Screen Design

This document provides options to define a general screen layout:


Control of Function-Key Lines - Terminal Command %Y

With the terminal command %Y you can define how and where the Natural function-key lines are to be displayed.

Below is information on:

Format of Function-Key Lines

The following terminal commands are available for defining the format of function-key lines:

%YN

 The function-key lines are displayed in tabular Software AG format:

  Command ===>
  Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12---
        Help        Exit                                                  Canc 
%YS

The function-key lines display the keys sequentially and only show those keys to which names have been assigned (PF1=value, PF2=value, etc.):

  Command ===>                                                                   
  PF1=Help,PF3=Exit,PF12=Canc
%YP

The function-key lines are displayed in PC-like format, that is, sequentially and only showing those keys to which names have been assigned (F1=value, F2=value, etc.):

  Command ===>                                                                   
  F1=Help,F3=Exit,F12=Canc

Other Display Options

Various other command options are available for function-key lines, such as:

  • single- and double-line display,

  • intensified display,

  • reverse video display,

  • color display.

For details on these options, see %Y - Control of PF-Key Lines in the Terminal Commands documentation.

Positioning of Function-Key Lines

%YB

The function-key lines are displayed at the bottom of the screen.

%YT

The function-key lines are displayed at the top of the screen.

%Ynn

The function-key lines are displayed on line nn of the screen.

Cursor-Sensitivity

%YC

This command makes the function-key lines cursor-sensitive. This means that they act like an action bar on a PC screen: you just move the cursor to the desired function-key number or name and press Enter, and Natural reacts as if the corresponding function key had been pressed.

To switch cursor-sensitivity off, you enter %YC again (toggle switch).

By using %YC in conjunction with tabular display format (%YN) and having only the function-key names displayed (%YH), you can equip your applications with very comfortable action bar processing: the user merely has to select a function name with the cursor and press Enter, and the function is executed.

Control of the Message Line - Terminal Command %M

Various options of the terminal command %M are available for defining how and where the Natural message line is to be displayed.

Below is information on:

Positioning the Message Line

%MB

The message line is displayed at the bottom of the screen.

%MT

The message line is displayed at the top of the screen.

Other options for the positioning of the message line are described in %M - Control of Message Line in the Terminal Commands documentation.

Message Line Color

%M=color-code

The message line is displayed in the specified color (for an explanation of color codes, see the session parameter CD as described in the Parameter Reference).

Assigning Colors to Fields - Terminal Command %=

You can use the terminal command %= to assign colors to field attributes for programs that were originally not written for color support. The command causes all fields/text defined with the specified attributes to be displayed in the specified color.

If predefined color assignments are not suitable for your terminal type, you can use this command to override the original assignments with new ones.

You can also use the %= terminal command within Natural editors, for example to define color assignments dynamically during map creation.

Codes Description
blank Clear color translate table.
F Newly defined colors are to override colors assigned by the program.
N Color attributes assigned by program are not to be modified.
O Output field.
M Modifiable field (output and input).
T Text constant.
B Blinking
C Italic
D Default
I Intensified
U Underlined
V Reverse video
BG Background
BL Blue
GR Green
NE Neutral
PI Pink
RE Red
TU Turquoise
YE Yellow

Example:

%=TI=RE,OB=YE

This example assigns the color red to all intensified text fields and yellow to all blinking output fields.

Infoline - Terminal Command %X

The terminal command %X controls the display of the Natural infoline.

For further information, see the description of the terminal command %X in the Terminal Commands documentation.

    Windows

    Below is information on:

    What is a Window?

    A window is that segment of a logical page, built by a program, which is displayed on the terminal screen.

    A logical page is the output area for Natural; in other words the logical page contains the current report/map produced by the Natural program for display. This logical page may be larger than the physical screen.

    There is always a window present, although you may not be aware of its existence. Unless specified differently (by a DEFINE WINDOW statement), the size of the window is identical to the physical size of your terminal screen.

    You can manipulate a window in two ways:

    • You can control the size and position of the window on the physical screen.

    • You can control the position of the window on the logical page.

