Version 4.2.6 for Mainframes
 —  Natural for Ajax  —

COMBOFIX

The COMBOFIX control is a selection control. Depending on its configuration, it is either displayed as a combo box or as a selection list.

The COMBOFIX control allows specifying a defined set of values which can be selected. This set of values is defined as part of the layout definition - it cannot be controlled dynamically by the application.

Note:
If you want to use dynamic selection, there are two possibilities. Either use the COMBODYN control which has the same look and feel as the COMBOFIX control, but where the selectable values are not specified as part of the page definition and are controlled by the application. Or use the value help popup dialogs.

The following topics are covered below:


COMBOFIX Properties

Basic
valueprop

Name of the adapter parameter that provides the content of the control.

Obligatory  
width

Width of the control.

There are three possibilities to define the width:

(A) You do not define a width at all. In this case the width of the control will either be a default width or - in case of container controls - it will follow the width that is occupied by its content.

(B) Pixel sizing: just input a number value (e.g. "100").

(C) Percentage sizing: input a percantage value (e.g. "50%"). Pay attention: percentage sizing will only bring up correct results if the parent element of the control properly defines a width this control can reference. If you specify this control to have a width of 50% then the parent element (e.g. an ITR-row) may itself define a width of "100%". If the parent element does not specify a width then the rendering result may not represent what you expect.

Optional

100

120

140

160

180

200

50%

100%

comment

Comment without any effect on rendering and behaviour. The comment is shown in the layout editor's tree view.

Optional  
Appearance
width (already explained above)    
size

Number of rows that are displayed inside the control. If specified as "1" (default) then the control is rendered as combo box - if ">1" then the control is rendered as multi line selection.

Optional  
displayonly

If set to true, the FIELD will not be accessible for input. It is just used as an output field.

Optional  
align

Horizontal alignment of control in its column.

Each control is "packaged" into a column. The column itself is part of a row (e.g. ITR or TR). Sometimes the size of the column is bigger than the size of the control itself. In this case the "align" property specifies the position of the control inside the column. In most cases you do not require the align control to be explicitly defined because the size of the column around the controls exactly is sized in the same way as the contained control.

If you want to directly control the alignment of text: in most text based controls there is an explicit property "textalign" in which you align the control's contained text.

Optional

left

center

right

valign

Vertical alignment of control in its column.

Each control is "packaged" into a column. The column itself is part of a row (e.g. ITR or TR). Sometimtes the size of the column is bigger than the size of the control. In this case the "align" property specify the position of the control inside the column.

Optional

top

middle

bottom

colspan

Column spanning of control.

If you use TR table rows then you may sometimes want to control the number of columns your control occupies. By default it is "1" - but you may want to define the control to span over more than one columns.

The property only makes sense in table rows that are snychronized within one container (i.e. TR, STR table rows). It does not make sense in ITR rows, because these rows are explicitly not synched.

Optional

1

2

3

4

5

50

int-value

rowspan

Row spanning of control.

If you use TR table rows then you may sometimes want to control the number of rows your control occupies. By default it is "1" - but you may want to define the control two span over more than one columns.

The property only makes sense in table rows that are snychronized within one container (i.e. TR, STR table rows). It does not make sense in ITR rows, because these rows are explicitly not synched.

Optional

1

2

3

4

5

50

int-value

combostyle

CSS style definition that is directly passed into this control.

With the style you can individually influence the rendering of the control. You can specify any style sheet expressions. Examples are:

border: 1px solid #FF0000

background-color: #808080

You can combine expressions by appending and separating them with a semicolon.

Sometimes it is useful to have a look into the generated HTML code in order to know where direct style definitions are applied. Press right mouse-button in your browser and select the "View source" or "View frame's source" function.

Optional  
invisiblemode

If the visibility of the control is determined dynamically by an adapter property then there are two rendering modes if the visibility is "false":

(1) "invisible": the control is not visible.

(2) "disabled": the control is deactivated: it is "grayed" and does not show any roll over effects any more.

Optional

invisible

cleared

tabindex

Index that defines the tab order of the control. Controls are selected in increasing index order and in source order to resolve duplicates.

Optional

-1

0

1

2

5

10

32767

Binding
valueprop (already explained above)    
displayprop

Name of the adapter parameter that dynamically passes information whether the field is displayonly(true) or not (false).

Optional  
statusprop

Name of the adapter parameter that dynamically passes information how the control should be rendered and how it should act. Use DISPLAYPROP to dynamically define whether the field is displayonly.

Optional  
flush

Flushing behaviour of the input control.

By default an input into the control is registered within the browser client - and communicated to the server adapter object when a user e.g. presses a button. By using the FLUSH property you can change this behaviour.

Setting FLUSH to "server" means that directly after changing the input a synchronization with the server adapter is triggered. As consequence you directly can react inside your adapter logic onto the change of the corresponding value. - Please be aware of that during the synchronization always all changed properties - also the ones that were changed before - are transferred to the adapter object, not only the one that triggered the synchonization.

Setting FLUSH to "screen" means that the changed value is populated inside the page. You use this option if you have redundant usage of the same property inside one page and if you want to pass one changed value to all its representaion directly after changing the value.

Optional

screen

server

flushmethod

When the data synchronization of the control is set to FLUSH="server" then you can specify an explicit event to be sent when the user updates the content of the control. By doing so you can distinguish on the server side from which control the flush of data was triggered.

Optional  
Online Help
helpid

Help id that is passed to the online help management in case the user presses F1 on the control.

Optional  
Miscellaneous
testtoolid

Use this attribute to assign a fixed control identifier that can be later on used within your test tool in order to do the object identification

Optional  

Top of page

COMBOOPTION Properties

Basic
name

Name that is displayed as selectable option. Either use the NAME property to specify the text in a "hard" way or use the TEXTID property to define the text in a language dependent way.

Optional  
textid

Text ID that is used for this option. The text id is passed to the multi language management in order to find a language dependent text.

Optional  
value

Actual value of the option that is passed into the adapter property specified by VALUEPROP inside the COMBOFIX control.

Optional  
comment

Comment without any effect on rendering and behaviour. The comment is shown in the layout editor's tree view.

Optional  

Top of page