JOB-SWITCHES

File 81
Op-Sys BS2000
Statement PROCESS
Task Query the user switches for a specified user ID.

When running in single-user mode, switches belonging to your own user ID can be reset, and the job switches of the same task can also be queried, set and reset.


Common Fields for all Operating Systems

Dictionary Field Name F/L Mu DE Remarks
ERROR-CODE N3      
ERROR-TEXT A58      
NODE N5   D  
NODE-NAME A16   D  
SYSTEM-MESSAGE-CODE A10      
SYSTEM-CODE B2      
OPTION A6   D Relevant when FUNCTION=WRITE.
SWITCH-NUMBERS A64   D Relevant when FUNCTION=WRITE.
SWITCH-TYPE A7   D  
SWITCH-VALUES A32   D  
USERID A8   D Relevant when FUNCTION=READ.
FUNCTION A8   D Required.

Relevant Error Codes

Code Text BS2000
530 Access denied by Security Facility X
600 Unknown function X
733 User ID does not exist X
750 Invalid operand within operand list X
755 Invalid or no SWITCH-TYPE specified X
799 Entire System Server internal error X
983 Function not supported by multi-user mode X

Field Descriptions

Field Name Type/Length Operating System
FUNCTION (A8)  

Specifies the function to be performed on the switches. Possible options:

Option Explanation
READ  Read switch status.
WRITE  Set switches given in field SWITCH-NUMBERS according to OPTION field.

For restrictions, see the field SWITCH-TYPE.

Field Name Type/Length Operating System
OPTION (A6)  

Operation when FUNCTION=WRITE:

Operation Explanation
INVERT Invert value of the switches given in the list.
OFF Set switches in the list to OFF.
ON Set switches in the list to ON.
Field Name Type/Length Operating System
SWITCH-NUMBERS (A64)  

Relevant when FUNCTION=WRITE. Gives the list of switches to be handled. Each switch must be specified as a 2-digit number between 00 and 31. There is no delimiter between switch numbers.

Example:

The value 031229 means switches 3, 12 and 29.

Field Name Type/Length Operating System
SWITCH-TYPE (A7)  

Defines whether the switches are USER switches or PROCESS switches. Query and modification of PROCESS switches is only possible when the Entire System Server runs in single-user mode. The same goes for WRITE of USER switches. In multi-user mode, the function is executed by the Entire System Server server task and the switches would be set there for the user ID of the server task.

Field Name Type/Length Operating System
SWITCH-VALUES (A32)  

Returns the status of all switches. Possible values:

Value Explanation
N  Switch is off.
Y  Switch is on.
Field Name Type/Length Operating System
USERID (A8)  

Valid only when FUNCTION=READ and SWITCH-TYPE=USER: user ID for which switches are to be read.