The ABEND codes described here can occur during the operation of the Entire Transaction Propagator CICS Interface (product code: ETC).
If one of the following ABENDs occurs, it may be hidden if a CICS ABEND exit is set (e.g. within Natural). In any case, the error message is written to the operator console and to the CICS job log.
Code | Explanation |
---|---|
ETC0 | An ETC internal error occurred. Contact your Software AG support representative. |
ETC1 | The parameter module ETCPARM is not linked to ETC. |
ETC2 | ETPNUC has not been linked to ETC. |
ETC3 | The module specified in the ADANAME parameter of the ETCPARM macro call could not be loaded. |
ETC4 | The CICS level types of the module resulting from the linkage step and ADALNC must be the same. Both must be either command- or macro-level; a combination of the two is not allowed. |
ETC5 | The module specified in the ADANAME parameter of the ETCPARM macro call is not an ADALNC macro-level module from a supported Adabas version. |
ETC6 | The CICS version on which ETC was installed is not supported. |
ETC7 | The ETCNUC and ETCPARM versions do not match. |
ETC8, ETC9 | An ETC internal error occurred. Contact your Software AG support representative. |
ETCA | The TWA does not exist or the TWA length is not sufficient. |
ETCB | All PUSER slots are exhausted or the user-specific slot could not be found. |
ETCC | EXECKEY (CICS) has been set for ETC. EXECKEY (USER) must be set. |