Natural for Mainframes Version 8.2.6 for Mainframes
 —  Programming Guide  —

Rules for Arithmetic Assignment

This document covers the following topics:


Field Initialization

A field (user-defined variable or database field) which is to be used as an operand in an arithmetic operation must be defined with one of the following formats:

Format
N Numeric unpacked
P Packed numeric
I Integer
F Floating point
D Date
T Time

Note:
For reporting mode: A field which is to be used as an operand in an arithmetic operation must have been previously defined. A user-defined variable or database field used as a result field in an arithmetic operation need not have been previously defined.

All user-defined variables and all database fields defined in a DEFINE DATA statement are initialized to the appropriate zero or blank value when the program is invoked for execution.

Top of page

Data Transfer

Data transfer is performed with a MOVE or COMPUTE statement. The following table summarizes the data transfer compatibility of the formats an operand may take.

Sending Field Format Receiving Field Format
N or P A U Bn (n<5) Bn (n>4) I L C D T F G O
N or P Y [ 2 ] [ 14 ] [ 3 ] - Y - - - Y Y - -
A - Y [ 13 ] [ 1 ] [ 1 ] - - - - - - - -
U - [ 11 ] Y [ 12 ] [ 12 ] - - - - - - - -
Bn (n<5) [ 4 ] [ 2 ] [ 14 ] [ 5 ] [ 5 ] Y - - - Y Y - -
Bn (n>4) - [ 6 ] [ 15 ] [ 5 ] [ 5 ] - - - - - - - -
I Y [ 2 ] [ 14 ] [ 3 ] - Y - - - Y Y - -
L - [ 9 ] [ 16 ] - - - Y - - - - - -
C - - - - - - - Y - - - - -
D Y [ 9 ] [ 16 ] Y - Y - - Y [7] Y - -
T Y [ 9 ] [ 16 ] Y - Y - - [ 8 ] Y Y - -
F Y [ 9 ] [ 10 ] [ 10 ] [ 16 ] [ 3 ] - Y - - - Y Y - -
G - - - - - - - - - - - Y -
O - - - - - - - - - - - - Y

Where:

Y Indicates data transfer compatibility.
- Indicates data transfer incompatibility.
[ ] Numbers in brackets [ ] refer to the corresponding rule for data transfer given below.

Data Conversion

The following rules apply to converting data values:

  1. Alphanumeric to binary:
    The value will be moved byte by byte from left to right. The result may be truncated or padded with trailing blank characters depending on the length defined and the number of bytes specified.

  2. (N,P,I) and binary (length 1-4) to alphanumeric:
    The value will be converted to unpacked form and moved into the alphanumeric field left justified, that is, leading zeros will be suppressed and the field will be filled with trailing blank characters. For negative numeric values, the sign will be converted to the hexadecimal notation Dx. Any decimal point in the numeric value will be ignored. All digits before and after the decimal point will be treated as one integer value.

  3. (N,P,I,F) to binary (1-4 bytes):
    The numeric value will be converted to binary (4 bytes). Any decimal point in the numeric value will be ignored (the digits of the value before and after the decimal point will be treated as an integer value). The resulting binary number will be positive or a two's complement of the number depending on the sign of the value.

  4. Binary (1-4 bytes) to numeric:
    The value will be converted and assigned to the numeric value right justified, that is, with leading zeros. (Binary values of the length 1-3 bytes are always assumed to have a positive sign. For binary values of 4 bytes, the leftmost bit determines the sign of the number: 1=negative, 0=positive.) Any decimal point in the receiving numeric value will be ignored. All digits before and after the decimal point will be treated as one integer value.

  5. Binary to binary:
    The value will be moved from right to left byte by byte. Leading binary zeros will be inserted into the receiving field.

  6. Binary (>4 bytes) to alphanumeric:
    The value will be moved byte by byte from left to right. The result may be truncated or padded with trailing blanks depending on the length defined and the number of bytes specified.

  7. Date (D) to time (T):
    If date is moved to time, it is converted to time assuming time 00:00:00:0.

  8. Time (T) to date (D):
    If time is moved to date, the time information is truncated, leaving only the date information.