    Positioning on the Physical Screen

    The figure below illustrates the positioning of a window on the physical screen. Note that the same section of the logical page is displayed in both cases, only the position of the window on the screen has changed.

    Physical screen

    Positioning on the Logical Page

    The figure below illustrates the positioning of a window on the logical page.

    When you change the position of the window on the logical page, the size and position of the window on the physical screen will remain unchanged. In other words, the window is not moved over the page, but the page is moved "underneath" the window.

    Logical page

    DEFINE WINDOW Statement

    You use the DEFINE WINDOW statement to specify the size, position and attributes of a window on the physical screen.

    A DEFINE WINDOW statement does not activate a window; this is done with a SET WINDOW statement or with the WINDOW clause of an INPUT statement.

    Various options are available with the DEFINE WINDOW statement. These are described below in the context of the following example.

    The following program defines a window on the physical screen.

    ** Example 'WINDX01': DEFINE WINDOW                                     
    ************************************************************************
    DEFINE DATA LOCAL                                                       
    1 COMMAND (A10)                                                         
    END-DEFINE                                                              
    *                                                                       
    DEFINE WINDOW TEST                                                      
           SIZE 5*25                                                        
           BASE 5/40                                                        
           TITLE 'Sample Window'                                            
           CONTROL WINDOW                                                   
           FRAMED POSITION SYMBOL BOTTOM LEFT                     
    *                                                                       
    INPUT WINDOW='TEST' WITH TEXT 'message line'                            
          COMMAND (AD=I'_') /                                               
          'dataline 1' /                                                    
          'dataline 2' /                                                    
          'dataline 3' 'long data line'                                     
    *                                                                       
    IF COMMAND = 'TEST2'         
      FETCH 'WINDX02'            
    ELSE                         
      IF COMMAND = '.'           
        STOP                     
      ELSE                       
        REINPUT 'invalid command'
      END-IF                     
    END-IF                       
    END
    

    The window-name identifies the window. The name may be up to 32 characters long. For a window name, the same naming conventions apply as for user-defined variables. Here the name is TEST.

    The window size is set with the SIZE option. Here the window is 5 lines high and 25 columns (positions) wide.

    The position of the window is set by the BASE option. Here the top left-hand corner of the window is positioned on line 5, column 40.

    With the TITLE option, you can define a title that is to be displayed in the window frame (of course, only if you have defined a frame for the window).

    With the CONTROL clause, you determine whether the PF-key lines, the message line and the statistics line are displayed in the window or on the full physical screen. Here CONTROL WINDOW causes the message line to be displayed inside the window. CONTROL SCREEN would cause the lines to be displayed on the full physical screen outside the window. If you omit the CONTROL clause, CONTROL WINDOW applies by default.

    With the FRAMED option, you define that the window is to be framed. This frame is then cursor-sensitive. Where applicable, you can page forward, backward, left or right within the window by simply placing the cursor over the appropriate symbol (<, -, +, or >; see POSITION clause) and then pressing Enter. In other words, you are moving the logical page underneath the window on the physical screen. If no symbols are displayed, you can page backward and forward within the window by placing the cursor in the top frame line (for backward positioning) or bottom frame line (for forward positioning) and then pressing Enter.

    With the POSITION clause of the FRAMED option, you define that information on the position of the window on the logical page is to be displayed in the frame of the window. This applies only if the logical page is larger than the window; if it is not, the POSITION clause will be ignored. The position information indicates in which directions the logical page extends above, below, to the left and to the right of the current window.

    If the POSITION clause is omitted, POSITION SYMBOL TOP RIGHT applies by default.

    POSITION SYMBOL causes the position information to be displayed in form of symbols: "More: < - + >". The information is displayed in the top and/or bottom frame line.

    TOP/BOTTOM determines whether the position information is displayed in the top or bottom frame line.

    LEFT/RIGHT determines whether the position information is displayed in the left or right part of the frame line.

    You can define which characters are to be used for the frame with the terminal command %F=chv.

    c The first character will be used for the four corners of the window frame.
    h The second character will be used for the horizontal frame lines.
    v The third character will be used for the vertical frame lines.

    Example:

    %F=+-!
    

