The Software AG Editor is an optional Natural component that is required by several Natural utilities (for example, SYSRPC and SYSBPM), Natural add-on products (for example, Natural ISPF) and other Software AG products (for example, Predict).
This document describes the steps for installing the Software AG Editor on z/OS.
For operational information, see Operating the Software AG Editor in the Operations documentation.
For information on the features and functions of the Software AG Editor, see the relevant section in the Editors documentation.
When used in this document, the notation
vrs
or
vr
represents the relevant product
version (see also Version in the
Glossary).
See General Prerequisites and System Support in the section Overview of the Installation Process.
The Software AG Editor must run without a buffer pool to support a Parallel Sysplex environment under CICS, that is, to be able to switch the z/OS host during a Natural session.
For this purpose, the Natural profile parameter
EDPSIZE
(described in the Parameter Reference documentation) is
supplied where you can specify the size of an auxiliary editor buffer pool. All
editor data is kept in the user storage thread. The total editor work space per
user is limited by the EDPSIZE
parameter. No editor work
file is required. The recovery feature mechanism of the Software AG Editor is
not supported.
Be sure to read Installation Process and Major Natural Features before you start the installation procedure.
The System Maintenance Aid
(SMA) parameter SAG-EDITOR
is set to Y
(Yes) by default to allow installation of the Software AG
Editor.
Modify the editor buffer pool settings supplied with the
NTEDBP
macro in the Natural parameter module to meet your requirements. For a
description of this macro, see the corresponding dynamic profile parameter
EDBP
.
Assemble the Natural parameter module and link it to the Software AG
Editor work file formatting utility (NATEDFM
) contained in the Natural load library.
The Software AG Editor work file formatting utility is described in
Editor Work
File in the Operations
documentation.
The editor buffer pool parameters contained in the Natural parameter module are stored in the editor buffer pool work file control record during formatting (see Step 3: Format the Editor Work File).
You can leave the defaults. In this case, it is not necessary to assemble and link the Natural parameter module.
(Job I008, Steps 1900, 1901, 1903, 1905)
Under Com-plete, this step is only required if you want to use a global editor buffer pool.
A VSAM RRDS is used as the editor work file. To best exploit the VSAM data set space, the record length should be defined 8 bytes less than the control interval length; see also Editor Work File in the Operations documentation.
Depending on your TP monitor environment, execute the following steps to allocate the data set:
Step 1900 ALLOCATE EDITOR WORK FILE BATCH 1901 ALLOCATE EDITOR WORK FILE CICS 1903 ALLOCATE EDITOR WORK FILE TSO 1905 ALLOCATE EDITOR WORK FILE GLOBAL
(Job I081, Steps 1900, 1901, 1903, 1905)
Under Com-plete, this step is only required if you want to use a global editor buffer pool.
Use the Software AG Editor work file formatting utility (NATEDFM
) to format and load the control record
in the editor work file.
Depending on your TP monitor environment, execute the following steps to format the data set:
Step 1900 FORMAT EDITOR WORK FILE BATCH 1901 FORMAT EDITOR WORK FILE CICS 1903 FORMAT EDITOR WORK FILE TSO 1905 FORMAT EDITOR WORK FILE GLOBAL
You may receive error message IEC070I 203-204
,
which can be ignored.
You can specify the data set for the work file by using the
keyword subparameter DSNAME
or
DDNAME
of
the parameter macro NTEDBP
(see EDBP - Software AG Editor
Buffer Pool Definitions in the Parameter
Reference documentation).
The data set name specified with
DDNAME
must correspond to the data set definition in your JCL.
Add a DD statement for the work file:
//CMEDIT DD DSN=data-set-name,DISP=SHR
where data-set-name
is the
name of the data set to be used for the work file.
You can skip this step if you have specified the correct data set name in the editor buffer pool's parameter macro in the Natural parameter module; Natural then allocates the file dynamically.
