This section lists error messages you may receive when working with the Natural Web Server Extensions.
Error Number | Error Message | Description | User | Programmer | Administrator |
---|---|---|---|---|---|
NWW0001 | No library and subprogram specified. | The specified URL is not correct. Names of library and subprogram are missing. | Correct the URL. | None. | None. |
NWW0002 | No library specified. | The specified URL is not correct. | Correct the URL. | None. | None. |
NWW0003 | File ... not found. | The initialization file for your adapter cannot be found. | None. | None. | Check your installation. |
NWW0004 | No subprogram specified. | The specified URL is not correct. | Correct the URL. | None. | None. |
NWW0010 | RPC call failed. | EntireX RPC cannot be initialized. | None. | None. | Check installation. |
NWW0011 | ERX error ... occurred ... |
Internal ERX error. See EntireX Communicator documentation for further information. If the error contains the following part:
Message: The called program does not work. |
Correct URL. | Check and stow your program. | Check installation. |
NWW0012 | ERX error register. | EntireX RPC Service cannot be initialized. | None. | None. | Check configuration. |
NWW0013 | erx.dll cannot be loaded. Subcode: .... | EntireX Communicator erx.dll not found. | None. | None. | Check installation. |
NWW0014 | ERX logon failed. | EntireX Communicator logon cannot be performed. | Check User-ID, Password | Check installation file for Check User-ID, Password. | Check installation. |
NWW0015 | ERX logoff failed. | Logoff from EntireX Communicator failed. | None. | None. | Contact Software AG. |
NWW0033 | File ... not found (Error: ...). | The initialization file for your adapter cannot be found. | None. | None. | Check your obj.conf setup for NSAPI. |
NWW0034 | NWW_USER_ID too long. | User ID only with a maximum of 8 characters allowed. | None. | None. | Specify only user IDs with 8 characters or fewer, even if other system will allow more. |
NWW0035 | NWW_PASSWORD too long. | Passwords only with a maximum of 8 characters allowed. | None. | None. | Specify only (user-) passwords with 8 characters or fewer, even if other system will allow more. |
NWW0036 | Natural Library Name too long. | Natural allows only library names up to 8 characters. | Check URL. | Check URL specification. | None. |
NWW0037 | Natural Subprogram Name too long. | Natural allows only Subprogram names up to 8 characters. | Check URL. | Check URL specification. | None. |
NWW0099 | CONTENT_TYPE: ... is not supported. | Only data with CONTENT_TYPE = application/x-www-form-urlencoded is supported. | None. | Do not use the attribute ENCTYPE at your FORM tag. | None. |
NWW0100 | RPC_INOUT_LENGTH is greater than 30000. |
The output returned to the HTTP server is limited to restrictions of Natural RPC. Note: |
None. | None. | Change configuration. |
NWW0101 | Number of parameters is greater than 200. |
The input parameter given from the HTTP server is limited to 200 parameters. Note: |
None. | Reduce number of parameters transferred to the Web Interface. | None. |
NWW0200 | No Header specified. | Each page needs a header section at the return page. | None. | Each page should contain a CONTENT_TYPE. The header section has to be separated from the data by a blank line. | None. |
NWW0201 | Page contains no Data. | Every return page has to contain data. | None. | Correct the program. | None. |
NWW0815 | Interface A1(1:v) no longer supported. | Wrong interface specified. | None. | None. |
Remove |
NWW1001 | No class and method specified. | The specified URL is not correct. Names of class and method are missing. | Correct the URL. | None. | None. |
NWW1002 | No class specified. | The specified URL is not correct. | Correct the URL. | None. | None. |
NWW1004 | No method specified. | The specified URL is not correct. | Correct the URL. | None. | None. |
NWW1005 | ASCII Unicode conversion failed. | The transferred data has to be converted. | None. | None. | Contact Software AG. |
NWW1006 | Unicode ASCII conversion failed. | The transferred data has to be converted. | None. | None. | Contact Software AG. |
NWW1007 | Method ... not found. | A specified method cannot be called. | Correct the URL. | Add method to your class. | Check your registry configuration. |
NWW1008 | Class ... not found. | A specified class cannot be called. | Correct the URL. | Create class and register with REGISTER * | Check your registry configuration. |
NWW1009 | Initialization of Class ... failed. | A specified class cannot be called. | Correct the URL. | Create class and register with REGISTER * | Check your registry configuration. |
NWW1010 | DCOM call failed, error .... | The call to DCOM failed. | None. | None. | Check your configuration. |
NWW1011 | DCOM error ... occurred ... | Internal DCOM error. See DCOM documentation for further information. | Correct the URL. | Correct the program. | Correct the Congiguration/Installation. |
NWW1012 | DCOM initialization failed. | The initial call to DCOM failed. | None. | None. | Correct the Configuration/Installation. |
NWW1013 | DCOM release failed. | The deletion of class and close of DCOM failed. | None. | None. | Correct the Configuration/Installation. |
NWW1036 | DCOM Class Name too long. | Natural allows only library names up to 32 characters. | Check the URL. | Check the URL specification. | None. |
NWW1037 | DCOM Method Name too long. | Natural allows only subprogram names up to 32 characters. | Check the URL. | Check the URL specification. | None. |