Com-plete has checked to establish if it is running authorised and has
discovered that it is not authorised.
System action:
Com-plete initialisation is aborted.
System programmer info:
Com-plete must run authorised. Refer to the Com-plete Installation Manual
for more details.
ZOS0002
Dataset '$1' not RECFM=U
Explanation:
Com-plete has opened the dataset $1 which it expects to have a record
format of undefined (RECFM=U). The dataset does not have this record
format.
System action:
Com-plete initialisation is aborted.
System programmer info:
This will be issued in relation to the COMPLIB dataset concatenations.
As these must be load libraries, the datasets they point at must have
RECFM=U.
ZOS0003
LINK to program $1 failed Abend Code X'$2'
Explanation:
During initialisation, Com-plete issues MVS 'LINK's to other programs. In
this case the link to program $1 has abended with abend code $2.
System action:
Com-plete initialisation processing will continue if possible.
System programmer info:
Determine why the abend occurred using the abend code and correct the
situation.
ZOS0004
DDNAME '$1' not found
Explanation:
During initialisation processing, Com-plete attempts to open the COMPLIB
dataset. In this case, the DD $1 has not been found in the Com-plete JCL.
System action:
If it is COMPLIB, Com-plete initialisation is aborted.
System programmer info:
The COMPLIB DD statement at the very least must be specified in the
Com-plete JCL.
ZOS0005
Unable to open '$1' dataset
Explanation:
Com-plete has attempted to open the $1 datasets, however, the open has
failed.
System action:
If $1 is COMPLIB, then Com-plete initialisation is aborted.
System programmer info:
The operating system will normally issue messages related to this
problem. These should help to determine and correct the problem.
ZOS0006
Permanent I/O error on 'COMPLIB' dataset
Explanation:
Self-explanatory message.
ZOS0007
ESTAE failure RC '$1'
Explanation:
During initialisation, Com-plete attempts to establish an ESTAE recovery
environment for the main task. This indicates that the ESTAE request failed
with return code $1.
System action:
Com-plete initialisation is aborted.
System programmer info:
The return code from the ESTAE should describe why the request to set
an ESTAE failed. Correct this error and retry.
ZOS0009
$1 failed for UCB $2 code x'$3'
Explanation:
Com-plete attempted to allocate or deallocate (as per $1) the UCB
identified by $2, however, the operation failed. $1 contains the error and
information codes returned from OS DYNALLOC processing.
System programmer info:
Identify the cause of the failure as per the DYNALLOC error codes.
This should generally only fail if the device is already allocated or the
device is not eligible to be allocated. If the error falls out of one of the
above catagories, contact your local support representative.