    The above command makes the window frame look like this:

    +------------------------+
    !                        !
    !                        !
    !                        !
    !                        !
    +------------------------+
    

    INPUT WINDOW Statement

    The INPUT WINDOW statement activates the window defined in the DEFINE WINDOW statement. In the example, the window TEST is activated. Note that if you wish to output data in a window (for example, with a WRITE statement), you use the SET WINDOW statement.

    When the above program is run, the window is displayed with one input field COMMAND. The session parameter AD is used to define that the value of the field is displayed intensified and an underscore is used as filler character.

    Output of Program WINDX01:

    > r                                     > +  Program     WINDX01  Lib SYSEXPG  
    Top    ....+....1....+....2....+....3....+....4....+....5....+....6....+....7..
      0010 ** Example 'WINDX01': DEFINE WINDOW                                     
      0020 ******************************* +----Sample Window-----+ ***************
      0030 DEFINE DATA LOCAL               ! message line         !                
      0040 1 COMMAND (A10)                 ! COMMAND __________   !                
      0050 END-DEFINE                      ! dataline 1           !                
      0060 *                               +More:     + >---------+                
      0070 DEFINE WINDOW TEST                                                      
      0080        SIZE 5*25                                                        
      0090        BASE 5/40                                                        
      0100        TITLE 'Sample Window'                                            
      0110        CONTROL WINDOW                                                   
      0120        FRAMED POSITION SYMBOL BOTTOM LEFT                               
      0130 *                                                                       
      0140 INPUT WINDOW='TEST' WITH TEXT 'message line'                            
      0150       COMMAND (AD=I'_') /                                               
      0160       'dataline 1' /                                                    
      0170       'dataline 2' /                                                    
      0180       'dataline 3' 'long data line'                                     
      0190 *                                                                       
      0200 IF COMMAND = 'TEST2'                                                    
           ....+....1....+....2....+....3....+....4....+....5....+... S 29   L 1   
    

    In the bottom frame line, the position information More: + > indicates that there is more information on the logical page than is displayed in the window.

    To see the information that is further down on the logical page, you place the cursor in the bottom frame line on the plus (+) sign and press Enter.

    The window is now moved downwards. Note that the text long data line does not fit in the window and is consequently not fully visible.

    > r                                     > +  Program     WINDX01  Lib SYSEXPG  
    Top    ....+....1....+....2....+....3....+....4....+....5....+....6....+....7..
      0010 ** Example 'WINDX01': DEFINE WINDOW                                     
      0020 ******************************* +----Sample Window-----+ ***************
      0030 DEFINE DATA LOCAL               ! message line         !                
      0040 1 COMMAND (A10)                 ! dataline 3 long data !                
      0050 END-DEFINE                      ! dataline 2           !               
      0060 *                               +More:   -   >---------+                
      0070 DEFINE WINDOW TEST                                                      
      0080        SIZE 5*25                                                        
      0090        BASE 5/40                                                        
      0100        TITLE 'Sample Window'                                            
      0110        CONTROL WINDOW                                                   
      0120        FRAMED POSITION SYMBOL BOTTOM LEFT                               
      0130 *                                                                       
      0140 INPUT WINDOW='TEST' WITH TEXT 'message line'                            
      0150       COMMAND (AD=I'_') /                                               
      0160       'dataline 1' /                                                    
      0170       'dataline 2' /                                                    
      0180       'dataline 3' 'long data line'                                     
      0190 *                                                                       
      0200 IF COMMAND = 'TEST2'                                                    
           ....+....1....+....2....+....3....+....4....+....5....+... S 29   L 1   
    

    To see this hidden information to the right, you place the cursor in the bottom frame line on the less-than symbol (>) and press Enter. The window is now moved to the right on the logical page and displays the previously invisible word line:

