Natural for Mainframes Version 8.2.5 for Mainframes
 —  Programming Guide  —

Compilation Aspects

Below is an overview of the compilation options and parameters that have an influence on how the completed source code is checked by the compiler and how it is generated into Natural internal object code that can be interpreted and executed by the Natural runtime system.


Compiler Options and Parameters

Compilation options can be specified at the following levels:

  1. Statically

    in the Natural parameter module by specifying the

  2. Dynamically

    by specifying the profile parameters

  3. Within a Natural session

  4. For the current Natural object

    by specifying

Top of page

Other Parameters Influencing the Compiler

The settings of the following profile or session parameters are considered during compilation and may give rise to an error message in case the source code contains different settings:

Parameter Name Short Description Comment
CFICU Unicode and Code Page Support Output of Unicode constants in I/O statements (for example, WRITE U'ABC') is allowed only when CFICU=ON.
CP Default Code Page Name Specifies the code page of the source.
DC Character for Decimal Point Notation Character used for separating integer/precision digits when defining fields of format N or P and constants.
FS Format Specification Allows or disallows the use of variables that were not defined before.
ID Input Delimiter Character For example, to delimit values in an INIT clause.
LS Line Size Specifies the default size for a print line in a report (0 - 31). The setting can be overwritten by specifying an explicit FORMAT statement in the source code.
PS Page Size Maximum number of lines that may be output by a single I/O statement (for example, WRITE). Non-compliance with the basic setting will cause an error. The setting can be overwritten by specifying an explicit FORMAT statement in the source code.
SF Spacing Factor Number of spaces to be inserted between field settings of columns on Natural reports created using a DISPLAY statement. The setting can be overwritten by specifying an explicit FORMAT statement in the source code.
SOSI Shift-Out/Shift-In Codes for Double-Byte Character Set Specifies the shift characters to identify a double-byte character set (DBCS) string.
ZP Zero Printing Output of blanks or zeros for a numerical constant which contains a value of all zeros. The setting can be overwritten by specifying an explicit FORMAT statement in the source code.

Top of page