System Variables
System variables affect the behavior of Entire Connection during
runtime.
See also: *PASSWORD1
-
4
and
*USERID1
-
4
.
System variables can be modified during runtime, using the
SET
command. Using the TOGGLE
command, you can also modify system variables of type Binary.
This document covers the following topics:
Types of System Variables
There are two types of system variables:
-
System variables that affect the whole Entire Connection system
These variables are set at startup time with values from the share
file. You can modify the values during runtime, either from the command line or
from a procedure file. The modifications are valid only as long as
Entire Connection is active. In the corresponding object properties, variable
values can be changed permanently.
-
System variables that only affect specific sessions
When a session is opened, these variables are filled with values
from the session properties. You can modify the values while the session is
open, using a procedure file. The modifications are valid only as long as the
session is open. In the session properties, variable values can be changed
permanently.
Value Types for System Variables
Value Type |
Value |
Binary |
TRUE/FALSE
You can also use the combinations YES/NO and ON/OFF which are
synonymous with TRUE/FALSE. When you display the value of a variable, TRUE or
FALSE is always shown.
|
Date |
Date format (month, day, year and delimiter character) as
defined in the user properties.
|
Path |
{[[drive:]\directory\...\]
filename[.extension]}
|
Integer |
Whole positive number. |
String |
Any ASCII character or a group of ASCII characters. The
maximum length is 254 characters.
|
Parity |
EVEN, MARK, NONE, ODD, SPACE |
Task Name |
Name of a valid task. |
Time |
Time format (hour, minute, second and delimiter character) as
defined in the user properties.
If the delimiter character is A, the time is displayed in the
AM/PM format (for example, 01:30 PM).
|
List of System Variables
The default value of a system variable is indicated by
underlining.
AUDIT
Affects |
System |
Value Type |
Binary |
Valid Values |
OFF/ON
|
Object / Page / Option |
User properties /
Procedure
/ Audit procedure files
|
AUDITXFER
Affects |
System |
Value Type |
Binary |
Valid Values |
OFF/ON
|
Object / Page / Option |
User properties /
Procedure
/ Audit file transfer
|
AUTOLOCK
Affects |
System |
Value Type |
Integer |
Valid Values |
0 - 1440
(minutes)
|
Object / Page / Option |
User properties /
Parameters
1 / Autolock time
|
BAUDRATE
Affects |
Session |
Value Type |
Integer |
Valid Values |
300/1200/2400/4800/9600/14400/19200/28800/38400/57600/115200
|
Object / Page / Option |
Session properties /
Serial
communication / Baud rate
|
BEEP
Affects |
System |
Value Type |
Binary |
Valid Values |
OFF/ON |
Object / Page / Option |
User properties /
Parameters
1 / PC speaker beep on errors and warnings
|
BREAKMS
Affects |
Session |
Value Type |
Integer |
Valid Values |
0 - 1000
500
|
Object / Page / Option |
Session properties /
Serial
communication / Break signal time
|
COMMPORT
Affects |
Session |
Value Type |
Integer |
Valid Values |
1 - 4
2
|
Object / Page / Option |
Session properties /
Serial
communication / COM port
|
CURSOR
Affects |
System |
Value Type |
Integer |
Valid Values |
0 - 4
1 (small)
|
Object / Page / Option |
User properties /
Parameters
1 / Cursor size
|
DATABITS
Affects |
Session |
Value Type |
Integer |
Valid Values |
7 and 8 |
Object / Page / Option |
Session properties /
Serial
communication / Data bits
|
DATE
Affects |
System |
Value Type |
Date |
Valid Values |
All data formats available in the user properties
YMD.