  9. L,D,T,F to A:
    The values are converted to display form and are assigned left justified.

  10. F:
    If F is assigned to an alphanumeric or Unicode field which is too short, the mantissa is reduced accordingly.

  11. Unicode to alphanumeric:
    The Unicode value will be converted to alphanumeric character codes according to the default code page (value of the system variable *CODEPAGE) using the International Components for Unicode (ICU) library. The result may be truncated or padded with trailing blank characters, depending on the length defined and the number of bytes specified. If the characters of the Unicode value are not defined in the default code page, a runtime error is output or the characters are replaced with the substitution character, depending on the setting of the profile/session parameter CPCVERR.

  12. Unicode to binary:
    The value will be moved code unit by code unit from left to right. The result may be truncated or padded with trailing blank characters, depending on the length defined and the number of bytes specified. The length of the receiving binary field must be even.

  13. Alphanumeric to Unicode:
    The alphanumeric value will be converted from the default code page to a Unicode value using the International Components for Unicode (ICU) library. The result may be truncated or padded with trailing blank characters, depending on the length defined and the number of code units specified.

  14. (N,P,I) and binary (length 1-4) to Unicode:
    The value will be converted to unpacked form from which an alphanumeric value will be obtained by suppression of leading zeros. For negative numeric values, the sign will be converted to the hexadecimal notation Dx. Any decimal point in the numeric value will be ignored. All digits before and after the decimal point will be treated as one integer value. The resulting value will be converted from alphanumeric to Unicode. The result may be truncated or padded with trailing blank characters, depending on the length defined and the number of code units specified.

  15. Binary (>4 bytes) to Unicode:
    The value will be moved byte by byte from left to right. The result may be truncated or padded with trailing blanks, depending on the length defined and the number of bytes specified. The length of the sending binary field must be even.

  16. L,D,T,F to U:
    The values are converted to an alphanumeric display form. The resulting value will be converted from alphanumeric to Unicode and assigned left justified.

If source and target format are identical, the result may be truncated or padded with trailing blank characters (format A and U) or leading binary zeros (format B) depending on the length defined and the number of bytes (format A and B) or code units (format U) specified.

See also Using Dynamic Variables.

Top of page

Field Truncation and Field Rounding

The following rules apply to field truncation and rounding:

Top of page

Result Format and Length in Arithmetic Operations

The following table shows the format and length of the result of an arithmetic operation:

  I1 I2 I4 N or P F4 F8
I1 I1 I2 I4 P* F4 F8
I2 I2 I2 I4 P* F4 F8
I4 I4 I4 I4 P* F4 F8
N or P P* P* P* P* F4 F8
F4 F4 F4 F4 F4 F4 F8
F8 F8 F8 F8 F8 F8 F8

On a mainframe computer, format/length F8 is used instead of F4 for improved precision of the results of an arithmetic operation.

P* is determined from the integer length and precision of the operands individually for each operation, as shown under Precision of Results of Arithmetic Operations.

The following decimal integer lengths and possible values are applicable for format I:

Format/Length Decimal Integer Length Possible Values
I1 3 -128 to 127
I2 5 -32768 to 32767
I4 10 -2147483648 to 2147483647

Top of page

Arithmetic Operations with Floating-Point Numbers

The following topics are covered below:

General Considerations

Floating-point numbers (format F) are represented as a sum of powers of two (as are integer numbers (format I)), whereas unpacked and packed numbers (formats N and P) are represented as a sum of powers of ten.

In unpacked or packed numbers, the position of the decimal point is fixed. In floating-point numbers, however, the position of the decimal point (as the name indicates) is "floating", that is, its position is not fixed, but depends on the actual value.

Floating-point numbers are essential for the computing of trigonometric functions or mathematical functions such as sinus or logarithm.

Precision of Floating-Point Numbers

Due to the nature of floating-point numbers, their precision is limited:

Values which have more significant digits cannot be represented exactly as a floating-point number. No matter how many additional digits there are before or after the decimal point, a floating-point number can cover only the leading 7 or 16 digits respectively.

An integer value can only be represented exactly in a variable of format/length F4 if its absolute value does not exceed 2 24 -1.

Conversion to Floating-Point Representation

When an alphanumeric, unpacked numeric or packed numeric value is converted to floating-point format (for example, in an assignment operation), the representation has to be changed, that is, a sum of powers of ten has to be converted to a sum of powers of two.

