Version 4.2.6
 —  Parameter-Referenz  —

PCNTRL - Print-Control Characters

This Natural profile parameter specifies the line-advance characters for printing which are inserted in Column 0 of each print line.

Possible settings Any character string This parameter can be specified in character or hexadecimal format.
Default setting Siemens Environments X'404142434445464748494A4B4C4D4E4F'
IBM Environments

The default setting (according to ASA standard settings) is:

' 0-'

which means that a blank causes a line advance of 1 line, "0" of 2 lines and "-" of 3 lines.

Warnung:
In any IBM environment, do not change the default setting of this parameter.
Dynamic specification yes  
Specification within session no  

Seitenanfang