Version 6.3.8 für Windows
 —  Natural for Ajax  —

TEXT

The TEXT control represents a multi line text edit control. It represents the value of an adapter parameter.

The following topics are covered below:


Properties

Basic
valueprop

Name of the adapter parameter that provides the content of the control.

Obligatory  
width

Width of the control.

There are three possibilities to define the width:

(A) You do not define a width at all. In this case the width of the control will either be a default width or - in case of container controls - it will follow the width that is occupied by its content.

(B) Pixel sizing: just input a number value (e.g. "100").

(C) Percentage sizing: input a percantage value (e.g. "50%"). Pay attention: percentage sizing will only bring up correct results if the parent element of the control properly defines a width this control can reference. If you specify this control to have a width of 50% then the parent element (e.g. an ITR-row) may itself define a width of "100%". If the parent element does not specify a width then the rendering result may not represent what you expect.

Sometimes obligatory

100

120

140

160

180

200

50%

100%

height

Height of the control.

There are three possibilities to define the height:

(A) You do not define a height at all. As consequence the control will be rendered with its default height. If the control is a container control (containing) other controls then the height of the control will follow the height of its content.

(B) Pixel sizing: just input a number value (e.g. "20").

(C) Percentage sizing: input a percantage value (e.g. "50%"). Pay attention: percentage sizing will only bring up correct results if the parent element of the control properly defines a height this control can reference. If you specify this control to have a height of 50% then the parent element (e.g. an ITR-row) may itself define a height of "100%". If the parent element does not specify a width then the rendering result may not represent what you expect.

Optional

100

150

200

250

300

250

400

50%

100%

flush

Flushing behaviour of the input control.

By default an input into the control is registered within the browser client - and communicated to the server adapter object when a user e.g. presses a button. By using the FLUSH property you can change this behaviour.

Setting FLUSH to "server" means that directly after changing the input a synchronization with the server adapter is triggered. As consequence you directly can react inside your adapter logic onto the change of the corresponding value. - Please be aware of that during the synchronization always all changed properties - also the ones that were changed before - are transferred to the adapter object, not only the one that triggered the synchonization.

Setting FLUSH to "screen" means that the changed value is populated inside the page. You use this option if you have redundant usage of the same property inside one page and if you want to pass one changed value to all its representaion directly after changing the value.

Optional

screen

server

flushmethod

When the data synchronization of the control is set to FLUSH="server" then you can specify an explicit event to be sent when the user updates the content of the control. By doing so you can distinguish on the server side from which control the flush of data was triggered.

Optional  
datatype

By default, the control is managing its content as string. By explicitly setting a datatype you can define that the control will format the data coming from the server: if the field has datatype "date" and the user inputs "010304" then the input will be translated into "01.03.2004" (or other representation, dependent on date format settings).

Please note: the datatype "float" is named a bit misleading - it represents any decimal format number. The server side representation may be a float value, but also can be a double or a BigDecimal property.

Optional  
comment

Comment without any effect on rendering and behaviour. The comment is shown in the layout editor's tree view.

Optional  
Appearance
width (already explained above)    
displayonly

If set to true, the FIELD will not be accessible for input. It is just used as an output field.

Optional

true

false

direction

Presets the default(BiDi) direction of the control. Use black string in order to have the default value.

Optional

rtl

ltr

displayprop

Name of the adapter parameter that dynamically passes information whether the field is displayonly(true) or not (false).

Optional  
statusprop

Name of the adapter parameter that dynamically passes information how the control should be rendered and how it should act. Use DISPLAYPROP to dynamically define whether the field is displayonly.

Optional  
wrap

Specifies the line wrapping inside the control. By default a line that exceeds the width of the control is broken automatically.

You may define this property to not wrap at all ("off") - in this case the text control offers horizontal scroll bars to scroll the text.

There are two styles of wrapping "soft" and "hard". The difference between "soft" and "hard" is the way the text is - if changed by the user - passed back to the adapter property: when specifying "soft" then line breaks which are caused by wrapping are not sent to the server, when specifying "hard" then line breaks caused by wrapping are sent as carriage return/ line feed. - Be carefule when specifying "hard" as consequence!

Optional

soft

hard

off

rows

Height of control specified by number of rows. Either define the height by the HEIGHT property or by the ROWS property. Do not specify both!

When specifying the height by ROWS then be aware of that the height depends from the font size used inside the control (that is defined in the styles sheet definition).