Consequently, only numbers that are representable as a finite sum of powers of two can be represented exactly; all other numbers can only be represented approximately.

Examples:

This number has an exact floating-point representation:

 1.25 = 20 + 2-2

This number is a periodic floating-point number without an exact representation:

 1.2 = 20 + 2-3 + 2-4 + 2-7 + 2-8 + 2-11 + 2-12 + ...

Thus, the conversion of alphanumeric, unpacked numeric or packed numeric values to floating-point values, and vice versa, can introduce small errors.

Note:
If an integer, unpacked or packed result of an arithmetic operation (see Result Format and Length in Arithmetic Operations) has to be converted to floating point representation, you should consider to perform the arithmetic operation already in floating point format to improve the precision.

Example:

#F1 (F8) := 1     / 12  /* Result is +8.333330000000000E-02 
#F2 (F8) := 1.0E0 / 12  /* Result is +8.333333333333333E-02

Platform Dependency

Because of different hardware architecture, the representation of floating-point numbers varies according to platforms. This explains why the same application, when run on different platforms, may return slightly different results when floating-point arithmetic are involved. The respective representation also determines the range of possible values for floating-point variables, which is (approximately) ±5.4 * 10-79 to ±7.2 * 1075 for F4 and F8 variables.

Note:
The representation used by your pocket calculator may also be different from the one used by your computer - which explains why results for the same computation may differ.

Top of page

Arithmetic Operations with Date and Time

With formats D (date) and T (time), only addition, subtraction, multiplication and division are allowed. Multiplication and division are allowed on intermediate results of additions and subtractions only.

Date/time values can be added to/subtracted from one another; or integer values (no decimal digits) can be added to/subtracted from date/time values. Such integer values can be contained in fields of formats N, P, I, D, or T.

The intermediate results of such an addition or subtraction may be used as a multiplicand or dividend in a subsequent operation.

An integer value added to/subtracted from a date value is assumed to be in days. An integer value added to/subtracted from a time value is assumed to be in tenths of seconds.

For arithmetic operations with date and time, certain restrictions apply, which are due to the Natural's internal handling of arithmetic operations with date and time, as explained below.

Internally, Natural handles an arithmetic operation with date/time variables as follows:

COMPUTE result-field = operand1 +/- operand2

The above statement is resolved as:

  1. intermediate-result = operand1 +/- operand2

  2. result-field = intermediate-result

That is, in a first step Natural computes the result of the addition/subtraction, and in a second step assigns this result to the result field.

More complex arithmetic operations are resolved following the same pattern:

COMPUTE result-field = operand1 +/- operand2 +/- operand3 +/- operand4

The above statement is resolved as:

  1. intermediate-result1 = operand1 +/- operand2

  2. intermediate-result2 = intermediate-result1 +/- operand3

  3. intermediate-result3 = intermediate-result2 +/- operand4

  4. result-field = intermediate-result3

The resolution of multiplication and division operations is similar to the resolution for addition and subtraction.

The internal format of such an intermediate result depends on the formats of the operands, as shown in the tables below.

Addition

The following table shows the format of the intermediate result of an addition (intermediate-result = operand1 + operand2):

Format of operand1 Format of operand2 Format of intermediate-result
D D Di
D T T
D Di, Ti, N, P, I D
T D, T, Di, Ti, N, P, I T
Di, Ti, N, P, I D D
Di, Ti, N, P, I T T
Di, N, P, I Di Di
Ti, N, P, I Ti Ti
Di Ti, N, P, I Di
Ti Di, N, P, I Ti

Subtraction

The following table shows the format of the intermediate result of a subtraction (intermediate-result = operand1 - operand2):

Format of operand1 Format of operand2 Format of intermediate-result
D D Di
D T Ti
D Di, Ti, N, P, I D
T D, T Ti
T Di, Ti, N, P, I T
Di, N, P, I D Di
Di, N, P, I T Ti
Di Di, Ti, N, P, I Di
Ti D, T, Di, Ti, N, P, I Ti
N, P, I Di, Ti P12

Multiplication or Division

The following table shows the format of the intermediate result of a multiplication (intermediate-result = operand1 * operand2) or division (intermediate-result = operand1 / operand2):

Format of operand1 Format of operand2 Format of intermediate-result
D D, Di, Ti, N, P, I Di
D T Ti
T D, T, Di, Ti, N, P, I Ti
Di T Ti
Di D, Di, Ti, N, P, I Di
Ti D Di
Ti Di, T, Ti, N, P, I Ti
N, P, I D, Di Di
N, P, I T, Ti Ti

Internal Assignments

Di is a value in internal date format; Ti is a value in internal time format; such values can be used in further arithmetic date/time operations, but they cannot be assigned to a result field of format D (see the assignment table below).

