ART* - Event Replicator Target Adapter Messages

Overview of Messages

ART0102I | ART0103E | ART0104I | ART0105I | ART0106I | ART0107I | ART0108E | ART0109E | ART0110E | ART0111E | ART0112I | ART0113I | ART0114I | ART0115E | ART0116I | ART0117I | ART0118I | ART0119E | ART0120E | ART0121E | ART0122I | ART0123E | ART0124I | ART0125I | ART0303I | ART0304I | ART0305I | ART0307I | ART0308I | ART0309I | ART0310I | ART0311I | ART0314I | ART0315I | ART0316I | ART0317I | ART0318I | ART0319I | ART0320E | ART0321E | ART0322E | ART0323I | ART0324E | ART0325I | ART0401I | ART0402I | ART0403I | ART0404I | ART0405I | ART0406I | ART0407I | ART0408I | ART0409I | ART0410I | ART0411I | ART0412I | ART0501I | ART0502I | ART0503I | ART0504I | ART0505I | ART0506I | ART0507E | ART0508E | ART0509E | ART0510E | ART0511E | ART0512E | ART0513E | ART0514E | ART0515I | ART0516I | ART0517E | ART0518E | ART0519E | ART0520E | ART0521E | ART0601I | ART0602E | ART0603I | ART0604E | ART0605E | ART0606E | ART0607E | ART0608E | ART0609E | ART0610E | ART0611E | ART0612E | ART0613I | ART0614I | ART0615E | ART0616E | ART0617E | ART0701I | ART0702I | ART0703I | ART0704I | ART0705E | ART0706E | ART0707E | ART0708E | ART0801I | ART0802I | ART0803I | ART0901E | ART0902I | ART0903I | ART1001E | ART1002E | ART1005W | ART1007W | ART1008W | ART1009W | ART1101I | ART1102I | ART1103E | ART1104I | ART1105I | ART1106I | ART1107I | ART1108E | ART1109I | ART1201I | ART1203W | ART1204E | ART1205E | ART1206E | ART1207E | ART1208I | ART1209I | ART1210I | ART1211E | ART1212E | ART1213E | ART1214W | ART1215E | ART1216E | ART1217F | ART1218F | ART1219E | ART1220E | ART1221E | ART1222E | ART1223E | ART1224E | ART1225E | ART1226E | ART1227E | ART1228E | ART1229E | ART1230E | ART1232E | ART1233I | ART1234I | ART1235W | ART1236E | ART1237W | ART1238I | ART1239I | ART1240E | ART1241W | ART1242E | ART1243W | ART1244I | ART1245I | ART1246I | ART1302I | ART1303E | ART1304E | ART1305E | ART1307E | ART1308E | ART1309E | ART1310I | ART1311I | ART1312I | ART1313I | ART1315I | ART1316E | ART1318I | ART1319E | ART1320E | ART1321E | ART1322E | ART1323E | ART1324E | ART1325E | ART1326I | ART1327E | ART1328E | ART1329E | ART1330E | ART1331E | ART1332E | ART1333E | ART1334E | ART1335E | ART1336E | ART1337E | ART1338E | ART1339W | ART1340E | ART1341E | ART1342E | ART1343W | ART1344W | ART1401I | ART1402E | ART1501I | ART1502I | ART1503I | ART1504I | ART1601I | ART1602I | ART1603I | ART1604I | ART1701W | ART1702W | ART1703W | ART1801E | ART1802E | ART1803E | ART1804I | ART1805I | ART1806E | ART1807E | ART1808E | ART1809E | ART1810E | ART2001E | ART2002E | ART2003E | ART2004E | ART3001E | ART3002E | ART3003E | ART3004E | ART3005E | ART3006E

ART0102I An Event Replicator Target Adapter engine is started and waiting for work
Explanation

An Event Replicator Target Adapter has successfully started and is waiting for work.

Action

No action is required for this informational message.


ART0103E Unable to load resource bundle; message
Explanation

This is an internal error.

Action

Contact your Software AG technical support representative for assistance.


ART0104I Version information version
Explanation

The version of the Event Replicator Target Adapter that is running is given in the message (version).

