ZA60001 | ZA60002 | ZA60003 | ZA60004 | ZA60005 | ZA60010 | ZA60011
ZA60001 | Com-plete is active |
Explanation: |
This message is associated with the teletype support of Com-plete . It indicates that communications have been established with the Com-plete system after successfully dialing in with a dialup terminal. |
System action: |
This message is informational only; processing continues normally. |
Terminal operator info: |
The Com-plete system is now available for communication. |
System programmer info: |
This message is generated by module TLAMTTY and exists in TTY character code. |
ZA60002 | Data check - please reenter |
Explanation: |
This message is associated with the teletype support of Com-plete . It indicates that an input data check or parity error has occurred. |
System action: |
This message is informational only. Processing continues normally. |
Terminal operator info: |
Reenter the input. If the error persists, consult the Com-plete system programmer. |
System programmer info: |
If this message persists, check to ensure that the terminal and line devices are functioning properly. Verify that the terminal parity settings match the value specified for the PARITY= parameter of the LGCB macro statement in TIBTAB for the line in question. |
ZA60003 | Input data too long - please reenter |
Explanation: |
This message is associated with the teletype support of Com-plete . It indicates that too many characters have been entered. The maximum number of characters that may be entered is controlled by the Com-plete system programmer. |
System action: |
This message is informational only. Processing continues normally. |
Terminal operator info: |
Reenter the input. Note that backspace characters count as entered characters. If the error persists, consult the Com-plete system programmer. |
System programmer info: |
The maximum number of input characters is controlled by the BUFFER= parameter of the LGCB macro in TIBTAB for the line in question. For more information, refer to the Com-plete System Programmer's Manual. |
ZA60004 | Timeout - please reenter |
Explanation: |
This message is associated with the teletype support of Com-plete . It indicates that too much time has been taken to enter data. The normal limit is 23 seconds between each character. |
System action: |
This message is informational only. Processing continues normally. |
Terminal operator info: |
Reenter the input and decrease the amount of pause time between entries. |
System programmer info: |
The timeout value is affected by the terminal control unit either hardware or software (e.g., 3705 EP), and by specification of OPT=READ with the LGCB macro in TIBTAB. OPT=INHIBIT, which is the default, will inhibit timeouts. |
ZA60005 | Tib $1 ignored due to 9 successive errors |
Explanation: |
This message is associated with the teletype support of Com-plete . It is issued when Com-plete detects that all I/O to a specific TTY device has failed nine successive times. The specific nature of the I/O failures is listed individually when each failure occurs as separate ZA6 messages. |
System action: |
Com-plete considers the device to be permanently inoperative. A 'DISABLE' is written to the device and processing is discontinued (as though an IGN command had been received from the computer operator). |
Computer operator info: |
When the device becomes operational again, reactivate it using the RES command. |
ZA60010 | CCWOP=$1 LID=$2 SENSE=$3 CSW=$4 TTY line or model error |
Explanation: |
This message is associated with the teletype support of Com-plete . It indicates that an apparent line or modem error has occurred. |
System action: |
This message is informational only; processing continues normally. |
System programmer info: |
The data in the message indicates the nature of the problem. The fields are defined as follows:
|
Computer operator info: |
Ignore the message and restart the line. If the problem persists, notify the Com-plete system programmer of the problem. |
ZA60011 | CCWOP=$1 LID=$2 SENSE=$3 CSW=$4 TTY unusual error |
Explanation: |
This message is associated with the teletype support of Com-plete . It indicates that an unknown type of error has occurred. |
System action: |
This message is informational only; processing continues normally. |
System programmer info: |
The data in the message indicates the nature of the problem. The fields are defined as follows:
|
Computer operator info: |
Ignore the message and restart the line. If the problem persists, notify the Com-plete system programmer of the problem. |