This Natural profile parameter determines which access method is to be used for hardcopy output processing.
HCAM=xxx
is equivalent to the
AM
subparameter of the profile parameter
PRINT
for Print
File 0, that is,
PRINT=((0),AM=xxx)
.
You can specify one of the following access-method names:
Possible settings | Value: | Access method: |
---|---|---|
STD |
Standard sequential file (batch, TSO, TIAM, VM/CMS OS simulation). | |
COMP |
Com-plete print file. | |
CMS |
VM/CMS disk and SFS files. | |
CICS |
CICS transient data or temporary storage. | |
IMS |
IMS/TM printer. | |
NAF |
Natural Advanced Facilities. | |
USER |
Third-party vendor print interface. | |
SMARTS |
SMARTS print file. | |
ESS |
Entire System Server. | |
ANY |
Hardcopy output processing will be handled by the first access method available (the search sequence for available access methods is the sequence in which the access methods are listed here). | |
OFF |
Hardcopy output processing will not be handled by any access method. | |
Default setting | ANY |
|
Dynamic specification | yes | |
Specification within session | no |
The hardcopy output destination is specified using the profile parameter
HCDEST
. More
specifications for the hardcopy output file can be made using the
PRINT
profile
parameter or the NTPRINT
macro for Printer 0.
Note for BS2000/OSD Users:
HCAM=STD
is a necessary setting for routing hardcopy output to