Action

No action is required for this informational message.


ART0105I Engine shutdown requested
Explanation

A request has been made to shut down the Event Replicator Target Adapter.

Action

No action is required for this informational message.


ART0106I Main processing loop shutdown requested
Explanation

A request has been made to shut down the main processing loop of the Event Replicator Target Adapter.

Action

No action is required for this informational message.


ART0107I Operation message: input-msg
Explanation

An operation message (input-msg) is listed in the text of this message.

Action

No action is required for this informational message.


ART0108E Invalid or unprocessed message received: msg
Explanation

An invalid or unprocessed message was received. The invalid message (msg) is provided in the text of this message.

Action

Review any previous messages to determine the primary cause of the problem. If the problem persists, contact your Software AG technical support representative for assistance.


ART0109E Cannot connect to target
Explanation

An attempt to connect to a defined target failed.

Action

Evaluate the target definition to determine the cause of the problem. If you cannot determine the cause of the problem, contact your Software AG technical support representative for assistance.


ART0110E Operation status: status
Explanation

The status of the failed operation (status) is provided in the text of this message. This message accompanies other error messages. Possible statuses are "Failed" and "FailedRetry".

Action

Review the other messages that accompany this one to determine the cause of the problem. If you cannot determine the cause of the problem, contact your Software AG technical support representative for assistance.


ART0111E Incorrect message: msg
Explanation

The message in error (msg) is provided in the text of this message, which accompanies other error messages.

Action

Review the other messages that accompany this one to determine the cause of the problem. If you cannot determine the cause of the problem, contact your Software AG technical support representative for assistance.


ART0112I Database retry count is 0
Explanation

The database retry count setting has reached the value of zero (0). No further database retries are attempted and the source is closed.

Action

Restart the database and reopen the source.


ART0113I Waiting secs seconds before database retry number of total
Explanation

The Event Replicator Target Adapter is waiting the number of seconds listed in the message (secs) before attempting to reconnect to the source database. The retry attempt number (number) and the total number of retry attempts defined for the source (total) are also given in the message.

Action

No action is required for this informational message.


ART0114I Attempting database retry number of total
Explanation

The Event Replicator Target Adapter is attempting to reconnect to a source database. The retry attempt number (number) and the total number of retry attempts defined for the source (total) are given in the message.

Action

No action is required for this informational message.


ART0115E XSLT or XML document is null
Explanation

The style sheet (XSLT) or XML document to be used in Event Replicator Target Adapter processing is null or cannot be found. This is an internal error.

Action

Contact your Software AG technical support representative for assistance.


ART0116I Committing invalid or unprocessed message
Explanation

The invalid message was committed because the Commit Unprocessed Message option was set to true. Processing continues.

Action

No action is required for this informational message.


ART0117I IVP message received and processed
Explanation

The installation verification procedure (IVP) message was received and processed successfully.

Action

No action is required for this informational message.


ART0118I Received count request
Explanation

The number of requests received is listed in the message (count).

Action

No action is required for this informational message.


ART0119E Received unknown message msg
Explanation

An unknown message was received.

Action

Contact your Software AG technical support representative for assistance.


ART0120E Cannot convert input message from source code page num1 to num2
Explanation

The input message listed in the message text could not be converted from one code page (num1) to another (num2).

Action

Contact your Software AG technical support representative for assistance.


ART0121E Current messages
Explanation

This message accompanies message ARTO108E.

Action

Review all the messages to determine the cause of the problem. If the problem persists, contact your Software AG technical support representative for assistance.


ART0122I Problems writing file; directory must exist: dirname
Explanation

A file could not be written because the directory listed in the message did not exist.

Action

Create the directory and restart the Event Replicator Target Adapter.


ART0123E Unprocessed data count bytes in buffer buf
Explanation

An internal error has occurred.

Action

Contact your Software AG technical support representative for assistance.


ART0124I Successful database reconnect for target target
Explanation

An attempt to reconnect to the database target was successful.

Action

No action required for this informational message


ART0125I Software AG License check license
Explanation

A Software AG license check occurred for the license shown in the message.