In complex arithmetic operations in which an intermediate result of internal format Di or Ti is used as operand in a further addition/subtraction/multiplication/division, its format is assumed to be D or T respectively.

The following table shows which intermediate results can internally be assigned to which result fields (result-field = intermediate-result).

Format of result-field Format of intermediate-result Assignment possible
D D, T yes
D Di, Ti, N, P, I no
T D, T, Di, Ti, N, P, I yes
N, P, I D, T, Di, Ti, N, P, I yes

A result field of format D or T must not contain a negative value.

Examples 1 and 2 (invalid):

COMPUTE DATE1 (D) = DATE2 (D) + DATE3 (D)
COMPUTE DATE1 (D) = DATE2 (D) - DATE3 (D)

These operations are not possible, because the intermediate result of the addition/subtraction would be format Di, and a value of format Di cannot be assigned to a result field of format D.

Examples 3 and 4 (invalid):

COMPUTE DATE1 (D) = TIME2 (T) - TIME3 (T)
COMPUTE DATE1 (D) = DATE2 (D) - TIME3 (T)

These operations are not possible, because the intermediate result of the addition/subtraction would be format Ti, and a value of format Ti cannot be assigned to a result field of format D.

Example 5 (valid):

COMPUTE DATE1 (D) = DATE2 (D) - DATE3 (D) + TIME3 (T)

This operation is possible. First, DATE3 is subtracted from DATE2, giving an intermediate result of format Di; then, this intermediate result is added to TIME3, giving an intermediate result of format T; finally, this second intermediate result is assigned to the result field DATE1.

Examples 6 and 7 (invalid):

COMPUTE DATE1 (D) = DATE2 (D) + DATE3 (D) * 2
COMPUTE TIME1 (T) = TIME2 (T) - TIME3 (T) / 3

These operations are not possible, because the attempted multiplication/division is performed with date/time fields and not with intermediate results.

Example 8 (valid):

COMPUTE DATE1 (D) = DATE2 (D) + (DATE3(D) - DATE4 (D)) * 2

This operation is possible. First, DATE4 is subtracted from DATE3 giving an intermediate result of format Di; then, this intermediate result is multiplied by two giving an intermediate result of format Di; this intermediate result is added to DATE2 giving an intermediate result of format D; finally, this third intermediate result is assigned to the result field DATE1.

If a format T value is assigned to a format D field, you must ensure that the time value contains a valid date component.

Top of page

Performance Considerations for Mixed Format Expressions

When doing arithmetic operations, the choice of field formats has considerable impact on performance:

For business arithmetic, only fields of format P (packed numeric) should be used. The number of decimal digits in all operands should agree where possible.

For scientific arithmetic, fields of format F (floating point) should be used, if possible.

In expressions where formats are mixed between numeric (N, P) and floating point (F), a conversion to floating point format is performed. This conversion results in considerable CPU load. Therefore it is recommended to avoid mixed format expressions in arithmetic operations.

Top of page

Precision of Results of Arithmetic Operations

Operation Digits Before Decimal Point Digits After Decimal Point
Addition/Subtraction Fi + 1 or Si + 1 (whichever is greater) Fd or Sd (whichever is greater)
Multiplication Fi + Si
  • if Fd + Sd is less than MAXPREC: Fd + Sd

  • if Fd + Sd is greater than or equal to MAXPREC:

    Fd or Sd or MAXPREC (whichever is greater)

Division Fi + Sd (see below)
Exponentiation 29 - Fd (See Exception below) Fd
Square Root
  • if Fi is even: Fi/2

  • if Fi is odd: (Fi + 1)/2

  • if Fi is even: 31 – Fi/2 or MAXPREC (whichever is less)

