In the architecture of modern e-business applications (SOA), loosely coupled systems are becoming more and more important. Reliable messaging is one important technology for this type of system.
Reliable RPC is the Natural RPC implementation of a reliable messaging system. It combines the Natural RPC technology and persistence, which is implemented by means of units of work (UOWs) that are offered by the EntireX Broker. Reliable RPC is characterized by following features:
The Natural RPC client executes a CALLNAT statement
                        				  without waiting for a reply from the server (the RPC message is sent in
                        				  asynchronous mode). 
                     
An RPC server needs not be active at the time the
                        				  CALLNAT is executed.
                     
The reliable RPC message is stored in the EntireX Broker's persistent store until an RPC server is available.
The Natural RPC server executes the reliable RPC by calling the requested subprogram but does not send a reply to the RPC client.
A Natural RPC client may ask the status of the sent reliable RPC messages.
A Natural RPC client may send a reliable RPC message to an EntireX RPC server.
A Natural RPC server may receive a reliable RPC message from an EntireX RPC client.

The Natural RPC client for a reliable RPC is configured in the same way as for a normal Natural RPC. The same Natural RPC client session can send standard RPC requests and reliable RPC messages.
To enable a Natural RPC client to use reliable RPC, the Natural RPC
                  			 client must use application programming interface
                  			 USR2071N for
                  			 an explicit EntireX Broker logon. This implies that the profile parameter ACIVERS
                  			 must be set to 2 or higher.
               
Reliable RPC is used to send messages to a persistent EntireX Broker service. The messages are described by the PDA of the caller and may only contain output parameters. A parameter is defined as "output" in one of the following ways:
If a Natural interface object is used:
In the Attr field on the
                        				  Interface Object
                              				  Generation screen of the SYSRPC utility, set
                        				  the attribute of the parameter to O (output).
                     
Note:
If your parameter definitions do not contain group
                           				  structures, you must set the attribute COMPAT to IDL
                           				  before generating the interface object; see
                           				  Generating
                              				  Interface Objects - General Considerations in the
                           				  SYSRPC Utility documentation.
                        
If no Natural interface object is used:
Use the
                        				  AD=O
                        				  session parameter in the CALLNAT statement.
                     
Note:
If you want to call an EntireX RPC server and if the
                           				  corresponding IDL file contains group structures, then you must use a Natural
                           				  interface object, and the parameter definition for the Natural interface object
                           				  must correspond to the group structure of the IDL file.
                        
If you generate a Natural interface object from an IDL file, the attribute of the parameter is taken from the IDL file. In this case, the IDL file must only contain inbound (from the server's point of view) parameters.
Reliable RPC is enabled at runtime. The client has to set one of two different modes before issuing a reliable RPC request:
AUTO_COMMIT
CLIENT_COMMIT
While AUTO_COMMIT commits each message implicitly after
                  			 sending it, a series of RPC messages sent in a unit of work (UOW) can be
                  			 committed or rolled back explicitly using CLIENT_COMMIT mode.
               
For this purpose, Natural provides the two application programming
                  			 interfaces USR6304N and USR6305N. With interface
                  			 USR6304N, the mode for reliable RPC is set. With interface
                  			 USR6305N, a unit of work that has been created with
                  			 CLIENT_COMMIT can be committed or rolled back.
               
 To make use of
To make use of USR6304N
Copy the subprogram USR6304N from the library
                        					 SYSEXT to the library SYSTEM or to the steplib
                        					 library or to any application in the client environment.
                     