Action

No action required for this informational message


ART0303I Initial-state process started for: isname
Explanation

The Event Replicator Target Adapter has started processing an initial-state request. The name of the initial-state definition (isname) is listed in the message.

Action

No action is required for this informational message.


ART0304I Initial-state process completed for: isname
Explanation

The Event Replicator Target Adapter has completed processing an initial-state request. The name of the initial-state definition (isname) is listed in the message.

Action

No action is required for this informational message.


ART0305I Initial-state erroneous request rejected
Explanation

An invalid initial-state request was rejected. It was not processed.

Action

No action is required for this informational message. However, you might want to review the invalid initial-state request to determine why it was not processed.


ART0307I Normal Event Replicator Server session started message received from: reptor-id
Explanation

A normal Event Replicator Server session has started and a message has been received from it. The Event Replicator Server ID is listed in the message (reptor-id).

Action

No action is required for this informational message.


ART0308I Event Replicator Server restart after abnormal end
Explanation

The Event Replicator Server has restarted after it ended abnormally.

Action

No action is required for this informational message although you might want to review the error messages provided by the Event Replicator Server to determine why it ended abnormally.


ART0309I Normal Event Replicator Server session termination message received from: reptor-id
Explanation

A normal Event Replicator Server session has terminated. The Event Replicator Server ID is listed in the message (reptor-id).

Action

No action is required for this informational message.


ART0310I Replication deactivated
Explanation

Replication has been deactivated (stopped).

Action

No action is required for this informational message.


ART0311I Replication reactivated
Explanation

Replication has been reactivated (started).

Action

No action is required for this informational message.


ART0314I Replay process (ADARPL) started
Explanation

The ADARPL utility has started to resend replicated data from the database protection log (PLOG) to the target RDBMS. For more information, read about the ADARPL utility in your Event Replicator for Adabas documentation.

Action

No action is required for this informational message.


ART0315I Replay process (ADARPL) ended
Explanation

The ADARPL utility has completed resending replicated data from the database protection log (PLOG) to the target RDBMS. For more information, read about the ADARPL utility in your Event Replicator for Adabas documentation.

Action

No action is required for this informational message.


ART0316I Event Replicator Server replication definitions refreshed
Explanation

The Event Replicator Server replication definitions have been refreshed via an RPLREFRESH command.

Action

No action is required for this informational message.


ART0317I ADALOD UPDATE started
Explanation

A run of the ADALOD UPDATE utility function has started.

Action

No action is required for this informational message.


ART0318I ADALOD UPDATE ended
Explanation

A run of the ADALOD UPDATE utility function has ended.

Action

No action is required for this informational message.


ART0319I ADALOD LOAD ended. Source: src Target: target
Explanation

A run of the ADALOD LOAD utility function has ended.

Action

No action is required for this informational message.


ART0320E Unknown status message message
Explanation

An unknown status message was encountered during Event Replicator Target Adapter processing. The status message is given in the message text.

Action

Contact your Software AG technical support representative for assistance.


ART0321E Unknown URBS operation operation
Explanation

An unknown URBS operation was attempted. The type of operation attempted is listed in the message text.

Action

Contact your Software AG technical support representative for assistance.


ART0322E Invalid DBID dbid or file number fn
Explanation

An invalid database ID or file number was encountered during processing.

Action

Check your GFB/GFFT definition. Contact your Software AG technical support representative for assistance.


ART0323I Receiving LODS message: Source: src Target: target
Explanation

An ADALOD message is being received. The data source and target are listed in the message.

Action

No action is required for this informational message.


ART0324E Receiving unknown message
Explanation

An unknown message was received during processing.

Action

Contact your Software AG technical support representative for assistance.


ART0325I Receiving AUT1 message (Adabas utility execution)
Explanation

An AUT1 message produced by the execution of an Adabas utility is being received.

Action

No action is required for this informational message.


ART0401I Testing database connections
Explanation

The Event Replicator Target Adapter is testing its database connections.

Action

No action is required for this informational message.


ART0402I Database information at startup:
Explanation

This message is the introductory message for a series of other informational messages about the databases to which the Event Replicator Target Adapter has connections.

Action

No action is required for this informational message.