    > r                                     > +  Program     WINDX01  Lib SYSEXPG  
    Top    ....+....1....+....2....+....3....+....4....+....5....+....6....+....7..
      0010 ** Example 'WINDX01': DEFINE WINDOW                                     
      0020 ******************************* +----Sample Window-----+ ***************
      0030 DEFINE DATA LOCAL               ! message line         !                
      0040 1 COMMAND (A10)                 !  line                ! <==
      0050 END-DEFINE                      !                      !                
      0060 *                               +More: < -    ---------+                
      0070 DEFINE WINDOW TEST                                                      
      0080        SIZE 5*25                                                        
      0090        BASE 5/40                                                        
      0100        TITLE 'Sample Window'                                            
      0110        CONTROL WINDOW                                                   
      0120        FRAMED POSITION SYMBOL BOTTOM LEFT                               
      0130 *                                                                       
      0140 INPUT WINDOW='TEST' WITH TEXT 'message line'                            
      0150       COMMAND (AD=I'_') /                                               
      0160       'dataline 1' /                                                    
      0170       'dataline 2' /                                                    
      0180       'dataline 3' 'long data line'                                     
      0190 *                                                                       
      0200 IF COMMAND = 'TEST2'                                                    
           ....+....1....+....2....+....3....+....4....+....5....+... S 29   L 1   
    

    Multiple Windows

    You can, of course, open multiple windows. However, only one Natural window is active at any one time, that is, the most recent window. Any previous windows may still be visible on the screen, but are no longer active and are ignored by Natural. You may enter input only in the most recent window. If there is not enough space to enter input, the window size must be adjusted first.

    When TEST2 is entered in the COMMAND field, the program WINDX02 is executed.

    ** Example 'WINDX02': DEFINE WINDOW                                     
    ************************************************************************
    DEFINE DATA LOCAL                                                       
    1 COMMAND (A10)                                                         
    END-DEFINE                                                              
    *                                                                       
    DEFINE WINDOW TEST2                                                     
           SIZE 5*30                                                        
           BASE 15/40                                                       
           TITLE 'Another Window'                                           
           CONTROL SCREEN                                                   
           FRAMED POSITION SYMBOL BOTTOM LEFT                               
    *                                                                       
    INPUT WINDOW='TEST2' WITH TEXT 'message line'                           
          COMMAND (AD=I'_') /                                               
          'dataline 1' /                                                    
          'dataline 2' /                                                    
          'dataline 3' 'long data line'                                     
    *                                                                       
    IF COMMAND = 'TEST' 
      FETCH 'WINDX01'            
    ELSE                         
      IF COMMAND = '.'           
        STOP                     
      ELSE                       
        REINPUT 'invalid command'
      END-IF                     
    END-IF                       
    END                         
    

    A second window is opened. The other window is still visible, but it is inactive.

    message line
    > r                                     > +  Program     WINDX01  Lib SYSEXPG  
    Top    ....+....1....+....2....+....3....+....4....+....5....+....6....+....7..
      0010 ** Example 'WINDX01': DEFINE WINDOW                                     
      0020 ******************************* +----Sample Window-----+ ***************
      0030 DEFINE DATA LOCAL               ! message line         !  Inactive
      0040 1 COMMAND (A10)                 ! COMMAND TEST2_____   !  Window
      0050 END-DEFINE                      ! dataline 1           !  <==
      0060 *                               +More:     + >---------+                
      0070 DEFINE WINDOW TEST                                                      
      0080        SIZE 5*25                                                        
      0090        BASE 5/40                                                        
      0100        TITLE 'Sample Window'                                            
      0110        CONTROL WINDOW                                                   
      0120        FRAMED POSITION SYMBOL B +------Another Window-------+  Currently         
      0130 *                               ! COMMAND __________        !  Active
      0140 INPUT WINDOW='TEST' WITH TEXT ' ! dataline 1                !  Window
      0150       COMMAND (AD=I'_') /       ! dataline 2                !  <==
      0160       'dataline 1' /            +More:   +------------------+           
      0170       'dataline 2' /                                                    
      0180       'dataline 3' 'long data line'                                     
      0190 *                                                                       
      0200 IF COMMAND = 'TEST2'                                                            
    

    Note that for the new window the message line is now displayed on the full physical screen (at the top) and not in the window. This was defined by the CONTROL SCREEN clause in the WINDX02 program.

