Natural provides the option to customize the default settings of your current Object Handler utility environment. For this purpose, Natural provides the text member OBJHPROF in the Natural system library SYSOBJH. OBJHPROF is used to specify environment-specific default values for flags and options that appear when entering the corresponding Object Handler screens.
To activate individual profile settings
In online mode, enter the Object Handler internal command
PROFILE
(or SHOW
PROFILE
).
This command invokes the Profile Maintenance tool that
displays a map with the general or user-specific profile parameters and their current values;
creates a new Object Handler profile with default values used internally in case an Object Handler profile does not exist;
allows you to modify general settings for the profile parameters in the Object Handler profile (controlled by Natural Security);
allows you to modify user-specific settings for the profile parameters in the Object Handler profile (controlled by Natural Security);
provides a description and help information for each profile parameter.
Enter PF4 to toggle user profile settings. You can use a Line Command to add, modify, or delete parameters from the user-specific profile.
Anmerkungen:
UPDATE
updates the changes into the Object
Handler profile. For more information, invoke Help.
To deactivate individual profile settings
Delete the text object OBJHPROF from the library SYSOBJH.
The remainder of this Dokument covers:
The following PF keys are available:
PF key | Description |
---|---|
PF1 (Help) | Invoke general or context-sensitive help. |
PF2 (Print) | Print the current profile settings. |
PF3 (Exit) | Save the profile data and terminate the Profile Maintenance tool. |
PF4 (Gener/User) | Toggle between general (Gener) and user-specific (User) profile settings. |
PF5 (Modif) | Modify the parameter (marked by cursor selection) in a separate menu. |
PF6 (--) | Scroll to the beginning of the parameter list. |
PF7 (-) | Scroll one page backwards. |
PF8 (+) | Scroll one page forward. |
PF9 (++) | Scroll to the end of the parameter list. |
PF10 (ALLDU/ALLAU) | For every parameter: insert line command
DU or AU .
|
PF12 (Canc) | Terminate the Profile Maintenance tool. |
The following line commands are available :
Line Command | Description |
---|---|
MO | Modify parameter value in extended mode. |
AU | Add entry to user profile |
DU | Delete entry from user profile |
DI | Display description of the parameter |
HE | Display help information on the parameter |
The table below lists the parameters contained in the Object Handler profile OBJHPROF, the possible values that can be entered and the Object Handler functions to which the parameters apply. In addition, the table provides a brief description of the parameters or a reference to the corresponding Object Handler documentation section. Default parameter values are underlined.
Parameter | Possible Values | Function |
Description/ |
||||||
---|---|---|---|---|---|---|---|---|---|
Input-Mode |
W |
Unload |
Wizards | ||||||
A |
Advanced User | ||||||||
C |
Compact Mode | ||||||||
Display-Cmd-in-Advanced-Mode |
|
Unload |
Displays the Object Handler command generated for a function executed in advanced-user mode. | ||||||
Display-ExecutionMsg |
|
Unload |
Activates a window that displays the processing status. | ||||||
Display-Statistics |
|
Unload |
Displays statistics on objects processed after the function has
been executed. (equivalent to direct command SHOW
STATISTICS ).
|
||||||
Workplan-Library |
|
Unload |
Workplans and |
||||||
Workplan-Library-DBID |
|
Unload |
|||||||
Workplan-Library-FNR |
|
Unload |
|||||||
TRACE |
|
Unload |
Traces in
Tools |
||||||
TRACE-TARGET |
|
Unload |
|||||||
Option-Replace |
|
Load |
Replace Options in Settings |
||||||
Option-TRANSFER-FORMAT |
|
Unload |
Work File Format in Work Files |
||||||
Option-Use-PC-Work-File |
|
Unload |
See
Use PC File in Set Additional Options |
||||||
Option-TR-INCLUDE-LINE-NUMBERS |
|
Unload | Include line numbers in
Transfer Options (Settings) |
||||||
Option-TR-LINE-NUMBER-INCREMENT |
|
Unload |
USE-LINE-NUMBER-INCREMENT in Transfer Options (Direct Commands) |
||||||
Option-TR-SUBSTITUTE |
|
Unload |
Substitute line
references in Transfer Options
(Settings) |
||||||
Option-TR-TRANSLATE-TO-UPPER |
|
Load |
Translate to upper
case in Transfer
Options(Settings) |
||||||
Option-TR-USE-CONVERSION-TABLE |
|
Unload |
Use conversion
table in Transfer Options
(Settings) |
||||||
Option-TR-CONV-TABLE-NAME-LOAD |
|
Load |
Use conversion
table in Transfer Options
(Settings) |
||||||
Option-TR-CONV-TABLE-NAME-UNLD |
|
Unload |
Use conversion
table in Transfer Options
(Settings) |
||||||
Option-TR-DA-FORMAT |
|
Unload |
Data
area format in Transfer
OptionsOptions |
||||||
Option-TR-UNICODE-WORK-FILE |
|
UNLOAD |
Unicode work file in Settings Screen Fields |
||||||
Option-TR-LOAD-CODE-PAGE |
|
LOAD |
Use load code page in Tansfer Options (Settings) |
||||||
Option-Write-Report |
|
Unload |
Reports in Tools Write report in Work File and Report Options |
||||||
Default-Report-Direct-Command
|
|
Unload |
Defines the kind of report to be written when a direct command
is executed and no report option is specified in the Object Handler command.
|
||||||
Default-Report-Option-1 |
|
Unload |
Defines the option for the report to be written when a direct
command is executed and option REPORT-OPTION-1 is not specified in
the Object Handler command. For possible values, see
REPORT-OPTION-1 .
|
||||||
Default-Report-Format |
|
Unload |
Defines the format of the report to be written when a direct
command is executed and option REPORT-FORMAT is not specified in
the Object Handler command. For possible values, see
REPORT-FORMAT .
|
||||||
Default-Report-Mode |
|
Unload |
Defines the report mode to be used when a direct command is
executed and option REPORT-MODE is not specified in the Object
Handler command. For possible values, see
REPORT-MODE .
|
||||||
Option-Write-Restart-Info |
|
Load |
Write restart information in Work File and Report Options |
||||||
USE-OPTION-WORKPLAN |
|
Unload |
Workplans | ||||||
OPTION-WORKPLAN-Name |
|
Unload |
Workplans | ||||||
USE-PARAMETER-WORKPLAN |
|
Unload |
Workplans | ||||||
PARAMETER-WORKPLAN-Name |
|
Unload |
Workplans | ||||||
WORK-FILE-1-Name |
The work file used for the PC file (Work File 7). |
Unload |
Work
Files
Only applies if Entire Connection is installed. |
||||||
Report-File-Name |
The name of the text member in the Workplan library to be used for the report. |
Unload |
Write report in Work File and Report Options |
||||||
Restart-File-Name |
The name of the text member in the Workplan library to be used for the restart information. | Load |
Write restart information in Work File and Report Options |
||||||
Trace-File-Name |
The name of the text member in the Workplan library to be used for the trace. | All functions |
Traces in Tools |
||||||
DELETE-TEMPORARY-REPORT-TEXT |
|
Unload Load Scan | Valid on mainframe only: Y = temporary text members
for the report are deleted when the Object Handler is terminated (default
value) N = temporary text members for the report are not deleted
when the Object Handler is terminated
|