ART0403I Connector protocol: protocol-type port: port
Explanation

This message lists the protocol type and port number used by the Event Replicator Target Adapter Tomcat engine.

Action

No action is required for this informational message.


ART0404I Using connector port: conn-port port: port
Explanation

This message lists the default HTTP port number that will be used.

Action

No action is required for this informational message.


ART0405I Adabas Replicator servlet shutdown started
Explanation

The Event Replicator Server is shutting down.

Action

No action is required for this informational message.


ART0406I Adabas Replicator servlet shutdown complete
Explanation

The Event Replicator Server shutdown is complete.

Action

No action is required for this informational message.


ART0407I Testing connection to database resource id
Explanation

A test is being performed that connects to the database resource listed in the message (id).

Action

No action is required for this informational message.


ART0408I Database testing complete
Explanation

Tests on the database have completed.

Action

No action is required for this informational message.


ART0409I JMS information at startup:
Explanation

This message is the introductory message for a series of other informational messages about the JMS to which the Event Replicator Target Adapter has connections.

Action

No action is required for this informational message.


ART0410I JMS testing complete
Explanation

Tests on the JMS have completed.

Action

No action is required for this informational message.


ART0411I Generic Target information at startup:
Explanation

This message is the introductory message for a series of other informational messages about feneric targets to which the Event Replicator Target Adapter has connections (for example, a Terracotta cache target).

Action

No action is required for this informational message.


ART0412I Generic Target testing complete
Explanation

Tests on the generic targets have completed.

Action

No action is required for this informational message.


ART0501I EntireX Broker information info
Explanation

This message displays information about a webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter.

Action

No action is required for this informational message.


ART0502I EntireX Broker source shutdown requested
Explanation

A request is being processed to close a webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter.

Action

No action is required for this informational message.


ART0503I EntireX Broker source shutdown requested; processing: state userstop: xxxx
Explanation

A webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter is being closed. The current state of the source is displayed in the message.

Action

No action is required for this informational message.


ART0504I EntireX Broker source close complete
Explanation

A webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter has been closed.

Action

No action is required for this informational message.


ART0505I EntireX Broker UOW rolled back ID: id
Explanation

The webMethods EntireX unit of work ID was rolled back. This is an internal process.

Action

No action is required for this informational message.


ART0506I EntireX Broker prefetch size reached: size
Explanation

The defined prefetch size for the webMethods EntireX source has been reached. The defined prefetch size is given in the message (size).

Action

No action is required for this informational message. However, you might consider increasing the defined prefetch size. Note that increasing the prefetch size will increase the memory requirements.


ART0507E EntireX Broker send error class: class code: code message: msg
Explanation

An error has occurred during an attempt to send data to a webMethods EntireX source. The error class (class), message code (code) and message text (msg) are given in the message.

Action

Refer to your webMethods EntireX documentation for additional information.


ART0508E EntireX Broker error class: class code: code message: msg
Explanation

An error has occurred during an attempt to use a webMethods EntireX source. The error class (class), message code (code) and message text (msg) are given in the message.

Action

Refer to your webMethods EntireX documentation for additional information.


ART0509E EntireX Broker exception: info
Explanation

An exception occurred during an attempt to use a webMethods EntireX source. The exception information (info) is given in the message.

Action

Contact your Software AG technical support representative for assistance.


ART0510E EntireX Broker receive error class: class code: code message: msg
Explanation

An error has occurred during an attempt to receive data from an webMethods EntireX source. The error class (class), message code (code) and message text (msg) are given in the message.

Action

Refer to your webMethods EntireX documentation for additional information.


ART0511E EntireX Broker logon error ID: class service: service message: msgtxt
Explanation

An error has occurred during an attempt to log into an webMethods EntireX source. The error class (class), service name (service), and message code (msgtxt) are given in the message.

Action

Verify that the correct logon information (user ID, token, and password) is provided in the webMethods EntireX source definition. Correct it as necessary and try again.


ART0512E EntireX Broker error on: id cause: exx-cause
Explanation

An error occurred during an attempt to use the webMethods EntireX source whose ID is listed in the message (id). The cause of the error is also listed in the message (exx-cause).