    For further details on the statements DEFINE WINDOW, INPUT WINDOW and SET WINDOW, see the corresponding descriptions in the Statements documentation.

    Standard/Dynamic Layout Maps

    Standard Layout Maps

    A standard layout can be defined in the map editor. This layout guarantees a uniform appearance for all maps that reference it throughout the application.

    When a map that references a standard layout is initialized, the standard layout becomes a fixed part of the map. This means that if this standard layout is modified, all affected maps must be re-cataloged before the changes take effect.

    Dynamic Layout Maps

    In contrast to a standard layout, a dynamic layout does not become a fixed part of a map that references it, rather it is executed at runtime.

    This means that if you define the layout map as "dynamic" on the Define Map Settings For MAP screen in the map editor, any modifications to the layout map are also carried out on all maps that reference it. The maps need not be re-cataloged.

    For further details on layout maps, see Map Editor in the Editors documentation.

    Multilingual User Interfaces

    Using Natural, you can create multilingual applications for international use.

    Maps, helproutines, error messages, programs, functions, subprograms and copycodes can be defined in up to 60 different languages (including languages with double-byte character sets).

    Below is information on:

    Language Codes

    In Natural, each language has a language code (from 1 to 60). The table below is an extract from the full table of language codes. For a complete overview, refer to the description of the system variable *LANGUAGE in the System Variables documentation.

    Language Code Language Map Code in Object Names
    1 English 1
    2 German 2
    3 French 3
    4 Spanish 4
    5 Italian 5
    6 Dutch 6
    7 Turkish 7
    8 Danish 8
    9 Norwegian 9
    10 Albanian A
    11 Portuguese   B

    The language code (left column) is the code that is contained in the system variable *LANGUAGE. This code is used by Natural internally. It is the code you use to define the user language (see Defining the User Language below). The code you use to identify the language of a Natural object is the map code in the right-hand column of the table.

    Example:

    The language code for Portuguese is "11". The code you use when cataloging a Portuguese Natural object is "B".

    For the full table of language codes, see the system variable *LANGUAGE as described in the System Variables documentation.

    Defining the Language of a Natural Object

    To define the language of a Natural object (map, helproutine, program, function, subprogram or copycode), you add the corresponding map code to the object name. Apart from the map code, the name of the object must be identical for all languages.

    In the example below, a map has been created in English and in German. To identify the languages of the maps, the map code that corresponds to the respective language has been included in the map name.

    Example of Map Names for a Multilingual Application

    DEMO1 = English map (map code 1)

    DEMO2 = German map (map code 2)

    Defining Languages with Alphabetical Map Codes

    Map codes are in the range 1-9, A-Z or a-y. The alphabetical map codes require special handling.

    Normally, it is not possible to catalog an object with a lower-case letter in the name - all characters are automatically converted into capitals.

    This is however necessary, if for example you wish to define an object for Kanji (Japanese) which has the language code 59 and the map code x.

    To catalog such an object, you first set the correct language code (here 59) using the terminal command %L=nn, where nn is the language code.

    You then catalog the object using the ampersand (&) character instead of the actual map code in the object name. So to have a Japanese version of the map DEMO, you stow the map under the name DEMO&.

    If you now look at the list of Natural objects, you will see that the map is correctly listed as DEMOx.

    Objects with language codes 1-9 and upper case A-Z can be cataloged directly without the use of the ampersand (&) notation.

    In the example list below, you can see the three maps DEMO1, DEMO2 and DEMOx. To delete the map DEMOx, you use the same method as when creating it, that is, you set the correct language with the terminal command %L=59 and then confirm the deletion with the ampersand (&) notation (DEMO&).

    Defining the User Language

    You define the language to be used per user - as defined in the system variable *LANGUAGE - with the profile parameter ULANG (which is described in the Parameter Reference) or with the terminal command %L=nn (where nn is the language code).

    Referencing Multilingual Objects

    To reference multilingual objects in a program, you use the ampersand (&) character in the name of the object.

    The program below uses the maps DEMO1 and DEMO2. The ampersand (&) character at the end of the map name stands for the map code and indicates that the map with the current language as defined in the *LANGUAGE system variable is to be used.

