NETT* - Translation Routine Messages

NETTnnn messages are specific messages coming from the translation routines.

Overview of Messages

NETT001 | NETT002 | NETT003 | NETT004 | NETT005 | NETT006 | NETT007 | NETT008 | NETT010 | NETT011 | NETT012 | NETT013 | NETT014 | NETT015 | NETT016 | NETT017 | NETT018 | NETT019 | NETT021 | NETT024 | NETT025 | NETT026 | NETT027 | NETT028

NETT001 INPUT BUFFER TRANSLATION ERROR; RESULT RSP=229
Explanation

An error has been detected in the application's FB (Format buffer) or SB (Search Buffer). All the buffers are snapped to help assist in the application debugging.

Forces an RSP=229 to be returned to the application.

Action

Verify that the application s format and/or search buffer is specified in valid syntax.


NETT002 ENTIRE BUFFER NOT TRANSLATED
Explanation

An error has been detected in user buffer translation. The length specified for a buffer is less than the actual length returned by Adabas.

Translation for this request is terminated.

Action

Verify that each field specified in the format buffer has a related format and length.


NETT003 DBID dbid AVAILABLE ON NODE nodeid
Explanation

A connection to an RDA message-based remote node has been established. The messages displays a list of targets available on the node.

Action

No action is required. This message is informational only.


NETT004 message-identifier ADMIN MSG FROM NODE nodeid RECEIVED
Explanation

An administration message has been received from an RDA message-based remote node.

Action

No action is required. This message is informational only.


NETT005 INCOMING ADMIN MSG NOT A REQUEST
Explanation

An administration message has been received from an RDA message-based remote node but the request indicator has not been set.

The incoming message is ignored and processing continues.

Action

Contact your Software AG technical support representative.


NETT006 UNKNOWN OUTPUT MESSAGE
Explanation

It has been determined that a message that is to be sent cannot be properly translated.

The message is neither translated nor sent, and processing continues.

Action

Contact your Software AG technical support representative.


NETT007 UNKNOWN INPUT MESSAGE
Explanation

It has been determined that a message that has been received cannot be properly translated.

The message is ignored, and processing continues.

Action

Contact your Software AG technical support representative.


NETT008 COMPRESSED MESSAGE NOT SUPPORTED
Explanation

A message to be sent to a remote VMS, UNIX, or OS/2 node is in compressed format.

The outgoing message is ignored.

Action

Make sure that the compression option is not turned on for any other links within the network task.


NETT010 REPLY DISCARDED ON LINK xxxxxxxx
Explanation

The link was reconnected after a request was received from the link, but before the reply was received from the target and sent back across the link.

The message is discarded.

Action

No action is required. This message is informational only.


NETT011 nnnnn OUTSTANDING REQUESTS FREED ON LINK xxxxxxxx
Explanation

nnnnn messages were discarded as a result of the link being disconnected.

Messages were discarded.

Action

No action is required.


NETT012 SHORT TERM BUFFER SHORTAGE/ERRORS
Explanation

A failure occurred trying to obtain or release Entire Net-Work short-term buffers.

The link is marked "suspended".

Action

Increase the short-term buffer allocation.


NETT013 TRANSLATION DEFINITION ADDED SUCCESSFULLY
Explanation

A translation add request was issued to Entire Net-Work and was successfully added to the active translation table.

Action

No action is required. This message is informational only.


NETT014 TRANSLATION DEFINITION DELETED SUCCESSFULLY
Explanation

A translation delete/remove request was issued to Entire Net-Work and a translation definition with matching criteria was successfully removed from the active translation table.

Action

No action is required. This message is informational only.


NETT015 TRANSLATION DEFINITION DELETE FAILED
Explanation

A translation delete/remove request was issued to Entire Net-Work and no translation definition with matching criteria could be located in the active translation table.

Action

Check the translation delete/remove request for correctness.


NETT016 DBID FILE FIELD ATOE ETOA EXIT FORMAT

NETT017 output from the translat display list operator command

NETT018 TRANSLATION DISPLAY COMPLETE
Explanation

This group of messages is issued for each TRANSLAT DISPLAY LIST command issued to Entire Net-Work. Message NETT017 will be issued for each active translation definition.

Action

No action is required. This message is informational only.


NETT019 TRANSLATION DEFINITION ALREADY EXISTS - IGNORED
Explanation

A TRANSLAT DEFINE ADD request was issued to Entire Net-Work and was not added to the active translation table due to an active translation definition already existing for the specified database ID, file ID and field ID.

Action

Check the translation define/add request for correctness. If correct, a duplicate already exists. Otherwise, correct the request and try again.


NETT021 CONVERTER LOGGING DATA
Explanation

If logging is turned on (LOGGING=Y), this DDPRINT message precedes the actual logging data.

Action

No action is required. This message is informational only.


NETT024 CONNECTION REJECTED DUE TO INVALID NODE ID FROM NODE xxxxxxxx
Explanation

A UNIX or OpenVMS Entire Net-Work node tried to connect with node ID = 0.

Action

Specify a node ID in the configuration file on the UNIX or OpenVMS node.


NETT025 TEXT MESSAGE RECEIVED ON LINK linkname
Explanation

A text message from an Entire Net-Work workstation node has been received on the identified link. The message is displayed immediately following the NETT025 message.

Action

See the Entire Net-Work 7 User's Guide or the Entire Net-Work 7 online documentation for a description of the message received from the workstation node.


NETT026 SERVER MESSAGE DISCARDED FROM CLIENT ONLY LINK xxxxxxxx
Explanation

A server broadcast message was received from a partner Entire Net-Work node with a node ID of 0. The message is ignored and the servers listed in the message are inaccessible.

Action

If the servers on the partner machine need to be accessible from the mainframe, a node ID must be specified in the configuration file of the partner node.


NETT027 NODE MESSAGE DISCARDED FROM CLIENT ONLY LINK
Explanation

A node message was received from a partner Entire Net-Work node with a node ID of 0. The message is ignored.

Action

No action is required for this informational message.


NETT028 Entire Net-Work V5 IGNORES SERVERS ON NODES WITH A NODE ID OF 0
Explanation

A server broadcast message was received from a partner Entire Net-Work node with a node ID of 0. The servers on the partner node are ignored.

This message is sent to the partner node as an informational message.

Action

No action is required for this informational messsage.