Action

Contact your Software AG technical support representative for assistance.


ART0513E EntireX Broker commit error message: err-msg
Explanation

An error occurred during an attempt to use a webMethods EntireX source definition. The webMethods EntireX error message (err-msg) is listed in the message.

Action

Contact your Software AG technical support representative for assistance.


ART0514E EntireX Broker cannot open Broker trace log file: fn
Explanation

An error occurred during an attempt to open the webMethods EntireX trace log file. The file name of the log file is given in the message (fn).

Action

Verify that the correct file name is specified for the webMethods EntireX trace log file in the webMethods EntireX definitions. If it is not, correct the name and try again. If the problem persists, contact your Software AG support representative for assistance.


ART0515I EntireX Broker trace level: lvl trace file: fn
Explanation

This message identifies the trace level (lvl) and file name (fn) used by the Event Replicator Target Adapter for webMethods EntireX sources.

Action

No action is required for this informational message.


ART0516I EntireX Broker receive complete: time: count Ms length: length UowStatus: status
Explanation

A webMethods EntireX source received data from replication. The length of time (in microseconds) for the receive operation (count), the length of the data received (length), and the unit of work status of the receive operation (status) are given in the message. Values for the unit of work status are "First", "Middle" or "Last".

Action

No action is required for this informational message.


ART0517E EntireX Broker commit error class: class code: code uowid: uowid message: msg
Explanation

An error occurred during a commit attempt for the webMethods EntireX source. The error class (class), EntireX message code (code), EntireX UOWID (uowid) and EntireX message text (msg) are listed in the message.

Action

Contact your Software AG technical support representative for assistance.


ART0518E EntireX Broker rollback error class: class code: code message: msg
Explanation

An error occurred during a rollback attempt for the webMethods EntireX source. The error class (class), EntireX message code (code) and EntireX message text (msg) are listed in the message.

Action

Contact your Software AG technical support representative for assistance.


ART0519E EntireX Broker deregister error host: host-id service: service message: msg
Explanation

An error occurred during an attempt to deregister a webMethods EntireX source. The EntireX ID (host-id), service (service) and message text (msg) are listed in the message.

Action

Contact your Software AG technical support representative for assistance.


ART0520E EntireX Broker user ID required
Explanation

A valid webMethods EntireX user ID is required but was not supplied.

Action

Supply a valid webMethods EntireX user ID and try again.


ART0521E EntireX Broker token required
Explanation

A valid webMethods EntireX token is required but was not supplied.

Action

Supply a valid webMethods EntireX token and try again.


ART0601I Save file fn with data: dddd
Explanation

An attempt to save the file listed in the message (fn) with the data listed in the message (dddd) was successful.

Action

No action is required for this informational message.


ART0602E Read resource failed for: resource-id status code: code
Explanation

An attempt to read from the resource listed in the message (resource-id) failed. The status code of the attempt is given in the message (code).

Action

Contact your Software AG technical support representative for assistance.


ART0603I Retrying resource read for: resource-id
Explanation

An attempt is being made to read from the resource listed in the message (resource-id).

Action

No action is required for this informational message.


ART0604E WebDAV error: err-code
Explanation

A WebDAV error occurred during Event Replicator Target Adapter processing.

Action

Verify that the web service target URL is correct and try again. If the problem persists, contact your Software AG technical support representative.


ART0605E WebDAV repository is not accessible err-code
Explanation

The WebDAV repository cannot be accessed.

Action

Verify that the web service target URL is correct and try again. If the problem persists, contact your Software AG technical support representative.


ART0606E Invalid WebDAV cache size value size
Explanation

An invalid WebDAV cache size has been specified. The value was not numeric.

Action

Supply a valid numeric cache size and try again.


ART0607E Cannot find generic XSLT file filename
Explanation

The XSLT file listed in the message (filename) could not be found.

Action

If the problem persists, contact your Software AG technical support representative.


ART0608E Cannot find XSLT file filename
Explanation

The XSLT file listed in the message (filename) could not be found.

Action

If the problem persists, contact your Software AG technical support representative.


