This document describes the steps for installing Natural Security (product code NSC) on BS2000/OSD.
For information on the features and functions provided by Natural Security, see the Natural Security documentation.
When used in this document, the notation
vrs
or
vr
represents the relevant product
version (see also Version in the
Glossary).
See General Prerequisites and System Support in the section Overview of the Installation Process.
In addition to the prerequisites referred to above, the following software must be installed to use Natural Security in a heterogeneous environment:
Entire Net-Work
Natural Security for Mainframes
The following software must be installed as required:
Natural Security for UNIX
Natural Security for Windows
Natural Security for OpenVMS
For further information, see Using Natural Security on Multiple Platforms in the Natural Security documentation.
The installation medium contains the following files required for product installation:
File Name | Contents |
---|---|
NSCvrs.SYSL |
Natural Security log file |
NSCvrs.INPL |
Natural objects |
Copy the files into your environment as described in Copying Files to a BS2000/OSD Disk in the section Installing Natural.
Sample installation jobs are contained in the NATvrs.JOBS
file
and are prefixed with the product code. The file is provided on the
installation medium supplied for base Natural.
Be sure to read Installation Process and Major Natural Features before you start the installation procedure.
When you repeat a Natural Security installation, only the Natural
objects are replaced; the Natural Security data defined for SYSSEC
and DBA
is not reset to the values defined after the
initial installation. You can use the
function of the Natural
INPL utility to reset
the data.
This section describes the actual installation steps:
(Job I050, Step 9900)
Skip this step if you want to use an existing Natural FSEC
system file.
Load the new Natural FSEC
system file definition:
Set the System Maintenance Aid (SMA) parameter
NSC-FIRST-INSTALL
to Y
(Yes). This is the default
setting.
Specify the database ID and file number of the Adabas file where to
load the FSEC
system file by using the Adabas ADALOD utility.
In addition, you must specify this database ID and file number in the Natural parameter module as described in Step 4: Build the Natural Parameter Module.
Load the FSEC
system file definition contained in the
NATvrs.SYSF
file by using the
Adabas ADALOD utility.
The following ADALOD utility parameter must not be changed:
ISNREUSE=YES
(Job I050, Step 9901)
This step only applies if Adabas is installed and if the Natural Security function (see the Natural Security documentation) is to be used. It creates the log file to be used by the function.
Load the log file by using the Adabas ADALOD utility. Input for
ADALOD is the NSCvrs.SYSL
file.
(Job I050, Step 9902)
This step only applies if Adabas is installed and if the Natural Security function (see the Natural Security documentation) is to be used. It creates the logon and error log file to be used by the function.
Load the logon and error log file by using the Adabas ADALOD utility.
Input for ADALOD is the NATvrs.SYSF
file.
(Jobs I060, I080)
Specify the following profile parameter in your Natural parameter module:
FSEC=(database-id,file-number)
where database-id
and
file-number
are the database ID and
file number of either the new FSEC
system file loaded in
Step 1 or your existing
FSEC
system file.
The FSEC
profile parameter is described in the Parameter Reference
documentation.
Repeat Job I080 for all your TP monitors.
Assemble and link your Natural parameter module.
(Job I061, Step 0102 or Step 9900)
- For the migration installation (Step 0102):
Set the System Maintenance Aid (SMA) parameter
NSC-FIRST-INSTALL
toN
(No). The default setting isY
(Yes).Load the Natural objects specific to Natural Security from the
NSCvrs.INPL
file into the appropriate Natural libraries in yourFNAT
system file by using the Natural INPL utility.Once this step has been performed, it is not possible to remove Natural Security from the Natural system file; to remove Natural Security from the system file, you would have to delete the entire contents of the system file and reinstall all Natural components again.
- For the initial installation (Step 9900):
Set the System Maintenance Aid (SMA) parameter
NSC-FIRST-INSTALL
toY
(Yes).Load the Natural objects specific to Natural Security from the
NSCvrs.INPL
file into the appropriate Natural libraries in yourFNAT
system file by using the Natural INPL utility.When you load the contents of the
NSCvrs.INPL
file for the first time, this step creates the following security profiles and relationships:
A library security profile with the library ID
SYSSEC
. The library is people-protected ( set toY
and set toN
).A user security profile with the user ID
DBA
, the user type Administrator, and the password set toDBA
.The user
DBA
is linked to the librarySYSSEC
(ordinary link, no special link).
Natural Security is operational after Step 5: Load New Natural Objects of the Installation Procedure has been completed successfully.
For the initial installation, proceed as described in the section First Steps After the Installation in the Natural Security documentation. If you upgrade from a previous Natural Security version, you can skip the steps described in this section.