Text |
No ... database handler available. |
Expl. |
A specific database handler is assigned to handle the database. However, the database handler requested is not available. Possible reason are: - the database handler module isn"t linked to Natural - the session profile parameter for the buffer size of the database handler is zero - an error occurred during initialization of the database handler - the wrong database handler has been specified for the database, either by macro NTDB in the parameter module or by the DB parameter |
Actn. |
Depends on the reason of the error. If an initialization error had occurred, check the session initialization error messages. |
Text |
NAT object STOWed for ... but executed under .... |
Expl. |
The DBID used when stowing the Natural object is assigned to database type .1. but at runtime this DBID is assigned to database type .2. |
Actn. |
The DBID used at stow time and at runtime must be assigned to the same database type. |
Text |
Unknown DB response code .... DB/FNR/Subcode .../.../.... |
Expl. |
An unknown response code was received from the Adabas interface. |
Actn. |
Check program and correct error. |
Text |
ADAMODE was changed from :1: to :2:. |
Expl. |
Natural was started with ADAMODE=:1:. This mode is not supported by the database, or Natural could not allocate the resources required to execute in this mode. Natural has switched automatically to ADAMODE=:2:. The original error message, the technical reason, was issued prior to this message, and can be viewed with the LASTMSG command. |
Actn. |
Contact your Natural/Adabas administrator. |
Text |
No Natural ICU handler available. |
Expl. |
The Natural ICU handler is not available. Possible reasons are: - The ICU handler module is not linked to Natural or cannot be loaded. - The session profile parameter CFICU is set to OFF. - An error occurred during the initialization of the Natural ICU. |
Actn. |
Depends on the reason of the error. If an initialization error has occurred, check the session initialization error messages. |
Text |
Code page ... not available. |
Expl. |
ICU (International Components for Unicode) is the engine to support code pages and Unicode in Natural. Code pages are defined in ICU in a data file that is linked to the nucleus or loaded dynamically. If the code page is not available, it is not part of the data file used. |
Actn. |
Please contact Software AG support. |
Text |
Internal error from ICU: .... |
Expl. |
ICU (International Components for Unicode) is the engine to support code pages and Unicode in Natural. Possible reasons for internal errors of ICU are: - memory allocation errors, - internal program errors, - corrupted definition files of converters, - missing resources in data files. |
Actn. |
Please contact Software AG support. |
Text |
Conversion error, at least 1 code point not translated. H".." |
Expl. |
If, during Unicode conversion or the conversion from one code page to another, a code point or character cannot be converted to the desired destination code page, a code-page-specific substitution character is used instead. The generation of this message depends on the CPCVERR=ON/OFF option in the SET GLOBALS statement. The first failed code point of the source string is displayed in hexadecimal format at the end of the message. |
Actn. |
Check the content of the input/target field of the conversion. |
Text |
Reserved for ICU. |
Text |
Conversion result is truncated. |
Expl. |
During Unicode conversion or the conversion from one code page to another, the result in the target field has been truncated. |
Actn. |
Check the length of the target field. |
Text |
Length/format of operand is incompatible with code page. |
Expl. |
For a Unicode conversion, or a conversion from one code page to another, the format and length of source/target fields must be compatible with the corresponding code page. Example 1: The source/target field is defined as (Bn), but the value of <minimum bytes per code point> of the relevant code page is > n; this means that not even one code point could be stored in the field. Example 2: For many code points, the minimum and maximum bytes per code point are identical. Before the conversion, it is checked whether the code points fit into the defined length. If they do not, this message is issued. This is to avoid the truncation of code point values. |
Actn. |
Check the lengths of the source and target operands. |
Text |
The used code page name is ambiguous in this context. |
Expl. |
The target code page specified in MOVE ENCODED statement must be unambiguous. However, specifying "UTF-16" or "UTF-32" does not uniquely identify a target code page. |
Actn. |
Instead of "UTF-16" and "UTF-32", specify "UTF-16BE" or "UTF-16LE", and "UTF-32BE" or "UTF-32LE" respectively. |
Text |
ICU Data Library ... cannot be loaded (...). |
Expl. |
The data library is treated like an external program. The specified external data library could be neither loaded dynamically nor located statically. See the supplied operating-system/TP-monitor return code of the failing LOAD request for details. Possible reasons: - The data library to be loaded dynamically is not contained in the load libraries currently defined to Natural. - Under CICS: The data library is not defined to CICS. - There was not enough storage available to load the data library dynamically (under Com-plete: the Com-plete thread was too small). - The CDYNAM limit for dynamically loaded programs was exceeded. - The DATFILE version is not compatible with SAGICU (reason 80). - For static data library: The data library is not defined in NATPARM with the CSTATIC parameter or not linked to the NATPARM module. |
Actn. |
with the CSTATIC parameter or not linked to the NATPARM module. Make sure that the data library is contained in a library available to or linked to Natural. Contact your Natural administrator concerning the setting of the Natural profile parameters CDYNAM and CSTATIC. |
Text |
Local ICU buffer pool cannot be used. RC=... |
Expl. |
The message is displayed at session start if the local ICU buffer pool cannot be used. The reason code (RC) indicates the reason for this message: RC=1 - Local ICU buffer pool is not available. RC=2 - Local ICU buffer pool is too small. RC=3 - Local ICU buffer pool is already used by a different ICU nucleus. If CFICU subparameter BPONLY=ON, the message leads to a termination of the ICU initialization with the consequence that no ICU handler is available for the current Natural session. If CFICU subparameter BPONLY=OFF, the required buffers are allocated in the Natural thread. |
Actn. |
Make the local ICU buffer pool available, or increase its size. |
Text |
Maximum line length exceeded in line .... |
Expl. |
The source area has Unicode UTF-16 format. When you save a source, it is converted from UTF-16 to the source encoding, which can change the size (in code points) of a character. This error occurs because the current source contains a line which, after the conversion, exceeds the maximum line length. |
Actn. |
Either split the line or choose another encoding for saving the source. |