ART0609E Create table XML message is null or base table name is null
Explanation

An internal error has occurred.

Action

If the problem persists, contact your Software AG technical support representative.


ART0610E Cannot convert create table schema to string
Explanation

An internal error has occurred.

Action

If the problem persists, contact your Software AG technical support representative.


ART0611E Cannot save create table schema name into WebDAV
Explanation

An attempt to save the schema named in the message (name) to the WebDAV repository failed.

Action

If the problem persists, contact your Software AG technical support representative.


ART0612E Problem with managing WebDAV file filename
Explanation

The WebDAV file named in the message (filename) could not be managed.

Action

If the problem persists, contact your Software AG technical support representative.


ART0613I Collection may not exist colname
Explanation

The collection named in the message (colname) may not exist in the WebDAV repository. The collection is created.

Action

No action is required for this informational message.


ART0614I Retrying resource write for res
Explanation

An attempt is in progress to retry the resource write for the resource named in the message (res).

Action

No action is required for this informational message.


ART0615E Write resource file fn failed err-code
Explanation

An attempt to write the resource file named in the message (fn) failed.

Action

If the problem persists, contact your Software AG technical support representative.


ART0616E WebDAV status code code status message msg
Explanation

A WebDAV internal error has occurred.

Action

If the problem persists, contact your Software AG technical support representative.


ART0617E Make collection colname failed status stat
Explanation

An attempt to make the collection named in the message (colname) failed. The status of the attempt is also given in the message (stat).

Action

If the problem persists, contact your Software AG technical support representative.


ART0701I Source shutdown complete
Explanation

An attempt to shut down a source completed successfully.

Action

No action is required for this informational message.


ART0702I Source waiting for restart after user stop or rollback
Explanation

The source is waiting to be restarted after it was manually stopped or after a rollback occurred.

Action

No action is required for this informational message. Restart the source when you are ready.


ART0703I Retries = 0; source waiting for manual restart
Explanation

The value of the Retry Count parameter in the source definition has been reached. The source is waiting for a manual restart.

Action

No action is required for this informational message. Manually restart the source when you are ready.


ART0704I Wait for retry; count: count
Explanation

The source is waiting between retry attempts. The retry attempt count is given in the message (count).

Action

No action is required for this informational message.


ART0705E No commit/rollback listener
Explanation

An internal error has occurred.

Action

Contact your Software AG technical support representative for assistance.


ART0706E Source message is null on commit
Explanation

An internal error has occurred.

Action

Contact your Software AG technical support representative for assistance.


ART0707E Unsupported source type type
Explanation

An internal error has occurred.

Action

Contact your Software AG technical support representative for assistance.


ART0708E Cannot open source capture file fn
Explanation

The file cannot be opened. Verify that the directory name exists.

Action

If the problem persists, contact your Software AG technical support representative.


ART0801I Runtime metrics
Explanation

This message is the heading message for a series of runtime metric messages.

Action

No action is required for this informational message.


ART0802I Resource key: rkey
Explanation

A resource key is listed in the message (rkey). Statistics about the resource are provided after the key.

Action

No action is required for this informational message.


ART0803I Metrics key: mkey
Explanation

A metrics key is listed in the message (mkey). Metrics about the transaction identified by the metrics key are provided after the key.

Action

No action is required for this informational message.


ART0901E Process request failed
Explanation

An Event Replicator Target Adapter process request failed. The source is shut down.

Action

Review any accompanying error messages to determine the cause of the problem. If the problem persists, contact your Software AG technical support representative.


ART0902I Database active result: result
Explanation

The result of a test to see whether the database is active or not is listed in the message (result).

Action

No action is required for this informational message.


ART0903I Retrying Database Transaction
Explanation

An attempt is in progress to retry the database transaction.

Action

No action is required for this informational message.


ART1001E Exception cause: cause
Explanation

An Event Replicator Target Adapter process request failed. The cause of the failure is given in the message (cause).

Action

Contact your Software AG technical support representative for assistance.


ART1002E Exception stack: stack
Explanation

An Event Replicator Target Adapter process request failed. The exception stack for the failure is given in the message (stack).

