--L--U MASK 4: B-L-U-E- MASK 5: B L U E MASK 6: BL....UE MASK 7: 234BLUE
Edit masks for binary fields may be set using X
or
H
notation. For binary fields, the X
notation is
supported as if H
had been specified instead of
X
.
If the character H
is specified as the first character in
an edit mask, the content of an alphanumeric or numeric field will be displayed
in hexadecimal format. Each H
represents two print positions that
will occur for each byte in the source field. Characters other than
H
serve as insertion or trailing characters in the mask. The
number of positions to be displayed will be adjusted to the length of the edit
mask if the mask is shorter than the field. The length of the edit mask will be
adjusted to the length of the field if the field length is shorter than the
edit mask.
Insertion or trailing characters may be optionally specified bounded by apostrophes.
All fields displayed with a hexadecimal edit mask are treated as alphanumeric. Therefore, if the edit mask is shorter than the field to be edited, numeric or alphanumeric positions will be displayed from left to right disregarding any decimal separator positions.
If a hexadecimal edit mask is used as an input edit mask, every
0-9
, a-f,
A-F
, blank and hex zero are
accepted as a hex digit.
Note:
Blank and hex zero are regarded as 0
and a lower-case
letter (a-f
) is regarded as an upper-case letter.
The tables below list the hexadecimal edit masks with results obtained
from the original fields and values shown above each column. All numeric values
(-10
, +10
, 01
) to which edit masks have
been applied originated in fields defined with N2 format. The alphanumeric
value AB
originated from a field defined with format/length
A2.
Value => | AB |
-10 |
+10 |
01 |
EM=HH |
4142 |
3170 |
3130 |
3031 |
EM=H^H |
41 42 |
31 70 |
31 30 |
30 31 |
EM=HH^H |
4142 |
3170 |
3130 |
3031 |
EM=H-H |
41-42 |
31-70 |
31-30 |
30-31 |
EM=H |
41 |
31 |
31 |
30 |
Value => | AB |
-10 |
+10 |
01 |
EM=HH |
C1C2 |
F1D0 |
F1F0 |
F0F1 |
EM=H:H |
C1 C2 |
F1 D0 |
F1 F0 |
F0 F1 |
EM=HH:H |
C1C2 |
F1D0 |
F1F0 |
F0F1 |
EM=H-H |
C1-C2 |
F1-D0 |
F1-F0 |
F0-F1 |
EM=H |
C1 |
F1 |
F1 |
F0 |
** Example 'EMMASK2': Edit mask ************************************************************************ DEFINE DATA LOCAL 1 #TEXT1 (A2) 1 #TEXT2 (N2) END-DEFINE * ASSIGN #TEXT1 = 'AB' ASSIGN #TEXT2 = 10 * WRITE NOTITLE 'MASK (EM=HH) :' 18T #TEXT1 (EM=HH) 30T #TEXT2 (EM=HH) / 'MASK (EM=H^H) :' 18T #TEXT1 (EM=H^H) 30T #TEXT2 (EM=H^H) / 'MASK (EM=HH^H):' 18T #TEXT1 (EM=HH^H) 30T #TEXT2 (EM=HH^H) / 'MASK (EM=H-H) :' 18T #TEXT1 (EM=H-H) 30T #TEXT2 (EM=H-H) / 'MASK (EM=H) :' 18T #TEXT1 (EM=H) 30T #TEXT2 (EM=H) END
Output of Program EMMASK2
(ASCII):
MASK (EM=HH) : 4142 3130 MASK (EM=H^H) : 41 42 31 30 MASK (EM=HH^H): 4142 3130 MASK (EM=H-H) : 41-42 31-30 MASK (EM=H) : 41 31
Output of Program EMMASK2
(EBCDIC):
MASK (EM=HH) : C1C2 F1F0 MASK (EM=H^H) : C1 C2 F1 F0 MASK (EM=HH^H): C1C2 F1F0 MASK (EM=H-H) : C1-C2 F1-F0 MASK (EM=H) : C1 F1
In edit masks for fields which are defined with format D (date) or T (time), the characters described in the following sections can be specified.
Character | Usage |
---|---|
DD |
Day. |
ZD |
Day, with zero suppression. |
MM |
Month. |
ZM |
Month, with zero suppression. |
YYYY |
Year, 4 digits (see the section Hints for Input Edit Mask). |
YY |
Year, 2 digits (see the section Hints for Input Edit Mask). |
Y |
Year, 1 digit. Must not be used for input fields. |
WW |
Number of week (see the sections Hints for Input Edit Mask and Hints for Week Display in Output Edit Mask). |
ZW |
Number of week, with zero suppression (see the sections Hints for Input Edit Mask and Hints for Week Display in Output Edit Mask). |
JJJ |
Julian day. |
ZZJ |
Julian day with zero suppression. |
NN... or
N(n) |
Name of day (language-dependent). The maximum length is
determined by the number of N s or by n.
