The Entire System Server Interface is required if the Entire System Server or Natural ISPF is to be used.
This document describes the steps for installing the Entire System Server Interface on z/VSE. You can choose between default installation (recommended) and customized installation.
For information on installing and using the Entire System Server or Natural ISPF, refer to the relevant product documentation.
When used in this document, the notation
vrs
or
vr
represents the relevant product
version (see also Version in the
Glossary).
A supported version of either of the following products must be installed before you can install the Entire System Server Interface:
Entire System Server or Natural ISPF, version as specified under Software AG Product Versions Supported by Natural in the current Natural Release Notes for Mainframes.
See also General Prerequisites and System Support in the section Overview of the Installation Process.
If you want to use the default value settings in the modules
ESYNODTB
and NATPNIP
(used by the Entire System
Server and Natural ISPF), proceed with
Link the Entire System
Server Interface to the Nucleus.
If you do not want to use the default value
settings, edit the modules NATPNIP
and
ESYNODTB
described in this section.
The NATPNIP
module contains the following parameters and
default values:
NAMVIEWP BUFLEN=12288,NUMREQ=5,MAXCBL=3000,MAXEDL=6000,EXTUSER=INIT-USER
The parameters are explained below:
BUFLEN |
Length of all Adabas buffers in bytes |
NUMREQ |
Number of possible nested FIND loops in Natural
calling the Entire System Server
|
MAXCBL |
Complex FIND buffer length
|
MAXEDL |
Editor session buffer length
The default value is 6000, which should be sufficient for an NSPF
editor session and typical incore database applications. However, for large
layouts within an incore database file that value might not be large enough and
the following message is issued:
In this case, the value of |
EXTUSER |
External user ID passed to the Entire System Server for
security checks
See also |
- EXTUSER
The parameter
EXTUSER
describes how to inherit security definitions from an external security system such as RACF, ACF2 and TOP-SECRET.The appropriate parameter setting depends on whether a multi-user address space or a single-user address space is used in your environment:
A multi-user address space provides the option to maintain different user security definitions, for example, one for a CICS and one for a Com-plete user).
A single-user address space supports a subsystem, for example, a Natural subtask for Entire Output Management or Entire Operations Management, or a Natural RPC, Natural Web/IO Interface or batch server.
Recommended values for
EXTUSER
are:
EXTUSER=INIT-USER
Recommended for a multi-user address space. The contents of the Natural system variable
*INIT-USER
must be identical to the user definition in the external security system (for example, RACF).The Entire System Server transfers the value of
*INIT-USER
to the external security system, and all calls to security restricted resources are handled under this user ID.In this case, the security definition from a CICS or Com-plete user (for example) is inherited by Entire System Server, and a new logon is not required. If the value of
*INIT-USER
is not found in RACF (for example), an error occurs indicating that a logon is required.(
*INIT-USER
is described in the System Variables documentation.)EXTUSER=USER
Recommended for a multi-user address space in a Natural Security environment. Processing is similar to
EXTUSER=INIT-USER
except that the Natural system variable*USER
(described in the System Variables documentation) is used.(
*USER
is described in the System Variables documentation.)EXTUSER=ADDRESS-SPACE
Recommended for a batch or server environment.
The security description of this address space is inherited for security evaluation.
The ESYNODTB
module contains the following parameters and
default values:
NAMXNOD ID=148,NAME=PRODUCTION-1 NAMXNOD ID=149,NAME=PRODUCTION-2 NAMXNOD ID=1490,NAME=DBID-ABOVE-255,LAST=Y END
The parameters and default values are explained below:
ID |
Entire System Server node number (also known as DBID) |
NAME |
Entire System Server node name |
LAST |
Indicator for last entry in table |
Calls to the Entire System Server from Natural are usually handled with
the NODE
parameter which specifies the node number to be used for
the call, for example:
FIND ACTIVE-JOBS WITH JOB-NAME = 'ADA*' AND NODE = 148
If the node number is defined in the ESYNODTB
module,
alternatively, you can specify the logical name of the required Entire System
Server with the NODE-NAME
parameter, for example:
FIND ACTIVE-JOBS WITH JOB-NAME = 'ADA*' AND NODE-NAME = 'PRODUCTION-2'
If Natural ISPF is used as the INCORE database:
(Job I055, Step 1106)
Link the parameter module NATPNIP
. In this case, the
module ESYNODTB
is not required.
If the Entire System Server is used:
(Job I055, Steps 1106, 1107)
Assemble and link the modules NATPNIP
(Step 1106), and,
optionally ESYNODTB
(Step 1107).
(Job I060, Step 3720)
Link the following Entire System Server Interface modules to either
the environment-independent
nucleus or the environment-dependent nucleus by
using the corresponding INCLUDE
statements:
INCLUDE NATPNIP |
Entire System Server Interface parameters |
INCLUDE ESXNUC |
Entire System Server Interface module |
INCLUDE ESYNODTB |
Optional, node table |
If you want to use the Write-to-Spool feature, either link the access
method to your nucleus or load the method dynamically. See also the Natural
parameters RCA
and RCALIAS
.
You can define and assemble the defaults for your nucleus by using the
source member NATPWSDF
before linking the defaults to the nucleus.
You can find the source member NATPWSDF
in the source library of
Natural.
The default settings of source member NATPWSDF
are as
follows:
NAMPWSPL NODE=148, PROGRAM=, CLASS=A, HOLD=YES, CNTL=A, FORM=, RMT=, FORMDEF=, PAGEDEF=
The table below shows the modifiable parameters of source member
NATPWSDF
and a detailed description of these parameters:
Parameter | Description | ||||||
---|---|---|---|---|---|---|---|
Node
|
NPR target node.
The node number can consist of up to 5 digits. It addresses the destination started task of the Entire System Server and where the output is written. |
||||||
Program
|
JES Writer which can contain up to
8 characters.
JES provides control to the Writer program. If JES does not find it, it is ignored. Possible value: |
||||||
Class
|
SYSOUT class within
JES where the output has to be written. It can contain only one character or
digit.
It is a descriptor for further software (for example, Entire Output Management) to detect the output stream for processing. |
||||||
Hold = yes/no
|
Specifies whether the output stream is to be held within the JES spool in case the task previously started by the Entire System Server terminates. | ||||||
CNTL |
|
||||||
FormRMT
|
Describes the form control buffer
for JES. This value is transferred to JES which handles the processing.
You can find the name of the JES system in the destination field
within the |
||||||
|
Can contain up to 6 characters. |
After editing the NATPWSDF
source member with customized
values, you can assemble and link it. If you want to use the default settings,
you can omit this step.
If you want to use the Write-to-Spool feature with statically linked access method at your site, relink the Natural module as follows:
INCLUDE NATPWSPL The Write-to-Spool access method for Natural INCLUDE NATPWSDF The Write-to-Spool defaults (your adapted parameter module)
If you want to use dynamic load, you can either use the delivered
module NATPWSAM
with default parameters or you can link your
adapted parameter module.
The output is written into the POWER
spool under a new job
number. The name of the printed spool data set will be the name of the
original batch job or the user ID of the TP monitor.
For further information, see System Spool Access in the Operations documentation.