Natural System Error Messages 7051-7100

NAT7051: The product license key is invalid.

Text
The product license key is invalid.
Explanation
The license key defined in the product license module does not match
the other data in the module. Either the data or the key has been
modified or generated incorrectly.
Action
Generate and link a correct license module. If you have no
correct license file, please contact Software AG.

NAT7052: The product license is not for :1:.

Text
The product license is not for ....
Explanation
The product license is not valid for ... , which can be one of the
following:

- product code "NAT"
- product major and minor version "AA.II" (Natural m(A)jor version AA,
                                                   m(I)nor version II);
- operating system "zOS", "zVSE", "zVM" or "BS2000".
Action
Check the product version and the operating system in your
license file. If you do not have a license file that matches your
environment, contact Software AG.

NAT7053: The product license has expired on :1:.

Text
The product license has expired on ....
Explanation
The product license has expired on ... (YYYY/MM/DD) and is no longer
valid. The session cannot start without a valid product license.
Action
Generate and link a correct license module. If you have no
correct license file, please contact Software AG.

NAT7055: CPU-ID :1: is not defined in your product license.

Text
CPU-ID ... is not defined in your product license.
Explanation
The serial number ... of your CPU is not defined in your product
license.
Action
Please contact Software AG and request a valid license file for
your CPUs.

NAT7056: LPAR name :1: is not defined in your product license.

Text
LPAR name ... is not defined in your product license.
Explanation
The price model in your license is 'LPAR', but the current name ... of
your system does not match one of the LPARs defined in your license.
Action
Please contact Software AG and request a valid license file for
your LPARs.

NAT7057: Machine capacity :1: higher than MSUs in product license.

Text
Machine capacity ... higher than MSUs in product license.
Explanation
The current capacity ... of your machine or partition is higher
than the machine service units (MSUs) defined by the <MSU> tag
in your product license.
Action
Contact Software AG and request a license file with a MSU value
according your requirements.

NAT7058: The product license will expire on :1:.

Text
The product license will expire on ....
Explanation
Your product license has the expiration date ... (YYYY/MM/DD).


Warning:
After this date, Natural cannot be started with this license.
Action
Please contact Software AG and request a new license file with
another or without an expiration date.

NAT7059: CPU-ID :1: assumed as your DR or DR testing environment.

Text
CPU-ID ... assumed as your DR or DR testing environment.
Explanation
The serial number ... of your CPU is not defined in your product
license. A Disaster Recovery (DR) scenario is assumed.
Action
Contact Software AG and request a valid license file for
your disaster recovery CPUs.

NAT7060: Tag :1: missing in product license.

Text
Tag ... missing in product license.
Explanation
The indicated tag is missing in your product license.
Action
Please contact your sales representative and request a valid
product license file which contains the indicated tag.

NAT7061: Invalid tag value :1: in product license.

Text
Invalid value for tag :1: in product license.
Explanation
The value of the indicated tag in your product license is invalid.
Action
Contact your sales representative and request a valid
product license file which contains a correct value for the
indicated tag.

NAT7062: Current CPU-ID not found for product license check.

Text
Current CPU-ID not found for product license check.
Explanation
The current CPU-ID of your machine cannot be located.
Action
Please contact Software AG support for further problem investigation.

NAT7063: Incorrect number of MSU values in product license.

Text
Incorrect number of MSU values in product license.
Explanation
The number of items in the <MSU> list does not correspond to the number
of CPU-IDs in the <CPUIDs> list.
Action
Contact Software AG and request a valid license file which
contains the same number of MSUs and CPU-IDs.

NAT7064: Extended Rights setting :1: not allowed under this system.

Text
Extended Rights setting ... not allowed under this system.
Explanation
The Extended Rights setting ... in your product license is not
allowed under your operating system or operating-system version.
It can be used only under z/OS 1.11 and above.
Action
Please contact Software AG and request a valid license file for
your operating system.

NAT7065: Soft capping is not allowed with <ExtendedRights> LP1.

Text
Soft capping is not allowed with <ExtendedRights> LP1.
Explanation
The tag <ExtendedRights> in your product license is set to LP1.
This setting is not allowed, because your operating system runs
with soft capping.
Action
Please contact Software AG and request a valid license file for
your operating system, or switch off soft capping.

NAT7069: Internal LICMAIN error :1:.

Text
Internal LICMAIN error :1:.
Explanation
During the check of your product license a severe error has
been detected. It can be one of the following:
- Invalid LCPCB length
- Work area too small
- Invalid function code or operating system
- Invalid product code, product version or current date
- Tag not found
- Component ID tag not found
- Invalid search tag
- Insufficient I/O area size
- Output record length too small
- Error message text not found
- Too many errors occurred
Action
Contact Software AG support for further problem investigation.

NAT7070: :1: zIIP support successfully enabled.

Text
... zIIP support successfully enabled.
Explanation
Natural zIIP support was successfully enabled. 'Advanced' means, that
Natural runs on zIIP as often as possible. 'Standard' means, that only
some parts of Natural, e.g. XML parsing, run on zIIP. Currently this
mode is not supported.
Action
None.

NAT7071: zIIP support not enabled due to :1:.

Text
zIIP support not enabled due to ....
Explanation
The Natural zIIP support cannot be enabled due to one of the following:

NATASM   The Natural Authorized Service Manager is not active or
         it of an old version which does not have zIIP support.
LICVAL   The length of the NAZ license is invalid.

LICERR   The NAZ license check has failed.

MEMORY   Not enough memory to allocate the zIIP work area.

NATVER   The Natural nucleus does not correspond to the version of
         the Authorized Service Manager (NATASM82).
Action
NATASM: Ensure that the latest NATASM is installed and active
        and the SUBSID profile parameter is set correctly.
LIC...: Request a correct license file from Software AG and install it.

NAT7072: Natural zIIP support not activated due to NAZ license errors.

Text
Natural zIIP support not activated due to NAZ license errors.
Explanation
The zIIP license check has found one or more errors, which are
shown following this message. Therefore the Natural zIIP support cannot
be activated.
Action
Your NAZ license is unsufficient for the current environment. Please
check the following license check errors for more information.

NAT7073: Defined hardware class in the license exceeded (:1:).

Text
Defined hardware class in the license exceeded (...).
Explanation
Your machine exceeds the hardware class defined in your zIIP license.
The machine type is indicated at the end of the message.
Action
Please contact Software AG and request a valid license file for
your machine type.

NAT7074: The number of zIIPs (:1:) exceeds the license definition.

Text
The number of zIIPs (...) exceeds the license definition.
Explanation
Your machine has more zIIP processors than allowed by the zIIP
license definition. The actual number of zIIPs is indicated in
the message.
Action
Please contact Software AG and request a valid license file which
has defined a sufficient number of zIIPs for your machine.