|
Object / Page / Option |
User properties /
Parameters
2 / Date style
|
DISPLAY
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON |
Object / Page / Option |
Session properties /
Procedure
/ Display all host screens while executing a procedure file
|
EAB
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON |
Object / Page / Option |
Session properties /
Display
/ Ignore extended attribute colors
|
ECHO
Affects |
System |
Value Type |
Integer |
Valid Values |
0 - 100
0 (no echo)
|
Object / Page / Option |
Used to debug
procedure files
|
EOSDELAY
INSTOGGLE
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON
|
Object / Page / Option |
Session properties /
Terminal
/ Enable insert mode toggling
|
LOGOFF
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON
|
Object / Page / Option |
Session properties /
Procedure
/ Enable automatic logoff
|
LOGON
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON
|
Object / Page / Option |
Session properties /
Procedure
/ Enable automatic logon
|
LOOPCNT
Affects |
System |
Value Type |
Integer |
Valid Values |
0 - 32767
256
|
Object / Page / Option |
User properties /
Procedure
/ Limit loops in procedure files
|
NATFILE
Affects |
Session |
Value Type |
Integer |
Valid Values |
1-32, if work file
1-31, if printer file
7
|
Object / Page / Option |
Session properties /
File
transfer / Natural work file
|
NCF
Affects |
System |
Value Type |
Binary |
Valid Values |
OFF/ON |
Object / Page / Option |
User properties /
Parameters
2 / Create format file
|
NTCOFF
Affects |
Session |
Value Type |
Path |
Valid Values |
See description of
value types
|
Object / Page / Option |
Session properties /
Procedure
/ Logoff procedure
|
NTCON
Affects |
Session |
Value Type |
Path |
Valid Values |
See description of
value types
|
Object / Page / Option |
Session properties /
Procedure
/ Logon procedure
|
NUMLOCK
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON
|
Object / Page / Option |
Session properties /
Terminal
/ Allow alphanumeric input in numeric fields
|
OEM
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON
|
Object / Page / Option |
Session properties /
File
transfer / Use DOS character set for upload/download in NCD
format
|
PARITY
Affects |
Session |
Value Type |
Parity |
Valid Values |
EVEN, MARK, NONE, ODD,
SPACE
|
Object / Page / Option |
Session properties /
Serial
communication / Parity
|
PCFILE
Affects |
Session |
Value Type |
Integer |
Valid Values |
1-32, if work file
1-31, if printer file
|
Object / Page / Option |
See the description of the
SET
command
|
PRINTOPTION
Affects |
Session |
Value Type |
String |
Valid Values |
Size=nn Orient={P|L}
Duplex={S|V|H}
|
Object / Page / Option |
See the description below. |
With the PRINTOPTION
variable, you can
change the print settings for download to printer and for printing from a
procedure file. You can change the size of the font, the page orientation and
you can define whether to print on one or both sides of the paper.
Note:
The
font
used for printing is defined in the user properties.
The value is a string which may be composed of three elements:
Element |
Description |
Size=nn
|
Font size. nn is a number from 1
to 99.
|
Orient=option
|
Page orientation. Valid options are P (portrait) and L
(landscape).
|
Duplex=option
|
Paper usage. Valid options are S (simplex), V (vertical) and
H (horizontal).
|
The elements must be separated by one blank. There must be at least
one element in the value string. The elements may be in any order.
Example - use font size 16, landscape, and vertical printing on both
sides of the paper:
SET PRINTOPTION "Size=16 Orient=L Duplex=V"
To use the defaults (font size as selected in the user properties,
portrait and printing on one side of the paper), you have to clear the current
settings as follows:
SET PRINTOPTION ""
REMOTEECHO
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON |
Object / Page / Option |
Session properties /
Serial
communication / Remote echo
|
RESPONSE
Affects |
Session |
Value Type |
Integer |
Valid Values |
1 - 1000 (1 - 1000 seconds)
1001 - 2440 (1 - 1440 minutes)
15 (seconds)
Note: These special internal representations for seconds and
minutes are always used when a procedure file is executed (for example, with
the command SET or WAIT ).
Any values for seconds or minutes that you specify using the Configuration
Manager are automatically transformed to the above special internal
representation.
|
Object / Page / Option |
Session properties /
Procedure
/ Maximum host response time
|
STARTTASK
Affects |
System |
Value Type |
Task Name |
Valid Values |
Valid Entire Connection task name |
Object / Page / Option |
User properties /
Parameters
2 / Startup task
|
STATUS
Affects |
Session |
Value Type |
Binary |
Valid Values |
OFF/ON |
Object / Page / Option |
Session properties /
Procedure
/ Display status lines while executing a procedure file
|
STOPBITS
Affects |
Session |
Value Type |
Integer |
Valid Values |
1 or 2
|
Object / Page / Option |
Session properties /
Serial
communication / Stop bits
|
STOPTASK
Affects |
System |
Value Type |
Task Name |
Valid Values |
Valid Entire Connection task name |
Object / Page / Option |
User properties /
Parameters
2 / Shutdown task
|
TCPADDR
Affects |
Session |
Value Type |
String |
Valid Values |
TCP/IP address (no default)
A TCP/IP address can either be a string which is resolved in the
host's table (up to 128 bytes), or it can be formed as follows:
nnn.nnn.nnn.nnn
where nnn is a number between 000 and
255.
|
Object / Page / Option |
Session properties /
TN3270
communication or
Telnet
VTxxx communication / Host name / IP address
|
TCPPORT
TIME
Affects |
System |
Value Type |
Time |
Valid Values |
All time formats available in the user properties
HMS:
|
Object / Page / Option |
User properties /
Parameters
2 / Time style
|