Action

Contact your Software AG technical support representative for assistance.


ART1005W Unable to transform document
Explanation

The Event Replicator Target Adapter was unable to transform a document.

Action

No action is required for this warning message. Determine the reason for which the Event Replicator Target Adapter cannot transform the document and alter the conditions as necessary. Then try again.


ART1007W An insert or update was received which occurred within an Initial State boundary
Explanation

An insert or update transaction message was received that falls within the boundaries of an ADARIS Initial State.

Action

This is a warning message informing of the situation described above. Followed by ART1008W or ART1009W if any action was taken with the message.


ART1008W Insert changed to Delete Before Insert for file name: file name and time stamp: time stamp; Insert is within an Initial State boundary
Explanation

Warning that a record insert was changed to delete the record (if it exists) and insert the record in the current transaction. This can occur if an insert was processed during the user-defined ADARIS Initial State time boundaries for this file. The Initial State may have already picked up the new record. Avoids a Unique Key constraint error on the target.

Action

Check that the record is in sync with the Adabas source record.


ART1009W ContinueOnSQLError dynamically turned on for file: file name and time stamp: time stamp; Update is within an Initial State boundary
Explanation

An update transaction was received that occurred during the user-defined ADARIS Initial State time boundaries for this file. The option Error Continue (ContinueOnSQLError) was dynamically turned on to avoid an SQL error on a record for which the update was already processed before the Initial State picked up the file.

Action

Check that the record is in sync with the Adabas source record.


ART1101I File source configured for input directory: dirname
Explanation

A file source definition has been configured for the input directory listed in the message (dirname).

Action

No action is required for this informational message.


ART1102I File source ready to receive data from: dirname
Explanation

A file source definition is ready to receive data from the directory listed in the message (dirname).

Action

No action is required for this informational message.


ART1103E File source unable to get list of files
Explanation

A file source could not get a list of the files from the source.

Action

Determine why a list of files could not be obtained. Resolve the error and try again. If the problem persists, contact your Software AG support representative for assistance.


ART1104I File source closing
Explanation

A file source is closing.

Action

No action is required for this informational message.


ART1105I File source returning file: FILE: dirname-->fn
Explanation

The file source definition is returning the file source as part of the file source shutdown execution. The directory (dirname) and filenamefn) are given in the message.

Action

No action is required for this informational message.


ART1106I File source shutdown requested
Explanation

Shutdown of a file source was requested.

Action

No action is required for this informational message.


ART1107I File source rollback called
Explanation

Rollback of the updates from a file source was called.

Action

No action is required for this informational message.


ART1108E File source file does not exist fn
Explanation

The file source file named in the message (fn) does not exist. This is an internal message.

Action

Contact your Software AG technical support representative for assistance.


ART1109I File source processing time for: dirname-->fn is num MilliSeconds
Explanation

The processing time is given in the message for the file identified in the message.

Action

No action is required for this informational message.


ART1201I Rollback following SQL commands
Explanation

A rollback occurred based on SQL commands.

Action

No action is required for this informational message.


ART1203W File name not provided for operation: op FNR: fnum ISN: isnnum
Explanation

A file name was not provided for the operation listed in the message (op). The file (fnum) and ISN (isnnum) numbers are also listed in the message.

Action

No action is required for this informational message.


ART1204E Test connection failed: conn-name
Explanation

A test connection to the connection listed in the message (conn-name) failed.

Action

Restart the database if it is down.


ART1205E Cannot get a connection from the data source
Explanation

An attempt to connect to a data source failed.

Action

Review the data source definition and try again. If the problem persists, contact your Software AG technical support representative for assistance.


ART1206E Cannot get metadata
Explanation

An attempt to connect to a data source failed.

Action

Review the data source definition and try again. If the problem persists, contact your Software AG technical support representative for assistance.


ART1207E Exception obtaining table metadata: tablename
Explanation

An exception occurred while the Event Replicator Target Adapter was attempting to obtain metadata from a table. The name of the table is given in the message (tblname).

Action

Contact your Software AG technical support representative for assistance.


ART1208I Process is continuing after the previous error
Explanation

Event Replicator Target Adapter processing is continuing in spite of a previously reported error condition.