  • if Fi is odd: 31 – (Fi + 1)/2 or MAXPREC (whichever is less)

- where:

F First operand
S Second operand
R Result
i Digits before decimal point
d Digits after decimal point
MAXPREC Maximum number of digits after the decimal point as determined by means of the MAXPREC option of the COMPOPT system command or by the MAXPREC keyword parameter of the CMPO profile parameter; the default value is 7

- where:

F First operand
S Second operand
R Result
i Digits before decimal point
d Digits after decimal point

Exception:

If the exponent has one or more digits after the decimal point, the exponentiation is internally carried out in floating point format and the result will also have floating point format. See Arithmetic Operations with Floating-Point Numbers for further information.

Digits after Decimal Point for Division Results

The precision of the result of a division depends whether a result field is available or not:

* If the ROUNDED option is used, the precision of the result is internally increased by one digit before the result is actually rounded, as long as the value of the MAXPREC option is not exceeded.

A result field is available (or assumed to be available) in a COMPUTE and DIVIDE statement, and in a logical condition in which the division is placed after the comparison operator (for example: IF #A = #B / #C THEN ...).

A result field is assumed to be not available in a logical condition in which the division is placed before the comparison operator (for example: IF #B / #C = #A THEN ...).

Exception:

If both dividend and divisor are of integer format and at least one of them is a variable, the division result is always of integer format (regardless of the precision of the result field and of whether the ROUNDED option is used or not).

Precision of Results for Arithmetic Expressions

The precision of arithmetic expressions, for example: #A / (#B * #C) + #D * (#E - #F + #G), is derived by evaluating the results of the arithmetic operations in their processing order. For further information on arithmetic expressions, see arithmetic-expression in the COMPUTE statement description.

Top of page

Error Conditions in Arithmetic Operations

In an addition, subtraction, multiplication or division, an error occurs if the total number of digits (before and after the decimal point) of the result is greater than 31.

In an exponentiation, an error occurs in any of the following situations:

Top of page

Processing of Arrays

Generally, the following rules apply:

The following topics are covered below:

Definitions of Array Dimensions

The first, second and third dimensions of an array are defined as follows:

Number of Dimensions Properties
3 #a3(3rd dim., 2nd dim., 1st dim.)
2 #a2(2nd dim., 1st dim.)
1 #a1(1st dim.)

Assignment Operations with Arrays

If an array range is assigned to another array range, the assignment is performed element by element.

Example:

DEFINE DATA LOCAL
1 #ARRAY(I4/1:5) INIT <10,20,30,40,50>
END-DEFINE
*
MOVE #ARRAY(2:4) TO #ARRAY(3:5)
/* is identical to
/* MOVE #ARRAY(2) TO #ARRAY(3)
/* MOVE #ARRAY(3) TO #ARRAY(4)
/* MOVE #ARRAY(4) TO #ARRAY(5)
/*  
/* #ARRAY contains  10,20,20,20,20

If a single occurrence is assigned to an array range, each element of the range is filled with the value of the single occurrence. (For a mathematical function, each element of the range is filled with the result of the function.)

Before an assignment operation is executed, the individual dimensions of the arrays involved are compared with one another to check if they meet one of the conditions listed below. The dimensions are compared independently of one another; that is, the 1st dimension of the one array is compared with the 1st dimension of the other array, the 2nd dimension of the one array is compared with the 2nd dimension of the other array, and the 3rd dimension of the one array is compared with the 3rd dimension of the other array.

The assignment of values from one array to another is only allowed under one of the following conditions:

Example - Array Assignments:

The following program shows which array assignment operations are possible.

