This document covers the following topics:
Invoke Con-nect from a user-written program and execute the specified Con-nect command sequence. The functions then available to the user can be restricted if necessary through modifying the profile via the administration function.
You must not call Z-CMD from Con-nect (if the program which calls Z-CMD is invoked from Con-nect, Z-CMD cannot be executed).
Z-CMD supports Con-nect functions which would not otherwise be available via the API subprograms. Typical use of Z-CMD would be to access the Con-nect editor from a user-written application.
Before invoking Z-CMD, you must stack the following data (in the same sequence as listed in the table):
Stack Data | Format | In | Out | Remarks |
---|---|---|---|---|
Command | A60 | R | A Con-nect command sequence. | |
Cabinet | A8 | R | The cabinet to be used. | |
Password | A8 | R | The password of the above cabinet. | |
Program-name | A8 | R | The name of a user-written program to be executed upon leaving Con-nect. | |
CNT-library | A8 | R | The name of the Con-nect library. Default: SYSCNT2. |
Note:
Since Z-CMD is a Natural program (and not a subprogram) you must not
use the CALLNAT statement to call it.
If Z-CMD is invoked from another library than the Con-nect library, you must save any global variables that are defined in the user-written program to avoid their being lost.
To return to the user-written application, you must leave Con-nect as usual (i.e. you must return to the menu which has been defined in your profile and then issue the QUIT command). You can also skip the menu (i.e. return to the application without displaying the menu). To do so, you must use a period (.) in the last byte of the Command parameter. The period must be preceded by at least one blank.
The Con-nect global area GL-STD can be modified using Con-nect online or using Z-CMD. It cannot be modified by an API subprogram. GL-STD contains the variable G-USER-DATA (A250) which is not used by Con-nect, but is available for your user-written programs.
Con-nect does not modify or check modified values in G-USER-DATA.
None
None
0010 DEFINE DATA 0020 * 0030 LOCAL 0040 1 COMMAND (A60) /* Direct command to be executed in Con-nect 0050 1 CABINET (A8) /* Cabinet to be used (usually USERID) 0060 1 PASSWORD (A8) /* Password, if necessary for cabinet 0070 1 PROGRAM-NAME (A8) /* Program to be executed after RETURN 0080 1 CNT-LIBRARY (A8) /* Name of the Con-nect library 0090 /* Default: 'SYSCNT2' 0100 END DEFINE 0110 / *********************************************** 0120 * 0130 * Coding of the application program 0140 * 0150 ************************************************* 0160 * 0170 MOVE 'MOD DOC DOC-NAME' TO COMMAND 0180 MOVE 'USER-ID' TO CABINET 0190 MOVE 'PW' TO PASSWORD 0200 MOVE 'C-EXIT' TO PROGRAM-NAME 0210 RESET CNT-LIBRARY 0220 * 0230 STACK TOP DATA FORMATTED 0240 COMMAND CABINET PASSWORD PROGRAM-NAME CNT-LIBRARY 0250 * 0260 STACK TOP COMMAND 0270 'Z-CMD' 0280 END