Text | The GCMD call failed with status code :1:. |
Expl. | The failed GCMD call was used to retrieve the response segments for the command passed to IMS/TM. Module(s): CMCMMND |
Actn. | Contact your system programmer. |
Text | Module not allowed in non-conversational NATURAL sessions. |
Expl. | If you switch to a non-conversational non-NATURAL transaction, a message is required. Module(s): CMDIRNMZ |
Actn. | Check your environment. OR Use the appropriate switching program. |
Text | A program switch has been requested without a message. |
Expl. | If you switch to a non-conversational transaction, you must specify a message. Module(s): NIIDIRTX |
Actn. | Check the transaction code used. OR Use the appropriate switching module. |
Text | Invalid program switch while suspending the NATURAL session. |
Expl. | You may not switch between a conversational NATURAL session and a non-conversational transaction code using the Suspend function. Module(s): NIIDEFTX, NIIDIRTX |
Actn. | Check the transaction codes used. OR Do not use the Suspend function. |
Text | Message passed too large for input message buffer. |
Expl. | The length of the message passed is larger than the size of the input message buffer. Note: The input message buffer is used as I/O area when the below mentioned modules send the message to IMS/TM. Module(s): NIIDEFTX, NIIDIRTX |
Actn. | Check the length of the message passed to NIIDEFTX/NIIDIRTX. OR Increase the size of the input message buffer in the environment table (MISIZE parameter in the NIMPARM macro). |
Text | Invalid program switch to a non-NATURAL transaction. |
Expl. | You want to switch to a NATURAL transaction, but you have specified a non-NATURAL transaction code. Module(s): NIIDEFT, NIIDIRT |
Actn. | Check the transaction code used. OR Use the appropriate switching module. |
Text | You tried to retrieve data outside the SPA. |
Expl. | The area beginning at the specified offset in the specified length must reside entirely inside the SPA. Module(s): NIIGSPA |
Actn. | Correct the offset and/or length used in your program. |
Text | You tried to update data outside the SPA. |
Expl. | The area beginning at the specified offset in the specified length must reside entirely inside the SPA. Module(s): NIIPSPA |
Actn. | Correct the length and/or offset used in your program. |
Text | Logical PCB name not defined in transaction code table. |
Expl. | Each logical PCB name used must be defined in the transaction code table. Module(s): NIIPCBAD |
Actn. | Check the transaction code table. OR Correct the PCB name used in your program. |
Text | Not enough space for the command in the command buffer. |
Expl. | The length of the command passed is larger than the size of the command buffer. Note: The command buffer is used as I/O area when NIICMD sends the command to IMS/TM. Module(s): NIICMD |
Actn. | Check the length of the command passed to NIICMD. OR Increase the size of the command buffer in the environment table (CMBSIZE parameter in the NIMPARM macro). |
Text | The CMD call failed with status :1:. |
Expl. | The failed CMD call was used to send the command to IMS/TM. Module(s): NIICMD |
Actn. | Contact your system programmer. |
Text | The reply length may not be zero. |
Expl. | A non-zero reply length is required to retrieve response segments for a command passed to IMS/TM. Module(s): NIIGCMD |
Actn. | Correct the length used in your program. |
Text | The GCMD call failed with status code :1:. |
Expl. | The failed GCMD call was used to retrieve the response segments for the command passed to IMS/TM. Module(s): NIIGCMD |
Actn. | Contact your system programmer. |
Text | The CHNG call failed with status code :1:. |
Expl. | The failed CHNG call was used to set the destination of the first alternate TP PCB to the value passed. Note: The first alternate TP PCB must be modifiable. Module(s): CMQUEUE, CMQUEUEX, NIIDQUMS, NIIISRTF |
Actn. | Contact your system programmer. |
Text | The ISRT call failed with status code :1:. |
Expl. | The failed ISRT call was used to send the message segment to the destination set in the first alternate TP PCB. Module(s): CMQUEUE, CMQUEUEX, NIIDQUMS. NIIISRTF, NIIISRTM |
Actn. | Contact your system programmer. |
Text | The PURG call failed with status code :1:. |
Expl. | The failed PURG call was used to implicitely terminate the current message sent to the destination set in the first alternate TP PCB. Module(s): CMQUEUE, CMQUEUEX |
Actn. | Contact your system programmer. |
Text | The GU call failed with status code :1:. |
Expl. | The failed GU was used to retrieve the first message segment from the IMS/TM message queue. Module(s): CMGETMSG, NIIGMSG |
Actn. | Contact your system programmer. |
Text | Message received too large for message area provided. |
Expl. | The length of the message retrieved from the IMS/TM message queue is larger than the length of the message area provided by your program. Module(s): CMGETMSG, NIIGMSG |
