This document covers the following topics:
Depending on your selection in the product selection tree, some or all of the following entries have been created in the Windows
menu:Under All Programs > Software AG > Tools:
Predict n.n
All Programs > Software AG > Documentation
where n.n stands for the current version number. The Start menu group name (by default, this is "Software AG") can be changed during the installation.
After you have installed your product, you need to set up a number of files, parameters and individual settings depending on your environment. These are described below. To set them up, you use the SYSPCI utility. For detailed information on this utility, see SYSPCI Utility - Product Configuration and Initialization in Natural's Tools and Utilities documentation.
Predict requires the following Adabas system file:
FDIC
, where the logical file number (LFILE
)
is 253.
The database ID and file number of the new or existing file that you
specify using the SYSPCI utility are entered into the parameter files
PRDPARM
and NATPARM
. If applicable, database ID and
file number will be entered into further parameter files like
NDVPARM
, NSCPARM
and NBSPARM
.
For the Predict Coordinator functions Load or Import the following Adabas system file is required:
COORDINATOR_FDIC
, where DBID
and
FNR
will be stored on the FDIC
by the SYSPCI
utility.
The required Adabas files can either be local or remote.
Remote Access
If the file is located in a remote database, Entire Net-Work must
be active and the database must be accessible.
Existing Local File
Before you start the SYSPCI utility, make sure that the Adabas
database containing the required files is active. With this version, you can
continue to use your existing files. No migration
of data from the previous version to the current version is
necessary.
New File
Before you start the SYSPCI utility, make sure that the Adabas
database which will contain the required files is active. The SYSPCI utility
will load and initialize these files. This should be also done if another file
is required for your product.
Before you create new files with the SYSPCI utility, make sure that the ASSO and DATA sizes of your Adabas database are appropriate for these files. It is therefore recommended that you check the Adabas .fdu files in the <install-dir>/<product>/INSTALL/<product-code> directory for the used sizes. If required, change your database setup so that the files can be created.
For Predict, the SYSPCI utility offers the following optional functions:
Option | Description |
---|---|
Convert FDIC data | If marked the Data on the Predict System File are converted to 8.4 Format, see Convert the Data on the Predict System File to 8.4 Format in Optional Steps below. |
Load FDIC description | If marked, the Predict Description of the Predict System File is loaded. |
Load example data | If marked, the Predict example data is loaded. |
In order to invoke the SYSPCI utility, you must first invoke Natural. You can then invoke the SYSPCI utility using the command line.
To invoke the SYSPCI utility
From the Windows
menu, choose to invoke Natural.From the
menu, choose to switch on the display of the command line.Enter the following command in the command line:
SYSPCI
For more information, see SYSPCI Utility - Product Configuration and Initialization in Natural's Tools and Utilities documentation.
SYSPCI may perform the optional steps Initialize product, Assign Coord. FDIC, Load FDIC description or Load example data.
If the optional installation steps are not performed by SYSPCI or if Natural Security (NSC) is installed, perform the following steps:
Perform the steps in the given order unless mentioned otherwise. Please observe the notes where available.
Note:
This step is not required for first-time installations.
This step must be performed manually by starting Natural with
PARM=PRDPARM
.
This step converts Predict Version 4.6, Version 8.2 or Version 8.3 data to Version 8.4 format. If the data on your Predict system file already is in Version 8.4 format, a corresponding message is returned.
Note:
We recommend you save your Predict system file in Version 4.6,
Version 8.2 or 8.3 format before proceeding with the steps below.
To set up your environment so you can use the Coordinator, start a Predict 8.4 online session (using the newly installed FDIC file) and perform the following:
Log on to the library SYSDICCO
Call the Function Main Menu by entering MENU at the NEXT prompt
Call the function C > Version 4.6 (or Version 8.2 or Version 8.3) data
When you execute this step in batch mode, the CMSYNIN file should contain the following:
LOGON SYSDICCO MENU CONVERT VERSION84 FIN |
Now the data is in Version 8.4 format.