    DEFINE DATA LOCAL  
    1 PERSONNEL VIEW OF EMPLOYEES
      2 NAME (A20) 
      2 PERSONNEL-ID (A8) 
    1 CAR VIEW OF VEHICLES
       2 REG-NUM (A15) 
    1 #CODE (N1)  
    END-DEFINE
    * 
    INPUT USING MAP 'DEMO&' /* <--- INVOKE MAP WITH CURRENT LANGUAGE CODE 
    ...
    

    When this program is run, the English map (DEMO1) is displayed. This is because the current value of *LANGUAGE is 1 = English.

                                                              MAP DEMO1   
                                                                                     
                                                                                     
                                    SAMPLE MAP                                     
                                                                                     
                                                                                     
                                                                                     
                                                                                     
                        Please select a function!                                    
                                                                                     
                                                                                     
                                                                                     
                        1.) Employee information                                     
                                                                                     
                        2.) Vehicle information                                      
                                                                                     
                                                                                     
                                                                                     
                        Enter code here: _
    

    In the example below, the language code has been switched to 2 = German with the terminal command %L=2.

    When the program is now run, the German map (DEMO2) is displayed.

                                    BEISPIEL-MAP                                   
                                                                                     
                                                                                     
                                                                                     
                                                                                     
                        Bitte wählen Sie eine Funktion!                              
                                                                                     
                                                                                     
                                                                                     
                        1.) Mitarbeiterdaten                                         
                                                                                     
                        2.) Fahrzeugdaten                                            
                                                                                     
                                                                                     
                                                                                     
                     Code hier eingeben: _
    

    Programs

    For some applications it may be useful to define multilingual programs. For example, a standard invoicing program, might use different subprograms to handle various tax aspects, depending on the country where the invoice is to be written.

    Multilingual programs are defined with the same technique as described above for maps.

    Error Messages

    Using the Natural utility SYSERR, you can translate Natural error messages into up to 60 languages, and also define your own error messages.

    Which message language a user sees, depends on the *LANGUAGE system variable.

    For further information on error messages, see SYSERR Utility in the Utilities documentation.

    Edit Masks for Date and Time Fields

    The language used for date and time fields defined with edit masks also depends on the system variable *LANGUAGE.

    For details on edit masks, see the session parameter EM as described in the Parameter Reference.

    Skill-Sensitive User Interfaces

    Users with varying levels of skill may wish to have different maps (of varying detail) while using the same application.

    If your application is not for international use by users speaking different languages, you can use the techniques for multilingual maps to define maps of varying detail.

    For example, you could define language code 1 as corresponding to the skill of the beginner, and language code 2 as corresponding to the skill of the advanced user. This simple but effective technique is illustrated below.

    The following map (PERS1) includes instructions for the end user on how to select a function from the menu. The information is very detailed. The name of the map contains the map code 1:

                                                              MAP PERS1       
                                                                                     
                                      SAMPLE MAP                                     
                                                                                     
                        Please select a function                                     
                                                                                     
                                                                                     
                        1.) Employee information  _                                  
                                                                                     
                        2.) Vehicle information   _                                  
                                                                                     
                            Enter code:  _                                           
                                                                                     
      To select a function, do one of the following:                                 
                                                                                     
      - place the cursor on the input field next to desired function and press Enter 
      - mark the input field next to desired function with an X and press Enter      
      - enter the desired function code (1 or 2) in the 'Enter code' field and press 
    Enter                                                                           
    

    The same map, but without the detailed instructions is saved under the same name, but with map code 2.

                                                          MAP PERS2       
                                                                                     
                                                                                     
                                      SAMPLE MAP                                     
                                                                                     
                        Please select a function                                     
                                                                                     
                                                                                     
                        1.) Employee information  _                                  
                                                                                     
                        2.) Vehicle information   _                                  
                                                                                     
                            Enter code:  _                                           
                                                                                    
    

    In the example above, the map with the detailed instructions is output, if the ULANG profile parameter has the value 1, the map without the instructions if the value is 2. See also the description of the profile parameter ULANG (in the Parameter Reference).