Actn. | Increase the length of the message area used in your program. |
Text | Message passed too large for input message buffer. |
Expl. | The length of the message passed is larger than the size of the input message buffer. Note: The input message buffer is used as I/O area when the below mentioned modules send the message to IMS/TM. Module(s): NIIISRTF, NIIISRTM |
Actn. | Check length of message passed to NIIISRTF/NIIISRTM. OR Increase the size of the inout message buffer in the environment table (MISIZE parameter in NIMPARM macro). |
Text | The CHNG call failed with status code :1:. |
Expl. | The failed CHNG call was used to set the destination of the first alternate TP PCB to the value passed. Note: The first alternate TP PCB must be modifiable. Module(s): CMBRCAST, NIIBRCST |
Actn. | Contact your system programmer. |
Text | Message larger than output message buffer. |
Expl. | The length of the message passed is larger than the size of the output message buffer. Note: The output message buffer is used as I/O area when the below mentioned modules send the message to IMS/TM. Module(s): CMBRCAST, CMPUTMSG, CMQUEUE, CMQUEUEX, NIIDQUMS NIIBRCST, NIIPMSG |
Actn. | NIIBRCST, NIIPMSG Check length of message passed to
above-mentioned modules. OR Increase size of output message buffer in the environment table (MOSIZE parameter in NIMPARM macro). |
Text | The ISRT call failed with status code :1:. |
Expl. | The failed ISRT call was used to send the message segment to the destination set in the first alternate TP PCB resp. to the destination set in the IOPCB. Module(s): CMBRCAST, CMPUTMSG, NIIBRCST, NIIPMSG |
Actn. | Contact your system programmer. |
Text | The PURG call failed with status code :1:. |
Expl. | The failed PURG call was used to implicitely terminate the current message sent to the destination set in the first alternate TP PCB. Module(s): CMBRCAST, NIIBRCST |
Actn. | Contact you system programmer. |
Text | You tried to overwrite the header of the SPA. |
Expl. | The specified area must begin behind the SPA header. Module(s): NIIPSPA |
Actn. | Correct the offset used in your program. |
Text | Message segment received too large for input message buffer. |
Expl. | The length of the message segment retrieved from the IMS/TM message queue is larger than the size of the input message buffer. Note: The input message buffer is used as I/O area when NIIGSEG retrieves the message from IMS/TM. Module(s): NIIGSEG |
Actn. | Check whether the length of the received segment is as expected. AND/OR Increase the size of the input message buffer. |
Text | The GN call failed with status code :1:. |
Expl. | The failed GN call was used to retrieve the next message segment from the IMS/TM message queue. Module(s): CMGETSEG, CMSEGO, NIIGSEG |
Actn. | Contact your system programmer. |
Text | Message segment received too large for message area. |
Expl. | The length of the message segment retrieved from the IMS/TM message queue is larger than length of the message area provided by your program. Module(s): CMGETSEG, CMGSEGO, NIIGSEG |
Actn. | Increase the message area size used in your program. |
Text | The PURG call failed with status code :1:. |
Expl. | The failed PURG call was used to explicitely terminate the current message sent to the destination set in the first alternate TP PCB. Module(s): NIIPURG |
Actn. | Contact your system programmer. |
Text | Area specified (whole or part) not in input message buffer. |
Expl. | The area beginning at the specified offset in the specified length must reside entirely inside the input message buffer. Module(s): NIIRETRM |
Actn. | Correct offset and/or length used in your program. |
Text | Service module must not be called in online environment. |
Expl. | In an online environment only the Natural INPUT statement may retrieve messages from IMS/TM. Module(s): CMGETMSG, CMGETSEG, CMSEGO, NIIGMSG, NIIGSEG |
Actn. | Correct the program. |
Text | Service module must not be called in online environment. |
Expl. | In an online environment only the Natural INPUT and WRITE statements may send messages to IMS/TM using the IOPCB. Module(s): CMPUTMSG, NIIPMSG |
Actn. | Correct the program. |
Text | You tried to overwrite the NATURAL-reserved SPA area. |
Expl. | The area beginning at the specified offset in the specified length must reside entirely outside the the NATURAL-reserved SPA area. Module(s): CMPUTSPA, NIIPSPA |
Actn. | Correct the offset and/or length used in your program. |
Text | Wrong protocol type, or protocol not supported. |
Expl. | Request Document needs the type of the used document as first
part of the requested URL at operand 1. Either no protocol type or a protocol type that is not supported was specified with operand1. |
Actn. | Change the protocol type to a valid type, e.g. "http://", and run the program again. |