This section provides an overview of the parameters used during loading of SMA tables and copy steps.
During the loading of SMA tables from a tape (Tabload), the library group definition is taken from the global variable MVS-LIB-GROUP and is stored into the field Library Grp for each data set on the tape (see Copy Parameters screen below).
08:31:54 *** SYSTEM MAINTENANCE AID *** 2005-10-10
User: SAG - Copy Parameters - TPCDSM11
Volser ..... T78063
Name on tape NAT414.JOBS
Description ......... MVS Example jobs for installation
Symbolic Dataset Name NAT414.JOBS
Dataset Organization PO
Size (Kilo byte) .... 1204
Dataset created on .. 2005-10-07 08:01:50
Dataset copied on....
Library Grp SAGLIB______________
Name on Disk ________________________________________________________________
Disk ....... ______
Device Type ________
Command ===>
Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
Help Menu Exit Canc
|
To change the library group after loading the SMA tables from a
tape, go to each data set (T(ape) > DA(taset) >
MO(dify)) and change the Library Grp field.
Note:
A change of the global variable MVS-LIB-GROUP after loading from
a tape will have no effect on the data set entries or copy steps.
Enter the tape menu and the line command
MA for a specific tape.
09:07:18 *** SYSTEM MAINTENANCE AID *** 2005-10-10
User: SAG - Datasets On Tape - TPPDSM11
Page: 3 sorted by Volser: T78063 Rec: 0062
---->
Code Dataset Name Description On Disk As C
*_______________ *_____________________________ *___________________ *
__ * COPY IN GROUP: PROD3LIB PROD3LIB.BTE421.LD01
__ BTE421.LS01 MVS S01.LOAD CORRECTION
__ * COPY IN GROUP: PROD3LIB PROD3LIB.BTE421.LS01
__ NAT414.ERRN ERROR MESSAGES FILE
__ NAT414.EXPL EXAMPLE INPL FILE
__ NAT414.INPL INPL DATASET SAGLIB.NAT414.INPL
__ NAT414.IS01 S01.INPL CORRECTION
MA NAT414.JOBS MVS EXAMPLE JOBS FOR INSTALLAT SAGLIB.NAT414.JOBS
__ NAT414.LOAD MVS LOAD DATASET SAGLIB.NAT414.LOAD
__ NAT414.SRCE MVS SOURCE DATASET SAGLIB.NAT414.SRCE
__ NAT414.SYSF SYSTEM FILE SAGLIB.NAT414.SYSF
__ NCF414.LOAD MVS LOAD DATASET SAGLIB.NCF414.LOAD
__ NCF414.SRCE MVS SOURCE DATASET SAGLIB.NCF414.SRCE
__ SMA131.ERRN ERROR MESSAGES FILE
Command ===>
Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
Help Menu Exit Sort Prnt -- - + ++ > Canc
|
If you mark (MA) a data set for copy, the
data set fields Disk and Device Type (see below) will be filled from the global
parameters MVS-LIB-GROUP-VOL and
MVS-LIB-GROUP-UNIT. The field Library Grp has already
been stored at load time (Tabload). A mark for copy will also be performed
automatically by SMA, if a JCL generation from a user environment is performed.
All data sets that are needed more than once during installation or operation
of the product, (i.e. LOAD or SRCE data sets) will be marked for copy by SMA,
before the job generation starts. Other data sets that are needed only once
(i.e. INPL or ERRN data sets) will always be loaded directly from tape, unless
the user marked them for copy manually (T > DA >
MA).
Enter the line command MO for a specific
data set on tape.
08:31:54 *** SYSTEM MAINTENANCE AID *** 2005-10-10
User: SAG - Copy Parameters - TPCDSM11
Volser ..... T78063
Name on tape NAT414.JOBS
Description ......... MVS Example jobs for installation
Symbolic Dataset Name NAT414.JOBS
Dataset Organization PO
Size (Kilo byte) .... 1204
Dataset created on .. 2005-10-07 08:01:50
Dataset copied on.... 2005-10-10 08:38:54
Library Grp SAGLIB______________
Name on Disk SAGLIB.NAT414.JOBS_____________________________________________
Disk ....... SAGVOL
Device Type 3390___
Command ===>
Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
Help Menu Exit Canc
|
Enter the tape menu and the line command JC (Generate
JCL).
