With this session parameter, you can specify leading characters that
                          are displayed immediately before a field output by a
                          DISPLAY statement.
                          The width of the output column is enlarged accordingly.
               
| Possible settings | any character | Up to 10 characters may be
                                           specified. Notes: 
 | |
|---|---|---|---|
| Default setting | none | ||
| Specification within session | yes | ||
| Applicable statements | FORMAT | Parameter may be specified
                                           dynamically with the FORMATstatement. | |
| DISPLAY | Parameter may be specified at statement level and/or at element level. | ||
| Applicable command | none | ||
Notes:
LCU is identical to
                               the session parameter LC. The difference is that
                               the leading characters are always stored in Unicode format. This allows you to
                               specify leading characters with mixed characters from different code pages, and
                               assures that always the correct character is displayed independent of the
                               installed system code page.
                  LCU and
                               ICU are mutually
                               exclusive.
                  See also:
Parameters to Influence the Output of Fields in the Programming Guide