ERROR-121 | ERROR-122 | ERROR-123 | ERROR-124 | ERROR-125 | ERROR-126 | ERROR-127 | ERROR-128 | ERROR-129 | ERROR-130 | ERROR-131 | ERROR-132 | ERROR-133 | ERROR-134| ERROR-121 | Invalid descriptor field list for invert | 
| Explanation | 
                            The field name "xx" is either 
  | 
                     
| Action | 
                            Supply the correct parameter value and rerun the job.  | 
                     
| ERROR-122 | TEMP data set too small; input record count = count | 
| Action | 
                            Supply a larger TEMP data set/file. See the Adabas Utilities documentation for information about calculating TEMP space.  | 
                     
| ERROR-123 | Invalid or missing couple descriptor | 
| Explanation | 
                            One of the supplied descriptor names 
  | 
                     
| Action | 
                            Supply the correct parameter value and rerun the job.  | 
                     
| ERROR-124 | Couple index overflow for file file-number | 
| Explanation | 
                            This file is already coupled to 18 others; this is the maximum.  | 
                     
| ERROR-125 | Files already coupled | 
| Explanation | 
                            Utility function cannot be processed.  | 
                     
| ERROR-126 | Coupling not possible | 
| Explanation | 
                            This error occurred because 
 The ADAINV function cannot be processed.  | 
                     
| ERROR-127 | Missing utility function | 
| Explanation | 
                            INVERT or COUPLE must be entered, then rerun ADAINV.  | 
                     
| ERROR-128 | Invalid value for the parameter 'CODE' | 
| Explanation | 
                            The value specified for the CODE parameter is either incorrect, or the CODE parameter is not valid in this case.  | 
                     
| Action | 
                            Either remove the CODE parameter, or specify at most eight digits, or blanks. Rerun the job. Refer to the Adabas Security documentation for more information.  | 
                     
| ERROR-129 | An attempt was made to create a 16TH index level | 
| Explanation | 
                            No more than 15 index levels are possible.  | 
                     
| Action | 
                            Try this function again with a smaller value for ASSOPFAC.  | 
                     
| ERROR-130 | Error initializing collating user exit - return code=return-code | 
| Explanation | 
                            An error occurred while the collation descriptor user exit was being initialized.  | 
                     
| Action | 
                            Investigate the cause of the error; correct it; and rerun the job.  | 
                     
| ERROR-131 | Collating user exit not loaded | 
| Explanation | 
                            The collation descriptor user exit requested is not loaded.  | 
                     
| Action | 
                            Load the exit and rerun the job.  | 
                     
| ERROR-132 | Couple index not allocated for file file The FCB does not have available space for a couple index.  | 
                     
| Explanation | 
                            ADAINV detected that there is not enough room in the FCB to allocate couple information.  | 
                     
| Action | 
                            Correct the error and rerun the job.  | 
                     
| ERROR-133 | Invalid file requested (file number = nnn) | 
| Explanation | 
                            The ADAINV INVERT and ADAINV COUPLE functions cannot be performed on a LOB file; it is not allowed.  | 
                     
| Action | 
                            Supply correct file numbers for the FILES parameter and rerun the job.  | 
                     
| ERROR-134 | The database is active but the utility communications block (DIB) is missing the nucleus entry | 
| Explanation | 
                            The ADAINV utility determined the nucleus was active without a DIB entry.  | 
                     
| Action | 
                            Check the job to ensure the correct ASSO, DATA, and WORK data sets are specified for the given DBID.  |