NETE001I: | NETE002E: | NETE003E: | NETE004E: | NETE005E:
NETE001I: | IBM zEDC compression services interface active |
Explanation |
Initialization of IBM’s system zEnterprise Data Compression (zEDC) services was successful. |
Action |
No action is required for this informational message. |
NETE002E: | IBM zEDC compression services interface failed |
Explanation |
Initialization of IBM’s System zEnterprise Data Compression (zEDC) services failed. Entire Net-Work was unable to load one or more zEDC support modules. |
Action |
Verify that the required zEDC modules are available for Entire Net-Work to load. If compression is not required, set the ZEDC LINK parameter to N. |
NETE003E: | Cannot active zEDC compression services. LPAR Capabilities down level |
Explanation |
Entire Net-Work's invocation of IBM's zEnterprise Data Compression (zEDC) services "FPZARZV" indicated that the LPAR does not support zEDC compression. |
Action |
Contact your IBM support specialist if you want to use zEDC. |
NETE004E: | Unable to LOAD IBM Compression Support Modules, Reason Code=nnnnnnnn |
Explanation |
The Entire Net-Work module "Netzedc" was unable to load IBM's zEnterprise Data Compression (zEDC) services "FPZ4*". |
Action |
Verify that Entire Net-Work has access to the IBM’s zEDC support modules FPZ4RZV,FPZ4PRB, FPZ4RMR, FPZ4DMR, FPZ4ABC and FPZ4URZ. If the problem persists, contact your Software AG technical support representative. |
NETE005E: | Attempting to initialize previously initialized zEDC support interface |
Explanation |
The Entire Net-Work module "Netzedc" detected a second zEDC initialization call. Only one initialization invocation is allowed. |
Action |
Contact your Software AG technical support representative for assistance. |