This step is optional.
Start a Predict 8.4 online session or perform the following batch mode commands:
LOGON SYSDIC MENU NEWGEN1 FIN
Note:
This step is not required for upgrade installations. This step
can also be performed by SYSPCI if the options Initialize
product or Assign Coord. FDIC have been
selected.
This step must be performed manually by starting Natural with
PARM=PRDPARM
.
To set up your environment so you can use the Coordinator, start a Predict 8.4 online session (using the newly installed FDIC file) and perform the following:
Log on to the library SYSDIC
Call the Function Main Menu by entering MENU at the NEXT prompt
Call the function Defaults > Coordinator Defaults
Specify the parameters Coordinator FDIC DBID/FNR with the file number and database ID of the Coordinator FDIC.
This step must be performed manually by starting Natural with
PARM=PRDPARM
.
If Natural Security is installed, define the following libraries to Natural Security:
SYSDIC, SYSDICBE, SYSDICCO, SYSDICH and SYSDICMA.
Note:
This step can also be performed by SYSPCI if the option
Load FDIC description has been selected.
This step is optional.
To load the Predict description of the Predict system file, enter:
setenv WRKF1 <install-dir>/Predict/INSTALL/data/ALLDATA.DAT
Start Natural with PARM=PRDPARM
.
When you execute this step in batch mode, the CMSYNIN file should contain the following:
LOGON SYSDICBE MENU LOAD OBJECTTYPE ALL,REPLACE=Y,ADA=N FIN |
If a previous import operation with the Coordinator terminated abnormally for any reason, the Coordinator FDIC is locked and a corresponding message is returned. Enter the following commands to clear the Coordinator FDIC in batch mode:
LOGON SYSDIC MENU SPECIAL REFRESH FIN |
Note:
This step can also be performed by SYSPCI if the option
Load example data has been selected.
This step is optional.
To load the Predict example data, enter:
setenv WRKF1 <install-dir>/Predict/INSTALL/data/ALLDEMO.DAT
Start Natural with PARM=PRDPARM
.
When you execute this step in batch mode, the CMSYNIN file should contain the following:
LOGON SYSDICBE MENU LOAD OBJECTTYPE ALL,REPLACE=Y,ADA=N FIN |
If a previous import operation with the Coordinator terminated abnormally for any reason, the Coordinator FDIC is locked and a corresponding message is returned. Enter the following commands to clear the Coordinator FDIC in batch mode:
LOGON SYSDIC MENU SPECIAL REFRESH FIN |
This step is optional.
Start a Predict 8.4 online session or perform the following batch mode commands:
LOGON SYSDIC MENU NEWEXGEN FIN
Note:
If you execute this function in batch, please ensure that you
have set Batch execution to N (No) on the Natural Security Modify Library
screen of library SYSEXT.
Warning: For users of Predict Version 4.5 or below: If you are using Predict Version 4.5 or below and want to migrate to a newer version, it is necessary to perform the following actions in the order given below. |
Perform a Predict Unload operation using Predict Version 4.5 or below.
The following data need to be unloaded:
If user-defined object-types (UDEs) exist, then their
metadata must be unloaded using UNLOAD METADATA
<UDE-name>
<parameters>
. Specify the unload
parameters that meet your requirements.
All documented objects using UNLOAD OBJECTTYPE ALL
CODE=Y,INTERNAL-ID=Y <parameters>
.
Specify the unload parameters that meet your requirements.
If XRef data are to be transfered to the new FDIC, then they
must be unloaded using UNLOAD OBJECTTYPE XR
<parameters>
. Specify the unload
parameters that meet your requirements.
If user-defined Retrieval Models exist, then these must be
unloaded using UNLOAD RETRIEVALMODEL <object
type> <parameters>
.
Specify the unload parameters that meet your requirements.
Install Predict Version 8.4.
Perform a Predict Load operation using Predict Version 8.4.