This document describes the installation steps for enabling the use of
the Natural statements REQUEST DOCUMENT
and PARSE XML
on z/VSE.
For information on the functions provided by REQUEST
DOCUMENT
and PARSE XML
, see the following documents:
Statements for Internet and XML Access in the Programming Guide
REQUEST
DOCUMENT
in the Statements
documentation
PARSE XML
in
the Statements documentation
The following requirements must be met to execute the REQUEST
DOCUMENT
and PARSE XML
statements:
The ICU library must be installed to convert data from one encoding to another (at least internally). For details, see the relevant section in the Unicode and Code Page Support documentation.
A TCP/IP stack must be available and enabled for the execution environment.
A DNS (Domain Name System) server or DNS services must be available in
the execution environment to resolve internet addresses
(gethostbyname
function).
For Internet Protocol Version 6 (IPv6) support, the following additional prerequisites apply:
An activated IPv6 stack must be available on the local host.
The local network must support IPv6.
An accessible and IPv6-capable DNS server must be available.
For IPv6 internet communication, an IPv6 connection from the service provider must be available.
If both IPv4 and IPv6 are used, a dual stack must be supported.
IPv6 support must be configured with the appropriate keyword
subparameters of the Natural profile parameter
XML
described in the Parameter Reference documentation.
See also General Prerequisites and System Support in the section Overview of the Installation Process.
Be sure to read Installation Process and Major Natural Features before you start the installation procedure.
The installation procedure comprises the following:
The module NATXML
is required to execute
the statements REQUEST DOCUMENT
and PARSE XML
. If you want the PARSE XML
statement to support IBM
architecture level 9, alternatively, you can use the module
NATXMLA9
. See also PARSE XML Support for Architecture
Levels.
Set the System
Maintenance Aid (SMA) parameter NATXML
to
Y
(default is N
).
The NATXML
module is then linked to the
environment-independent
nucleus by using the following INCLUDE
statement:
INCLUDE NATXML
Or:
For support of IBM architecture level 9:
Set the SMA
parameters NATXML
and
NAT-ARCHLEVEL9
to Y
(default is
N
).
The alternative NATXMLA9
module is then linked to the
environment-independent
nucleus by using the following INCLUDE
statement:
INCLUDE NATXMLA9
The REQUEST DOCUMENT
and PARSE XML
statements
require the IBM Language Environment (LE) for
execution. If you want Natural to run in the IBM Language
Environment (LE), perform the following steps:
Set the System
Maintenance Aid (SMA) parameter NAT-LE
to
Y
(Yes). The default setting is N
(No).
Additionally, if you want to modify the LE options in the
NATLEOPT
source module or if you use non-Natural programs running
in 24-bit mode, set the appropriate SMA parameter as described in
Build the Natural-Specific IBM
Language Environment Options in Installing
Natural.
Link the environment-dependent nucleus to support LE.
This applies to all batch and TP monitor system environments except Com-plete.
Link the modules indicated in this section to the nucleus depending on the environment to be used.
Add the LE library (usually PRD2.SCEEBASE
) to the
OBJ-SEARCH
definition of the link job to resolve the references to
LE functions.
Link the following LE and TCP/IP access modules to the
environment-dependent
nucleus by using the appropriate INCLUDE
statement:
INCLUDE NAT2LE
Do not specify the NOAUTO
parameter
in the ACTION
statement for the link step.
If you run z/VSE Version 5 Release 1 (or above) and use a BSI TCP/IP Version 2.5.2 stack (or above), use the following statement:
INCLUDE NAT2TCP
If no such z/VSE versions and BSI TCP/IP stack versions are available, use the following statement:
INCLUDE NAT2TCP4
Link the following LE access module to the
environment-dependent
nucleus by using the appropriate INCLUDE
statement:
INCLUDE NAT2LE
Copy the NCFTCPvr
phase to
the Com-plete/SMARTS load library.
For support of the IBM TCP/IP stack, define the CDI (Communication Driver Interface) as described in Standard CDI Definitions in the Com-plete documentation.
Add the POSIX SERVER
statement to the Com-plete
parameter module SYSPARM
.
The architecture level (the higher the better) you can use depends on the IBM hardware facility installed at your site.
The following architecture levels can be specified with the PARSE
XML
statement, International Components for
Unicode for Software (ICS) and/or the
Natural Optimizer Compiler
(NOC):
Level Value | Supported By | IBM Hardware Facility Required |
---|---|---|
0 |
All | Specifies that no architecture level is used. This is the default setting for compatibility with all mainframe platforms supported by Natural. |
1 to 4 |
All | These values are not evaluated and treated as
ARCH=0 .
|
5 to 6 |
NOC only |
|
7 |
NOC only |
|
8 |
NOC only |
|
9 |
PARSE XML and ICS only |
|
10 |
NOC only |
|
11 |
NOC only |
|
Warnung: An operation exception error (abend code S0C1) can occur if code generated with an architecture level greater than 0 is executed on
a machine where the corresponding hardware facility is not
installed. |
After the last step of the installation procedure has been completed, proceed as follows:
Activate the statements in the runtime environment; see Activation/Deactivation in the section Statements for Internet and XML Access in the Programming Guide.
For information on the profile settings that enable the support of the
REQUEST DOCUMENT
and/or PARSE XML
statement, see the following documents:
Profile Settings in the section Statements for Internet and XML Access in the Programming Guide
Profile parameter XML
in the
Parameter Reference documentation
Try the example programs contained in the Natural system library
SYSEXV
.