 DEFINE DATA LOCAL
 1 A1   (N1/1:8)
 1 B1   (N1/1:8)
 1 A2   (N1/1:8,1:8)
 1 B2   (N1/1:8,1:8)
 1 A3   (N1/1:8,1:8,1:8)
 1 I    (I2)          INIT <4>
 1 J    (I2)          INIT <8>
 1 K    (I2)          CONST <8>
 END-DEFINE
 *
 COMPUTE A1(1:3) = B1(6:8)                                      /* allowed
 COMPUTE A1(1:I) = B1(1:I)                                      /* allowed
 COMPUTE A1(*)   = B1(1:8)                                      /* allowed
 COMPUTE A1(2:3) = B1(I:I+1)                                    /* allowed
 COMPUTE A1(1)   = B1(I)                                        /* allowed
 COMPUTE A1(1:I) = B1(3)                                        /* allowed
 COMPUTE A1(I:J) = B1(I+2)                                      /* allowed
 COMPUTE A1(1:I) = B1(5:J)                                      /* allowed
 COMPUTE A1(1:I) = B1(2)                                        /* allowed
 COMPUTE A1(1:2) = B1(1:J)                                      /* NOT ALLOWED (NAT0631)
 COMPUTE A1(*)   = B1(1:J)                                      /* NOT ALLOWED (NAT0631)
 COMPUTE A1(*)   = B1(1:K)                                      /* allowed
 COMPUTE A1(1:J) = B1(1:K)                                      /* NOT ALLOWED (NAT0631)
 *
 COMPUTE A1(*)       = B2(1,*)                                  /* allowed
 COMPUTE A1(1:3)     = B2(1,I:I+2)                              /* allowed
 COMPUTE A1(1:3)     = B2(1:3,1)                                /* NOT ALLOWED (NAT0631)
 *
 COMPUTE A2(1,1:3)   = B1(6:8)                                  /* allowed
 COMPUTE A2(*,1:I)   = B1(5:J)                                  /* allowed
 COMPUTE A2(*,1)     = B1(*)                                    /* NOT ALLOWED (NAT0631)
 COMPUTE A2(1:I,1)   = B1(1:J)                                  /* NOT ALLOWED (NAT0631)
 COMPUTE A2(1:I,1:J) = B1(1:J)                                  /* allowed
 *
 COMPUTE A2(1,I)     = B2(1,1)                                  /* allowed
 COMPUTE A2(1:I,1)   = B2(1:I,2)                                /* allowed
 COMPUTE A2(1:2,1:8) = B2(I:I+1,*)                              /* allowed
 *
 COMPUTE A3(1,1,1:I)   = B1(1)                                  /* allowed
 COMPUTE A3(1,1,1:J)   = B1(*)                                  /* NOT ALLOWED (NAT0631)
  COMPUTE A3(1,1,1:I)   = B1(1:I)                               /* allowed
 COMPUTE A3(1,1:2,1:I) = B2(1,1:I)                              /* allowed
 COMPUTE A3(1,1,1:I)   = B2(1:2,1:I)                            /* NOT ALLOWED (NAT0631)
 END

Comparison Operations with Arrays

Generally, the following applies: if arrays with multiple dimensions are compared, the individual dimensions are handled independently of one another; that is, the 1st dimension of the one array is compared with the 1st dimension of the other array, the 2nd dimension of the one array is compared with the 2nd dimension of the other array, and the 3rd dimension of the one array is compared with the 3rd dimension of the other array.

The comparison of two array dimensions is only allowed under one of the following conditions:

Example - Array Comparisons:

The following program shows which array comparison operations are possible:

 DEFINE DATA LOCAL
 1 A3  (N1/1:8,1:8,1:8)
 1 A2  (N1/1:8,1:8)

