This message is associated with the teletype support of Com-plete . It
indicates that communications have been established with the Com-plete system
after successfully dialing in with a dialup terminal.
System action:
This message is informational only; processing continues normally.
Terminal operator info:
The Com-plete system is now available for communication.
System programmer info:
This message is generated by module TLAMTTY and exists in TTY
character code.
ZA60002
Data check - please reenter
Explanation:
This message is associated with the teletype support of Com-plete . It
indicates that an input data check or parity error has occurred.
System action:
This message is informational only. Processing continues normally.
Terminal operator info:
Reenter the input. If the error persists, consult the Com-plete system
programmer.
System programmer info:
If this message persists, check to ensure that the terminal and line
devices are functioning properly. Verify that the terminal parity settings
match the value specified for the PARITY= parameter of the LGCB macro statement
in TIBTAB for the line in question.
ZA60003
Input data too long - please reenter
Explanation:
This message is associated with the teletype support of Com-plete . It
indicates that too many characters have been entered. The maximum number of
characters that may be entered is controlled by the Com-plete system
programmer.
System action:
This message is informational only. Processing continues normally.
Terminal operator info:
Reenter the input. Note that backspace characters count as entered
characters. If the error persists, consult the Com-plete system programmer.
System programmer info:
The maximum number of input characters is controlled by the BUFFER=
parameter of the LGCB macro in TIBTAB for the line in question. For more
information, refer to the Com-plete System Programmer's Manual.
ZA60004
Timeout - please reenter
Explanation:
This message is associated with the teletype support of Com-plete . It
indicates that too much time has been taken to enter data. The normal limit is
23 seconds between each character.
System action:
This message is informational only. Processing continues normally.
Terminal operator info:
Reenter the input and decrease the amount of pause time between
entries.
System programmer info:
The timeout value is affected by the terminal control unit either
hardware or software (e.g., 3705 EP), and by specification of OPT=READ with the
LGCB macro in TIBTAB. OPT=INHIBIT, which is the default, will inhibit
timeouts.
ZA60005
Tib $1 ignored due to 9 successive errors
Explanation:
This message is associated with the teletype support of Com-plete . It
is issued when Com-plete detects that all I/O to a specific TTY device has
failed nine successive times. The specific nature of the I/O failures is listed
individually when each failure occurs as separate ZA6 messages.
System action:
Com-plete considers the device to be permanently inoperative. A
'DISABLE' is written to the device and processing is discontinued (as though an
IGN command had been received from the computer operator).
Computer operator info:
When the device becomes operational again, reactivate it using the RES
command.
ZA60010
CCWOP=$1 LID=$2 SENSE=$3 CSW=$4 TTY line or model error
Explanation:
This message is associated with the teletype support of Com-plete . It
indicates that an apparent line or modem error has occurred.
System action:
This message is informational only; processing continues normally.
System programmer info:
The data in the message indicates the nature of the problem. The
fields are defined as follows:
$1 - Channel program op code: 2F=disable, 27=enable, 01=write
02=read, 0A=inhibit
$2 - Line ID
$3 - Sense data from terminal control unit (see the appropriate
hardware manual)
$4 - Device and channel status from CSW.
Computer operator info:
Ignore the message and restart the line. If the problem persists,
notify the Com-plete system programmer of the problem.
ZA60011
CCWOP=$1 LID=$2 SENSE=$3 CSW=$4 TTY unusual error
Explanation:
This message is associated with the teletype support of Com-plete . It
indicates that an unknown type of error has occurred.
System action:
This message is informational only; processing continues normally.
System programmer info:
The data in the message indicates the nature of the problem. The
fields are defined as follows:
$1 - Channel program op code: 2F=disable, 27=enable, 01=write,
02=read, 0A=inhibit
$2 - Line ID
$3 - Sense data from terminal control unit (see the appropriate
hardware manual)
$4 - Device and channel status from CSW.
Computer operator info:
Ignore the message and restart the line. If the problem persists,
notify the Com-plete system programmer of the problem.