This Natural profile parameter can be used to predefine the properties
for external programs. It corresponds to the
NTPGP
macro
in the Natural parameter module.
Possible settings | See PGP Parameter Syntax. | |
---|---|---|
Default setting | OFF |
No properties are defined for external programs. |
Dynamic specification | yes | The profile parameter PGP can only be
specified dynamically. In the
Natural
parameter module, the macro
NTPGP must
be used.
|
Specification within session | yes | Temporary SET CONTROL
'P=value' for each call of the external
program.
|
Notes:
CALL
statement, there
are already several options available by means of a preceding
SET CONTROL
statement (for example, SET CONTROL 'P=S'
) to request certain
programming interface properties for the subsequent CALL
. With
NTPGP
or PGP
it is possible to
predefine these program properties in the Natural parameter module or
dynamically rather than in the Natural application program, which could be
error prone
PGP
definitions for different
programs, PGP
or NTPGP
must be
specified multiple times.
%P=
applies only
to the next call of an external program, and the call options are reset
unconditionally on return from the call, whereas the profile parameter
PGP
sets the call option for an external program
permanently.
PGP
or by a SET CONTROL
'P=value'
statement, these properties will be
merged for this program.
With the dynamic PGP
parameter, you first specify the
program name, and then one or more properties for this program.
PGP=(program-name,property-1,property-2,...) |
Or:
PGP=OFF |
Notes:
OFF
resets all properties for the
program previously defined.
PGP
definitions for
different programs, the profile parameter PGP
must be
specified multiple times (separated by a comma or a blank).
Property | Short | Explanation | SET CONTROL |
---|---|---|---|
STDL |
S |
Standard linkage under CICS | P=S |
STDLC |
SC |
Standard linkage simulates EXEC
CICS LINK .
|
P=SC |
ROLL |
V |
Rollout for call in thread environments. | P=V |
COMA |
C |
Pass values in CICS COMMAREA. | P=C |
CONT
|
CC |
Pass parameter values in CICS container. | P=CC |
LEMAIN
|
L |
The called program is an IBM LE main program. | P=L |
LESUB |
LS |
The called program is an IBM LE subprogram (IBM only) . | P=LS |
IMSPCB |
I |
Pass the IBM IMS/DC PCB address. | P=I |
DIGR
|
D |
The called program is a DIGNUS remote subprogram. | P=D |
DIGL |
DL |
The called program is a DIGNUS local subprogram. | P=DL |
SUOW
|
U |
SUOW, separate CICS unit of work. | P=U |
SUOWB
|
UT |
Separate CICS unit of work tolerate backout. | P=UT |
OFF |
Clear all properties previously defined (dynamic parameter specification only). |
With the NTPGP
macro in the
Natural
parameter module, you first specify the name of the external program
and then one or more properties for this program.
NTPGP program-name,property-1,property-2,...
Notes:
NTPGP
correspond to that of profile parameter PGP
, see
Syntax
Elements and Property Values.
OFF
cannot be set with the macro
NTPGP
.
NTPGP
must be specified multiple times.
PGP=(TESTPGM1,S) PGP=(’ABX*’,L,NOS) PGP=(MYPROG7,OFF,L,STDL)
NTPGP TESTPGM1,S NTPGP ABX*,L NTPGP MYPROG,L,STDL