Optional  
cols

Width of control specified by number of characters. Either define the width by the WIDTH property or by the COLS property. Do not specify both!

When specifying the width by COLS then be aware of that the width depends from the font size used inside the control (that is defined in the styles sheet definition).

Optional  
colspan

Column spanning of control.

If you use TR table rows then you may sometimes want to control the number of columns your control occupies. By default it is "1" - but you may want to define the control to span over more than one columns.

The property only makes sense in table rows that are snychronized within one container (i.e. TR, STR table rows). It does not make sense in ITR rows, because these rows are explicitly not synched.

Optional

1

2

3

4

5

50

int-value

maxlength

Maximum number of characters that a user may enter into this FIELD. This property is not depending on the LENGTH property - please do not get confused by the similar naming. MAXLENGTH has nothing to do with the optical sizing of the control but only with the number of characters you may input.

Optional

5

10

15

20

int-value

maxlengthprop

Name of the adapter parameter that provides the maximum number of characters that a user may enter into this FIELD. Consider to use MAXLENGTH to define this number in a static way.

Optional  
rowspan

Row spanning of control.

If you use TR table rows then you may sometimes want to control the number of rows your control occupies. By default it is "1" - but you may want to define the control two span over more than one columns.

The property only makes sense in table rows that are snychronized within one container (i.e. TR, STR table rows). It does not make sense in ITR rows, because these rows are explicitly not synched.

Optional

1

2

3

4

5

50

int-value

textareastyle

CSS style definition that is directly passed into this control.

With the style you can individually influence the rendering of the control. You can specify any style sheet expressions. Examples are:

border: 1px solid #FF0000

background-color: #808080

You can combine expressions by appending and separating them with a semicolon.

Sometimes it is useful to have a look into the generated HTML code in order to know where direct style definitions are applied. Press right mouse-button in your browser and select the "View source" or "View frame's source" function.

Optional  
title

Text that is shown as tooltip for the control.

Either specify the text "hard" by using this TITLE property - or use the TITLETEXTID in order to define a language dependent literal.

Optional  
titletextid

Text ID that is passed to the multi lanaguage management - representing the tooltip text that is used for the control.

Optional  
titleprop

Name of the adapter parameter that dynamically defines the title of the control. The title is displayed as tool tip when ther user moves the mouse onto the control.

Optional  
scroll

Definition of the scrollbar's appearance.

You can define that the scrollbars only are shown if the content is exceeding the control's area ("auto"). Or scrollbars can be shown always ("scroll"). Or scrollbars are never shown - and the content is cut ("hidden").

Default is "auto".

Optional

auto

scroll

hidden

tabindex

Index that defines the tab order of the control. Controls are selected in increasing index order and in source order to resolve duplicates.

Optional

-1

0

1

2

5

10

32767

Online Help
helpid

Help id that is passed to the online help management in case the user presses F1 on the control.

Optional  
title (already explained above)    
titletextid (already explained above)    
titleprop (already explained above)    
Natural
njx:natstringtype

If the control shall be bound to a Natural system variable of string format with the attribute njx:natsysvar, this attribute indicates the format of the string, A (code page) or U (Unicode). The default is A.

Optional  
njx:natsysio

If the control shall be bound to a Natural system variable with the attribute njx:natsysvar, this attribute indicates if the system variable is modifiable. The default is false.

Optional  
njx:natname

If a Natural variable with a name not valid for Application Designer (for instance #FIELD1) shall be bound to the control, a different name (for instance HFIELD1) can be bound instead. If the original name (in this case #FIELD1) is then specified in this attribute, the original name is generated into the parameter data area of the Natural adapter and a mapping between the two names is generated into the PROCESS PAGE statement of the Natural adapter.

Optional  
njx:natsysvar

If the control shall be bound to a Natural system variable, this attribute specifies the name of the system variable.

Optional  
njx:natcomment

The value of this attribute is generated as comment line into the parameter data area of the Natural adapter, before the field name. The Map Converter, for instance, uses this attributes to indicate for a generated statusprop variable to which field the statusprop belongs.

Optional  
njx:natcv

Name of a Natural control variable that shall be assigned to the control. The control variable must be defined in a Data Definition (XCIDATADEF) control on the same page. The application can use the control variable to check the modification status of the control.

Optional  
Miscellaneous
testtoolid

Use this attribute to assign a fixed control identifier that can be later on used within your test tool in order to do the object identification

Optional  