Monitor Injection Order
To support the Apama Connectivity with Device Integration Platform, you must inject the following monitor files into the correlator before injecting your application monitors:
connectivity/monitors/DIP_EventDefinitions.mon connectivity/monitors/DIP_ServiceMonitor.mon As with other Connectivity plugins, the application should call com.softwareag.connectivity.ConnectivityPlugins.onApplicationInitialized() once it is injected. Use samples/DeviceIntegrationPlatform/monitors/AppReady.mon in installation as a reference.