Using the DEFINE
                              					 DATA statement, specify the following parameters:
                     
| Parameter | I/O | Format | Description | |
|---|---|---|---|---|
| P-FUNC | I | A01 | Function code; possible values are: | |
| P(Put) | Set the mode for reliable RPC. The mode applies to all subsequent calls. | |||
| G(Get) | Get the previously specified mode. | |||
| P-MODE | I/O | N01 | Mode for reliable RPC: | |
| 0 | No reliable RPC (standard RPC execution) | |||
| 1 | Reliable RPC AUTO_COMMIT | |||
| 2 | Reliable RPC CLIENT_COMMIT | |||
| P-RC | O | N04 | Return code | |
| P-MESSAGE | O | A80 | Message text | |
In the calling program on the client side, specify the following statement:
CALLNAT 'USR6304N' P-FUNC P-MODE P-RC P-MESSAGE
Note:
The mode CLIENT_COMMIT cannot be
                     			 changed if reliable RPC messages have been sent but not yet committed or rolled
                     			 back.
                  
 To make use
To make use of USR6305N
Copy the subprogram USR6305N from the library
                        					 SYSEXT to the library SYSTEM or to the steplib
                        					 library or to any application in the client environment.
                     
Using the DEFINE
                              					 DATA statement, specify the following parameters:
                     
| Parameter | I/O | Format | Description | |
|---|---|---|---|---|
| P-FUNC | I | A08 | Function code; possible values are: | |
| COMMIT | Commit the sent reliable RPC messages. The messages are now available for an RPC server. | |||
| ROLLBACK | Discard the already sent reliable RPC messages. | |||
| P-RC | O | N04 | Return code | |
| P-MESSAGE | O | A80 | Message text | |
In the calling program on the client side, specify the following statement:
CALLNAT 'USR6305N' P-FUNC P-MODE P-RC P-MESSAGE
The Natural RPC server for reliable RPC is configured in the same way as for normal Natural RPC. The same Natural RPC server session can process standard RPC requests and reliable RPC messages.
To enable the processing of reliable RPC messages, the
                  			 profile parameter ACIVERS
                  			 must be set to 2 or higher.
               
To view the status of sent reliable RPC messages, Natural provides
                  			 the application programming interface USR6306N. With
                  			 USR6306N you can get the status of all reliable RPC messages that
                  			 you have previously sent under your user ID. USR6306N must not
                  			 necessarily be called within the Natural session in which the reliable RPC
                  			 messages have been sent. If USR6306N is used in a different
                  			 Natural session, the application programming interface
                  			 USR2071N must
                  			 first be used to log on to the EntireX Broker with the same user ID that has
                  			 been used to send the reliable RPC messages.
               
The reliable RPC messages are implemented by EntireX Broker unit of works (UOWs). The information about reliable RPC messages is therefore information about UOWs.
 To make use of
To make use of USR6306N
Copy the subprogram USR6306N from the library
                        					 SYSEXT to the library SYSTEM or to the steplib
                        					 library or to any application in the client environment.
                     
Using the DEFINE
                              					 DATA statement, specify the following parameters:
                     
| Parameter | I/O | Format | Description | 
|---|---|---|---|
| P-UOW-ID-IN | I | A16 | ID for the UOW to be retrieved.
                                 								Possible values are: UOWID of a UOW 
 
 | 
| P-USER-ID | O | A32 | User ID of the user who has created the UOWs. | 
| P-BROKER-ID | O | A32 | Broker ID of the EntireX Broker that hosts the UOWs. | 
| P-UOW-COUNT | O | I4 | Number of UOWs in the P-UOW-INFOarray. | 
| P-UOW-INFO
                                    								(/1:*) | X-array with information about each UOW | ||
| P-UOW-ID | O | A32 | ID of the UOW | 
| P-UOW-STATUS | O | A10 | Status of the UOW according to
                                 								EntireX Broker The status depends on the processing state and is assigned by the EntireX Broker. | 
| P-USERR-STATUS | O | A32 | User information about the UOW. This is typically error information that has been set by the RPC server. | 
| P-CREATE-TIME | O | A32 | Creation time of the UOW according to EntireX Broker. | 
| P-RC | O | N04 | Return code | 
| P-MESSAGE | O | A80 | Message text | 
In the calling program on the client side, specify the following statement: