Natural System Error Messages 1650-1699

NAT1678: Private mode in batch mode failed, reason :1:.

Text
Private mode in batch mode failed, reason ....
Explanation
Possible reasons:
 1 - Wrong environment: FSEC is incorrect.
 2 - Wrong environment: FUSER is incorrect.
 3 - LSO member has been illegally manipulated.
 4 - Environment cannot be established.
Actions:
Reason 1: Specify correct FSEC.
Reason 2: Specify correct FUSER.
Reason 3: Generate LSO container library again.
Reason 4: Natural provides additional error information;
          act according to this information.
Action
See above.

NAT1679: ONE private mode not allowed in NSC environment, reason :1:.

Text
ONE private mode not allowed in NSC environment, reason ....
Explanation
Possible reasons:
 1 - Private mode is disallowed.
 2 - Private mode library is assigned to another library.
 3 - Logon to private mode library is not allowed.
 4 - LSO library is defined with this ID.
 5 - Private mode library is defined as LSO library.
10 - LSO member is generated for another FSEC.
12 - LSO member has been manipulated.
Action
Contact your administrator.

NAT1681: NSF server communication error response :1:.

Text
NSF server communication error response ....
Explanation
Natural NSF - NSF server communication is not working.
Action
Please contact your administrator.

NAT1682: NSF :1: system error, reason :2:.

Text
NSF ... system error, reason ....
Explanation
A general problem has occurred.
Action
Please contact your administrator.

NAT1683: NSF: Logon to library :1: is denied.

Text
NSF: Logon to library ... is denied.
Explanation
You do not have the permission to log on to this library.
Possible reasons are:
- The access to the system files (FUSER/FDIC/FSEC/FNAT) was denied.
- The access to the library was denied.
Action
Contact your administrator.

NAT1684: Logon to library :1: failed. No access to steplib :2:.

Text
Logon to library ... failed. No access to steplib ....
Explanation
The logon is rejected due to missing access rights to steplibs
defined in the library profile.
Action
Contact your administrator.

NAT1685: User is revoked.

Text
User is revoked.
Explanation
No further explanation available.
Action
Contact your security administrator.

NAT1686: NSFSIZE parameter not specified or not available.

Text
NSFSIZE parameter not specified or not available.
Explanation
Either the NSFSIZE parameter was not specified
or NATGWSAF failed to acquire the storage specified by NSFSIZE.
Action
Ensure that the NSFSIZE parameter is specified correctly and
that the Natural region/thread is large enough.

NAT1687: Password change is currently not allowed.

NAT1688: User is temporarily locked, try again after :1:.

NAT1689: SSX error: user login failed, reason :1:.

Text
SSX error: user login failed, reason :1:.
Explanation
Cause of error as indicated by reason code shown in error message:
   1 - lenght of  user ID is max. 8 bytes.
.160 technical user credentials file error.
Action
Activate SSX log to get the error text.

NAT1690: Your password has expired :1: day(s) ago.

Text
Your password has expired ... day(s) ago.
Explanation
According to your security profile, you have to change your password
periodically. Your password has now expired.
Action
Change your password.

NAT1691: Your password will expire on :1:.

Text
Your password will expire on ....
Explanation
As of the date indicated in the message, your current password will no
longer be valid.
Action
Change your password.

NAT1692: User :1: is not authorized.

Text
User ... is not authorized.
Explanation
You have tried to log on to a library via Natural RPC in a client/server
environment. In the security profile of the library, the option
"Logon Option" (Natural RPC Restrictions) is set to "E" or "S". This
means that Natural Security checks if the Natural user ID used for
the access to the RPC server (for example, via user exit USR1071)
is identical to the EntireX user ID (supplied, for example, via user
exit USR2071).
This error message is issued if both user IDs are found to be not
identical.
Action
Contact your Natural administrator.

NAT1693: Password is too long (max. 8 characters are allowed).

Text
Password is too long (max. 8 characters are allowed).
Explanation
The maximum length allowed for the password is 8 characters.
Action
Please contact your security administrator.

NAT1694: Password changed successfully.

NAT1695: Logon to library :1: for user :2: denied, reason :3:, :4:.

Text
Logon to library ... for user ... denied, reason ..., ....
Explanation
Cause of error as indicated by reason code shown in error message:
   1 - This application is currently not available to you.
   2 - NAT0838: Change your password. Enter the old and a new password.
   3 - Logon to Natural RPC server and this library is not permitted.
  30 - NAT1692: User ... is not authorized.
  31 - ETID cannot be generated because ETID cannot be changed.
  32 - ETID generation failed for this user ID.
Action
Contact your Natural Security administrator.

NAT1696: Logon to library :1: for user :2: denied, reason :3:, :4:.

Text
Logon to library ... for user ... denied, reason ... ....
Explanation
Cause of error as indicated by reason code shown in error message:
   1 - NAT0873: User ID or password is invalid.
   2 - NAT0818: User is not found.
   7 - NAT0806: Library is not found.
   8 - NAT0807: Logon to library ID is denied.
   9 - NAT0963: Security violation during program execution.
  10 - RPC logon terminated by user.
  12 - Logoff from library failed.
  14 - Impersonation failed.
  16 - Internal error.
  20 - NAT0857: This user is currently locked.
  21 - NAT1685: This user is revoked.
  22 - NAT0812: User ID profile illegally manipulated.
  31 - NAT0807: Logon to library ID is denied in static mode.
Action
  31 - NAT0807: Logon to library ID is denied in static mode.
Contact your Natural Security administrator.

NAT1697: System file can only be accessed under Natural Security.

Text
System file can only be accessed under Natural Security.
Explanation
You have attempted to access a development server file whose security
has been activated in Natural Security. Access to such a file is only
possible in a Natural environment protected by Natural Security.
However, the Natural environment in which you have tried to access the
development server file is a non-Security environment.
Action
Please contact your Security administrator.

NAT1698: You are not authorized to execute the specified function.

Text
You are not authorized to execute the specified function.
Explanation
You are not authorized to execute the specified function.
Action
Please contact your Security administrator.

NAT1699: Automatic logon failed due to invalid default library.

Text
Automatic logon failed due to invalid default library.
Explanation
The default library is not correctly assigned to your user profile.
Action
Contact your Natural Security administrator.