If you want to use a global editor buffer pool, add a DD statement for the editor work file:
//dd-name DD DSN=data-set-name,DISP=SHR
where:
dd-name
is the name of
the work file to be used by the global editor buffer pool,
data-set-name
is the
name of the data set to be used for the work file.
In addition, the DD name has to be defined to Com-plete by using the UUTIL utility function FM (described in the relevant section of the Com-plete documentation).
If you want to use a local editor buffer pool, define an SD file as
the editor work file. The name of the SD file is indicated in the keyword
subparameter DDNAME
of
the NTEDBP
macro. Therefore, the keyword subparameter
DSNAME
has no significance.
The number of work file records is set with the keyword
subparameter RECNUM
and the work file record length is set with the keyword subparameter
LRECL
of
the NTEDBP
macro.
For a local editor buffer pool, add the definitions of the editor
buffer pool to the SERVER
parameter of your startup
parameters as indicated in Define the Natural
Com-plete/SMARTS Interface Server in the section
Installing Natural Com-plete/SMARTS Interface.
For explanations of the keyword subparameters and macros mentioned above, see EDBP - Software AG Editor Buffer Pool Definitions in the Parameter Reference documentation.
Add an entry in the CICS File Control Table (Job I005).
(Job I080)
Add the following parameter to your Natural parameter module to specify the size of the editor area:
SSIZE=nn
where nn
must be set to at
least 54 (the default is 64).
The Software AG Editor requires either a local or a global editor buffer pool (see also Natural Buffer Pools in the Operations documentation).
Under IMS TM, the use of a global editor buffer pool is mandatory.
If you want to use a local editor buffer pool, specify the
NTBPI
macro as follows:
NTBPI TYPE=EDIT
The size of the region must be large enough to allocate the local buffer pool.
For more information on NTBPI
, see
NTBPI Macro
Syntax in the Parameter Reference
documentation.
If you want to use a global editor buffer pool, proceed as follows:
Specify the NTBPI
macro as follows:
NTBPI TYPE=EDIT,NAME=gbp-name
where gbp-name
is the name
of the global editor buffer pool to be used.
Supply the following parameter with the
NTPRM
macro
(described in the Operations documentation):
SUBSID=subsystem-name
where subsystem-name
is the
name of the Natural subsystem specified when creating the global buffer
pool.
For detailed information on SUBSID
, see
SUBSID - Subsystem ID under z/OS
and z/VSE in the Parameter Reference
documentation.
Assemble and link the Natural parameter module.
The global editor buffer pool can be shared by several regions. It is
defined and started using the same procedure as for Natural global buffer
pools; see Natural Global Buffer Pool
under z/OS in the
Operations documentation. The parameter setting
TYPE=EDIT
identifies the buffer pool as an editor buffer pool.
All users of the same global editor buffer pool must share the same editor work file; otherwise, an error occurs.
(Job I080)
Link the following Software AG Editor module to either the
environment-independent
nucleus or the environment-dependent nucleus by
using the corresponding INCLUDE
statement:
INCLUDE NATLIB(NATEDT)
Instead of linking the Software AG Editor module to the nucleus, you
can dynamically load it during initialization of a Natural session. In this
case, the NATEDT
editor module must be linked as
EDITOR
load module and the Natural session must be started with
the profile parameter setting RCA=EDITOR
(see also
RCA - Resolve Addresses of Statically
Linked Modules described in the Parameter
Reference documentation).
You can verify the successful installation of the Software AG Editor by performing the following:
Invoke Natural and enter the following system command:
SYSEDT
The SYSEDT Utility Main Menu appears, which can be used to display all buffer pool parameters and usage statistics; see SYSEDT Utility - Editor Buffer Pool Administration in the Utilities documentation.
You can only test the full operation of the Software AG Editor if another Software AG product (for example, Natural ISPF or Predict) that uses Software AG Editor functionality is installed.