This document covers the following topics:
On Windows, UNIX and OpenVMS platforms, Natural has internally been Unicode-enabled which means that many structures containing strings have Unicode format now. For example, the Natural source area has now Unicode format. For this reason, data which is only available in code page format is internally converted to Unicode format. This applies, for example, to the Natural sources and to the Natural library names and object names. However, a conversion from code page to Unicode and vice versa can only be performed successfully if the correct code page is used for conversion. Even if an application is not changed but only re-cataloged, the code page information is important because for cataloging an object is loaded into the Natural source area. If all objects are coded in the system code page, no changes are necessary. If the objects are not coded in the system code page, see Migrating Existing Objects on Windows, UNIX and OpenVMS Platforms for further information.
On Windows, the Natural output window has been Unicode-enabled which means that all fields have Unicode format now. In case of A format fields where the code page string length differs from the Unicode string length, the behavior of the Natural output window has changed slightly. This is especially relevant for double-byte code pages where the code page string length is normally twice as long as the Unicode string length. For A format input fields, it is now possible to enter "Unicode-string-length" characters in the field. When leaving the field and the default code page is a double-byte code page, all characters which do not fit into the target A format field are removed.
The internal Unicode structure will most probably need more memory. If
                        you have defined a low value for the profile parameter
                        USIZE, it
                        may be necessary to increase this value.
               
Natural has been extended so that the code page information can be defined on several levels:
The Natural profile parameter CP defines the default
                               Natural code page.
                     
For several objects (Natural sources, Natural batch input/output files, work files of type ASCII, ASCII compressed, Unformatted and CSV) an object-specific code page can be defined.
If neither an object-specific code page nor a default code page is defined, Natural will use the operating system's code page.
Since it is not possible to identify the correct code page automatically, it is important that you define the required code page information yourself. The following scenarios are possible:
| Status | Effort | Action | 
|---|---|---|
| All data is available in the operating system's code page. | No effort | No action. | 
| All data is stored with one code page, but this code page differs from the operating system's code page. | Easy | The Natural profile parameter
                                    CP has to be
                                    set to the correct code page. 
                         |  
                               
                     
| The data is available in different code pages. | Depends on the number of sources and code pages | The correct code page has to be defined for every
                                    Natural object: 
                                    
                           
  |  
                               
                     
| Different code pages are mixed in one object (for example, in a source) | High | The object has to be rewritten in UTF-8 format. | 
It is easy to extend existing applications with new source code based on the U format. The following rules have to be regarded for the U format (as compared with the A format):
A REDEFINE
                               of U to a format other than U should be avoided because this may result in
                               split characters.
                     
U format is endian-dependant. This has to be considered when moving between the formats B and U.
Align U in DEFINE
                                     DATA for performance reasons (better performance on UNIX and
                               OpenVMS).
                     
Keep in mind that characters may be lost when moving U to A.
If you want to change existing fields from A format to U format, the following rules have to be regarded:
Code which assumes a specific encoding of strings has to be changed (for example, comparison with a B field).
All REDEFINE statements of the
                               field have to be checked for their validity.
                     
A REDEFINE to N is not possible (that is: you will not
                               get the expected result).
                     
The database field has to be migrated to Unicode (provided that this is supported by your database).
You may have to change the length of the field: if the A field contains DBCS characters, half the length is required for the U field.
The profile parameter CP has been renamed to
                        CPRPC. In
                        earlier Natural versions, CP was used to specify the
                        name of the code page used by the Entire Conversion Service (ECS) and applied
                        only to the Natural RPC (Remote Procedure Call) when the transport protocol ACI
                        (that is, EntireX Broker) was used. 
               
A new CP parameter is
                        available which defines the default code page for Natural data. When you are
                        working with Natural RPC and have previously used the CP
                        parameter dynamically, you have to change this parameter to
                        CPRPC. 
               
When you use parameter files from a previous version, you need not
                        change anything; the Configuration
                           Utility automatically migrates CP to
                        CPRPC.