This Dokument describes the tasks that must be accomplished to allow download and upload.
In order to download and upload data, a work file must be designated as a PC file.
To download reports, a printer must be designated as a PC printer.
To display your current work file and printer settings, enter
the Natural system command SYSFILE
at
the NEXT
prompt. This invokes the
SYSTP
utility
and a screen similar to the following appears:
11:07:18 ***** NATURAL SYSTP UTILITY ***** 2005-06-16 User SAG - Work File Information - TID DAEFTCI7 M No. Type Name Recfm Lrecl Blksz Status ------------------------------------------------------------------------------ 1 COMPLETE CMWKF01 VB 4628 Available for Input/Output 2 COMPLETE CMWKF02 VB 4628 Available for Input/Output 3 COMPLETE CMWKF03 VB 4628 Available for Input/Output 4 COMPLETE CMWKF04 VB 4628 Available for Input/Output 5 PC VB 4628 Available for Input/Output 6 PC VB 4628 Available for Input/Output 7 PC VB 4628 Available for Input/Output Top of List Command ===> Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12--- Cont Help Menu Exit Sel Pos -- - + ++ Print Work Canc |
The standard PC files are work files 5, 6 and 7 as shown in the example above. For more information, see SYSTP Utility in the Utilities documentation.
You can define work files and printers statically in your Natural parameter module, or dynamically when invoking Natural:
Work Files
Use the NTWORK
macro or WORK
parameter for
work file definitions.
Printers
Use the NTPRINT
macro or PRINT
parameter for
printer definitions.
For detailed information on these macros and parameters, see the Parameter Reference.
Remember, however, that the download and upload modules provided by Natural Connection use work file 7. For further information on transferring Natural objects, see Data Transfer which is part of the Terminal Emulation section of the Entire Connection documentation.
To upload and download data to/from a PC, the PC connection must be active. You activate the PC connection from the mainframe.
To activate the PC connection
Use the Natural terminal command %+
.
Oder:
Invoke Natural with the dynamic parameter
PC=ON
.
Oder:
Use the SET CONTROL
'+'
statement in a Natural program.
With the terminal command %+
, you can also
set an additional option:
Option | Description |
---|---|
%+N |
The PC connection is activated. In addition, no field names are sent when downloading or uploading data. |
If you attempt to upload or download data without the PC connection being activated, a message appears indicating that the PC connection is not active.
If you enter %+
and the PC connection is
already active, a message appears indicating that the PC connection is already
active.
To deactivate the PC connection
Use the Natural terminal command %-
.
Oder:
Use the SET CONTROL
'-'
statement in a Natural program.