TCP/IP Code/State  | Message Text  | Recommended Action  | 
10004 (WSAEINTR)  | Interrupted function call: a blocking operation was interrupted.  | None required.  | 
10013 (WSAEACCES)  | Permission denied: Socket access attempt is prohibited by its access permissions.  | Notify network administrator.  | 
10014 (WSAEFAULT)  | Bad pointer address detected in a socket function call pointer argument.  | Contact a Software AG technical representative.  | 
10022 (WSAEINVAL)  | Winsock function called with an invalid argument.  | Contact a Software AG technical representative.  | 
10024 (WSAEMFILE)  | No file descriptors are available: too many open sockets.  | Close some connections and retry the connect; notify CONNX Technical Support if problem recurs.  | 
10035 (WSAEWOULDBLOCK)  | The requested operation would block a non-blocking socket.  | Retry the operation.  | 
10036 (WSAEINPROGRESS)  | Blocking sockets operation in progress.  | Retry the operation.  | 
10037 (WSAEALREADY)  | Operation already in progress. A second operation was attempted on a nonblocking socket.  | Contact a Software AG technical representative.  | 
10038 (WSAENOTSOCK)  | Socket operation on non-socket.  | Contact a Software AG technical representative.  | 
10039 (WSAEDESTADDRREQ)  | Destination address required.  | Double-check the TCP/IP destination address and port number; notify CONNX Technical Support if problem recurs.  | 
10040 (WSAEMSGSIZE)  | Message too long.  | Contact a Software AG technical representative.  | 
10041 (WSAEPROTOTYPE)  | Protocol wrong type for socket.  | Contact a Software AG technical representative.  | 
10042 (WSAENOPROTOOPT)  | Unknown / unsuppported winsock option.  | Contact a Software AG technical representative.  | 
10043 (WSAEPROTONOSUPPORT)  | Protocol not supported.  | Probable configuration error; notify network administrator.  | 
10044 (WSAESOCKTNOSUPPORT)  | Socket type not supported.  | Notify network administrator and CONNX Technical Support.  | 
10045 (WSAEOPNOTSUPP)  | Operation not supported.  | Contact a Software AG technical representative.  | 
10046 (WSAEPFNOSUPPORT)  | Protocol family not supported.  | Notify network administrator.  | 
10047 (WSAEAFNOSUPPORT)  | Address family not supported by protocol family.  | Contact a Software AG technical representative.  | 
10048 (WSAEADDRINUSE)  | Requested address is in use. Only one usage of each socket address (protocol/IP address/port) is permitted.  | Notify network and DB2 administrators.  | 
10049 (WSAEADDRNOTAVAIL)  | Cannot assign requested address.  | Double-check TCP/IP destination address and port number; retry.  | 
10050 (WSAENETDOWN)  | Network subsystem failed.  | Notify network administrator.  | 
10051 (WSAENETUNREACH)  | The requested network is currently unreachable.  | Retry connect attempt later; also try pinging the destination address.  | 
10052 (WSAENETRESET)  | Remote host has reset the connection.  | Retry connection; notify CONNX Technical Support if problem recurs.  | 
10053 (WSAECONNABORTED)  | Network dropped the connection because of a timeout or related failure.  | Contact a Software AG technical representative.  | 
10054 (WSAECONNRESET)  | Connection was reset by the partner.  | Retry connection; notify network and DB2 administrators if problem persists.  | 
10055 (WSAENOBUFS)  | No buffer space available: too many connections.  | Close some client applications and try again; notify CONNX Technical Support if problem persists.  | 
10056 (WSAEISCONN)  | Socket is already connected.  | Contact a Software AG technical representative.  | 
10057 (WSAENOTCONN)  | Socket is not connected.  | Contact a Software AG technical representative.  | 
10058 (WSAESHUTDOWN)  | Cannot send after socket shutdown.  | Contact a Software AG technical representative.  | 
10060 (WSAETIMEDOUT)  | The connect request timed out.  | Verify that TCP/IP is supported and started on the target server, and that the IP address and port are correct.  | 
10061 (WSAECONNREFUSED)  | Connection refused.  | Verify that TCP/IP is supported and started on the target server, and that the IP address and port are correct.  | 
10064 (WSAEHOSTDOWN)  | Host is down: socket operation failed.  | Retry connection; notify network and DB2 administrators if problem persists.  | 
10065 (WSAEHOSTUNREACH)  | Requested network is currently unreachable from this host.  | Retry connect attempt later; also try pinging the destination address.  | 
10067 (WSAEPROCLIM)  | Too many processes. The maximum number of simultaneous applications using a socket has been reached.  | Close some client connections and retry; notify CONNX Technical Support if problem persists.  | 
10091 (WSASYSNOTREADY)  | Network subsystem is not ready for communication.  | Probable client configuration problem; notify network administrator.  | 
10092 (WSAVERNOTSUPPORTED)  | The requested Windows Sockets version is not supported by the winsock DLL.  | Probable client configuration problem; notify network administrator.  | 
10093 (WSANOTINITIALISED)  | Successful WSAStartup not yet performed.  | Contact a Software AG technical representative.  | 
10094 (WSAEDISCON)  | Graceful shutdown in progress.  | Retry connection.  | 
11001 (WSAHOST_NOT_FOUND)  | Host not found.  | Double-check the TCP/IP address and the port number of the target server.  | 
11002 (WSATRY_AGAIN)  | Host not found; try again. The name server did not return the hostname IP address.  | Retry the connection.  | 
11003 (WSANO_RECOVERY)  | A non-recoverable error occurred during a database lookup. One or more HOSTS, SERVICES, or PROTOCOLS files could not be found, or a DNS server returned a severe error.  | Probable client configuration problem; notify network administrator.  | 
11004 (WSANO_DATA)  | Valid name, no data record of requested type. The hostname is not defined at the name server, or in the hosts file.  | Probable network configuration problem; notify network administrator.  |