 1 A1  (N1/1:8)
 1 I   (I2)   INIT <4>
 1 J   (I2)   INIT <8>
 1 K   (I2)   CONST <8>
 END-DEFINE
 *
 IF A2(1,1)     = A1(1)               THEN IGNORE END-IF /* allowed
 IF A2(1,1)     = A1(I)               THEN IGNORE END-IF /* allowed
 IF A2(1,*)     = A1(1)               THEN IGNORE END-IF /* allowed
 IF A2(1,*)     = A1(I)               THEN IGNORE END-IF /* allowed
 IF A2(1,*)     = A1(*)               THEN IGNORE END-IF /* allowed
 IF A2(1,*)     = A1(I -3:I+4)        THEN IGNORE END-IF /* allowed
 IF A2(1,5:J)   = A1(1:I)             THEN IGNORE END-IF /* allowed
 IF A2(1,*)     = A1(1:I)             THEN IGNORE END-IF /* NOT ALLOWED(NAT0629)
 IF A2(1,*)     = A1(1:K)             THEN IGNORE END-IF /* allowed
 *
 IF A2(1,1)     = A2(1,1)             THEN IGNORE END-IF /* allowed
 IF A2(1,1)     = A2(1,I)             THEN IGNORE END-IF /* allowed
 IF A2(1,*)     = A2(1,1:8)           THEN IGNORE END-IF /* allowed
 IF A2(1,*)     = A2(I,I -3:I+4)      THEN IGNORE END-IF /* allowed
 IF A2(1,1:I)   = A2(1,I+1:J)         THEN IGNORE END-IF /* allowed
 IF A2(1,1:I)   = A2(1,I:I+1)         THEN IGNORE END-IF /* NOT ALLOWED(NAT0629)
 IF A2(*,1)     = A2(1,*)             THEN IGNORE END-IF /* NOT ALLOWED(NAT0629)
 IF A2(1,1:I)   = A1(2,1:K)           THEN IGNORE END-IF /* NOT ALLOWED(NAT0629)
 *
 IF A3(1,1,*)   = A2(1,*)             THEN IGNORE END-IF /* allowed
 IF A3(1,1,*)   = A2(1,I -3:I+4)      THEN IGNORE END-IF /* allowed
 IF A3(1,*,I:J) = A2(*,1:I+1)         THEN IGNORE END-IF /* allowed
 IF A3(1,*,I:J) = A2(*,I:J)           THEN IGNORE END-IF /* allowed
 END

When you compare two array ranges, note that the following two expressions lead to different results:

#ARRAY1(*) NOT EQUAL #ARRAY2(*) 
NOT #ARRAY1(*) = #ARRAY2(*)

Example:

Arithmetic Operations with Arrays

A general rule about arithmetic operations with arrays is that the number of occurrences of the corresponding dimensions must be equal.

The following illustrates this rule:

#c(2:3,2:4) := #a(3:4,1:3) + #b(3:5)

In other words:

Array Dimension Number Number of Occurrences Range
#c 2nd 2 2:3
#c 1st 3 2:4
#a 2nd 2 3:4
#a 1st 3 1:3
#b 1st 3 3:5

The operation is performed element by element.

Note:
An arithmetic operation of a different number of dimensions is allowed.

For the example above, the following operations are executed:

#c(2,2) := #a(3,1) + #b(3)

#c(2,3) := #a(3,2) + #b(4)

#c(2,4) := #a(3,3) + #b(5)

#c(3,2) := #a(4,1) + #b(3)

#c(3,3) := #a(4,2) + #b(4)

#c(3,4) := #a(4,3) + #b(5)

Below is a list of examples of how array ranges may be used in the following ways in arithmetic operations (in COMPUTE, ADD or MULTIPLY statements). In examples 1-4, the number of occurrences of the corresponding dimensions must be equal.

  1. range + range = range.

    The addition is performed element by element.

  2. range * range = range.

    The multiplication is performed element by element.

  3. scalar + range = range.

    The scalar is added to each element of the range.

  4. range * scalar = range.

    Each element of the range is multiplied by the scalar.

  5. range + scalar = scalar.

    Each element of the range is added to the scalar and the result is assigned to the scalar.

  6. scalar * range = scalar2.

    The scalar is multiplied by each element of the array and the result is assigned to scalar2.

Since no intermediate results will be generated for arithmetic operations as shown in the examples 1-4, the format of the computed result (see Result Format and Length in Arithmetic Operations) must be the same as the format of the result operand (the formats P and N are considered to be the same).

Example:

DEFINE DATA LOCAL
1 #ARRAYI4(I4/1:5)
1 #ARRAYP5(P5/1:5)
END-DEFINE
*
#ARRAYI4(*) := #ARRAYP5(*) + 1  /* NOT ALLOWED(NAT0294)

Since no intermediate results will be generated for arithmetic operations as shown in the above examples, the result of overlapping index ranges is computed element by element.

Example:

DEFINE DATA LOCAL
1 #ARRAY(I4/1:5) INIT <10,20,30,40,50>
END-DEFINE
*
#ARRAY(3:5) := #ARRAY(2:4) + 1
/* is identical to
/* #ARRAY(3) := #ARRAY(2) + 1
/* #ARRAY(4) := #ARRAY(3) + 1
/* #ARRAY(5) := #ARRAY(4) + 1
/*  
/* #ARRAY contains  10,20,21,22,23

Top of page