If the name is longer than the maximum length, it will be truncated; if it is
shorter, the actual length of the name will be used.
|
O |
Number of week day. The profile parameter
DTFORM determines
whether Monday or Sunday is considered the first day of the week. With
DTFORM=U : (Sunday = 1, Monday = 2, etc.). With
DTFORM=other : (Monday = 1, Tuesday = 2,
etc.).
|
LL... or
L(n) |
Name of month (language-dependent). The maximum length is determined by the number of L characters or by n. If the name is longer than the maximum length, it will be truncated; if it is shorter, the actual length of the name will be used. |
R |
Year in Roman numerals (maximum 13 digits). Must not be used for input fields. |
For Input and Output edit masks, you may not use the following:
text | characters | ||||
---|---|---|---|---|---|
month | with | month name | MM or ZM |
with | LL or
L(n) |
day name | with | week day number | NN or
N(n) |
with | O |
For Input edit masks, you may not use the following:
text | characters | ||||
---|---|---|---|---|---|
1-digit year | nor | a year in Roman numerals | Y |
nor | R |
Day | without | month or month name | DD or ZD |
without | MM or ZM or
LL or L(n) |
Week | without | year | WW or ZW |
without | YYYY or YY |
Month | without | year | MM or ZM |
without | YYYY or YY |
Julian day | without | year | JJJ or ZZJ |
without | YYYY or YY |
Day name | without | week | NN or
N(n) |
without | WW or ZW |
Week day number | without | week | O |
without | WW or ZW |
Julian day | with | month | JJJ or ZZJ |
with | MM or ZM |
Julian day | with | week | JJJ or ZZJ |
with | WW or ZW |
Month | with | week | MM or ZM |
with | WW or ZW |
The range of valid year values (YYYY
) is 1582 -
2699
. If the profile parameter MAXYEAR
is set to
9999
, the range of valid year values is 1582 - 9999
.
If only year (YY
or YYYY
) but no month or day
is specified within an input edit mask, the values for month and day will both
be set to 01
. If only year (YY
or YYYY
)
and month (MM
) but no day is specified within an input edit mask,
the value for day will be set to 01
.
If a 2-digits year (YY
) is used, the century used to fill
up the year representation is the current century by default. However, this
does not apply when a Sliding or Fixed Window is set. For more details, refer
to profile parameter YSLW
in
the Parameter Reference documentation.
If a week number (WW
or ZW
) but no number of
week day (O
) or name of day (NN...
) is specified, the
first day of the week is assumed.
When DTFORM=U
(USA format) is set, the week starts on
Sunday; whereas for all other DTFORM
settings the first
weekday is Monday. Whether a week is week 52/53 of the old year or week 01 of
the new year depends on which year contains more days of the week. In other
words, if Thursday (Wednesday for DTFORM=U
) of that week is in the
previous year, the week belongs to the previous year; if it is in the next
year, the week belongs to the next year.
If the number of week (WW
or ZW
) and a year
representation (YYYY
or YY
or Y
) is in
the same edit mask, the display for year always corresponds to the week number,
regardless of the year in the underlying date field.
DEFINE DATA LOCAL 1 D (D) END-DEFINE MOVE EDITED '31-12-2003' TO D(EM=DD-MM-YYYY) DISPLAY D(EM=DD-MM-YYYY_N(10)) D(EM=DD-MM-YYYY/WW) END
Although the underlying date is the 31 Dec. 2003, when the week number
WW
is contained in the edit mask, it displays as:
D D -------------------- ------------- 31-12-2003_Wednesday 31-12-2004/01
Character | Usage |
---|---|
T |
Tenths of a second. |
SS |
Seconds. |
ZS |
Seconds, with zero suppression. |
II |
Minutes. |
ZI |
Minutes, with zero suppression. |
HH |
Hours. |
ZH |
Hours, with zero suppression. |
AP |
AM/PM element. |
** Example 'EMDATI': Edit mask for date and time variables ************************************************************************ * WRITE NOTITLE 'DATE INTERNAL :' *DATX (DF=L) / ' :' *DATX (EM=N(9)' 'ZW.'WEEK 'YYYY) / ' :' *DATX (EM=ZZJ'.DAY 'YYYY) / ' ROMAN :' *DATX (EM=R) / ' AMERICAN :' *DATX (EM=MM/DD/YYYY) 12X 'OR ' *DAT4U / ' JULIAN :' *DATX (EM=YYYYJJJ) 15X 'OR ' *DAT4J / ' GREGORIAN:' *DATX (EM=ZD.''L(10)''YYYY) 5X 'OR ' *DATG /// * 'TIME INTERNAL :' *TIMX 14X 'OR ' *TIME / ' :' *TIMX (EM=HH.II.SS.T) / ' :' *TIMX (EM=HH.II.SS' 'AP) / ' :' *TIMX (EM=HH) END
Output of Program EMDATI
:
DATE INTERNAL : 2005-01-12 : Wednesday 2.WEEK 2005 : 12.DAY 2005 ROMAN : MMV AMERICAN : 01/12/2005 OR 01/12/2005 JULIAN : 2005012 OR 2005012 GREGORIAN: 12.January2005 OR 12January 2005 TIME INTERNAL : 16:04:14 OR 16:04:14.8 : 16.04.14.8 : 04.04.14 PM : 16
For fields of format L (logical fields), edit masks can be defined as follows:
(EM =[false-string/]true-string)
|
The false-string must not be longer than 31 characters.
** Example 'EMLOGV': Edit mask for logical variables ************************************************************************ DEFINE DATA LOCAL 1 #SWITCH (L) INIT <true> 1 #INDEX (I1) END-DEFINE * FOR #INDEX 1 5 WRITE NOTITLE #SWITCH (EM=FALSE/TRUE) 5X 'INDEX =' #INDEX WRITE NOTITLE #SWITCH (EM=OFF/ON) 7X 'INDEX =' #INDEX IF #SWITCH MOVE FALSE TO #SWITCH ELSE MOVE TRUE TO #SWITCH END-IF /* SKIP 1 END-FOR END
Output of Program EMLOGV
:
TRUE INDEX = 1 ON INDEX = 1 FALSE INDEX = 2 OFF INDEX = 2 TRUE INDEX = 3 ON INDEX = 3 FALSE INDEX = 4 OFF INDEX = 4 TRUE INDEX = 5 ON INDEX = 5