09:10:29 *** SYSTEM MAINTENANCE AID *** 2005-10-10
User: SAG - Archived Tapes - TPVOLM11
Page: 1 sorted by Rec: 0001
---->
Code Volser Description Add Date
*______ *_______________________________________ *__________
JC T78063 SMA211 2005-10-07
Command ===>
Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
Help Menu Exit Sort Prnt -- - + ++ Prod Canc
|
The copy job will be generated.
10:09:03 *** SYSTEM MAINTENANCE AID *** 2005-10-10
User: SAG - Generated Tape Jobs - TPJOBM11
Reposition to Job: ________ Tape: T78063
Cmd Job Description Status
__ T063 COPY DATASETS FROM TAPE Open
Command ===>
Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
Help Menu Exit -- ++ - + Print Canc
|
The involved skeletons for copy data sets all start with COPY-* (i.e. COPY-PO, COPY-POE, COPY-PS...). Depending on the Dataset Organization in the data set parameters the corresponding skeleton will be selected. (i.e. if the Dataset Organization parameter is PO, then the skeleton COPY-PO is selected). The Library Group, Unit and Volume will be taken from the corresponding fields on the Copy-Parameters screen for the data set. Other values such as Expiration Date and Tape Unit will be taken from the default environment (OS/MVS).
Enter the environment menu and the line command JC
(Generate JCL).
07:31:52 *** SYSTEM MAINTENANCE AID *** 2005-09-27
User: SAG - Environment Maintenance - ENMENM11
Page: 1 Rec: 0007
Code Environment Description
*_______ *_________________________________________________
__ OS/MVS DEFAULT-ENVIRONMENT FOR OS/MVS
JC PROD1 PRODUCTION 1
__ PROD2 PRODUCTION 2
__ SMA SMA INSTALLATION
__ TDEV DEVELOPMENT
__ TEST1 TEST INSTALLATION 1
__ TEST2 TEST INSTALLATION 2
Command ===>
Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
Help Menu Exit Sort Prnt -- - + ++ Canc
|
The copy job will be generated.
07:51:23 *** SYSTEM MAINTENANCE AID *** 2005-09-28
User: SAG - Generated Environment Jobs - ENJOBM11
Page: 1 Environment: PROD1 Rec: 0021
Code Job Description Status
*_________ *_______________________________ *__________
__ Report Installation Guide Open
__ T955 COPY DATASETS FROM TAPE Open
__ P060 READ ME; DO NOT SUBMIT Open
__ I005 CREATE TABLES FOR TP MONITOR Open
__ I008 ALLOCATE DATASETS Open
__ I009 COPY DATASETS Open
__ I010 INSTALL PERMANENT ADASVC Open
__ I011 INSTALL TEMPORARY ADASVC Open
__ I030 DEFINE AND FORMAT DATABASE Open
__ I040 ADABAS NUCLEUS Open
__ I050 CREATE ADABAS FILES Open
__ I055 ASSEMBLIES OF BATCH NATURAL Open
__ I056 AUXILIARY ASSEMBLIES Open
__ I060 PARM + LINK BATCH NATURAL Open
Command ===>
Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
Help Menu Exit Prnt -- - + ++ Refr Canc
|
The involved skeletons for copying data sets all start with COPY-
(i.e. COPY-PO, COPY-POE, COPY-PS...). If the LIBGROUP
parameter in the user environment differs from the Library Grp field in the
data set entry:
the generated job will first copy the data set from the tape to the original Library Group (Library Grp field) if the data set has not been copied yet to that location and is set to mark for copy (manually or automatically by SMA)
afterwards a copy step will copy the data set from that original location to a data set with the LIBGROUP setting of the user environment.
Other values such as Expiration Date and Tape Unit will be taken from the values of the user environment.