Action

No action is required for this informational message.


ART1209I Unable to locate table: tablename
Explanation

The Event Replicator Target Adapter could not locate the table listed in the message (tablename).

Action

No action is required for this informational message. If you really do need the Event Replicator Target Adapter to locate this table, determine why it cannot be located and try again. If the problem persists, contact your Software AG technical support representative.


ART1210I Create index command built: cmd
Explanation

An internal command to create the index to a table was successfully built.

Action

No action is required for this informational message.


ART1211E Cannot get connection to data source name
Explanation

An attempt to connect to the data source named in the message (name) failed.

Action

Verify that the database definitions are correct and that the database is active.


ART1212E Cannot retrieve database metadata
Explanation

An attempt to retrieve metadata for the database failed.

Action

Contact your Software AG technical support representative for assistance.


ART1213E Internal error of Sybase ASE
Explanation

An internal error occurred in Sybase ASE

Action

Contact your Software AG technical support representative for assistance.


ART1214W Unknown data type type for column colname in metadata
Explanation

An attempt was made to specify the unknown data type listed in the message (type) in the column listed in the message (colname).

Action

Contact your Software AG technical support representative for assistance.


ART1215E pkTableName pkname does not match with table name tblname
Explanation

A mismatch has occurred between the table and the primary key. The table name (tblname) and the primary key (pkname) are given in the message.

Action

Contact your Software AG technical support representative for assistance.


ART1216E Cannot find previous column information
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1217F Initial context is null
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1218F Context lookup is null
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1219E Unsupported driver class name for JDBC/database dbname
Explanation

An unsupported driver class name was specified for the JDBC database listed in the message (dbname).

Action

Contact your Software AG technical support representative for assistance.


ART1220E Error obtaining connection err-code
Explanation

A connection to the database could not be made.

Action

Verify that the database definitions are correct and that the database is active.


ART1221E Table tblname has duplicate column name colname
Explanation

The table named in the message (tblname) has two columns with the same name (colname).

Action

Change one of the column names and try again.


ART1222E Cannot create statement
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1223E Cannot connect to database dbname
Explanation

An attempt to connect to the database named in the message (dbname) failed.

Action

Verify that the database definitions are correct and that the database is active.


ART1224E Cannot execute batch
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1225E Cannot turn off database autocommit
Explanation

An attempt to turn off the autocommit feature of the database failed.

Action

Contact your Software AG technical support representative for assistance.


ART1226E Cannot create executing SQL statement
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1227E Process continuing because dbErrorContinue is TRUE
Explanation

The target database Error Continue option was set to "true" (selected or turned on), so the SQL error is ignored and processing continues.

Action

No action is required for this message.


ART1228E Executing....<processing information>
Explanation

An SQL command either failed or executed successfully. The SQL command and details about its processing are given in the message (<processing information>).

If an error occurred, and you have not selected the Error Continue option for the target database, the Event Replicator Target Adapter will stop running. For more information, read Specifying Target Database Processing Option Definitions.

Action

If the command failed, resolve the error described in the message. If necessary, contact your Software AG technical support representative for assistance.


ART1229E Unable to load/construct DB support class for classname
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1230E Update to insert mode is on but full image value is missing
Explanation

An attempt to insert an update failed because the full image of the record is missing from the database.

Action

Use Option=32 in the Event Replicator Server destination definition. For more information, refer to your Event Replicator for Adabas destination documentation.


ART1232E Cannot insert column
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1233I SQL command failed cmd
Explanation

The SQL command listed in the message (cmd) failed.

Action

Review other accompanying error messages to determine the cause of the problem. If the problem persists, contact your Software AG technical support representative for assistance.


ART1234I SQL command reason rsncode
Explanation

The previous SQL command failed with the reason code (rsncode) given in the message.

Action

Review the documentation for your RDBMS to determine the cause of the problem.


ART1235W Sync DDL value val is not one of the following values, ignore, warn, apply, error. Reset to ignore.
Explanation

The value for the Adabas-RDBMS Synchronization Level option is invalid. It has been reset to "ignore".

Action

In the target database options, change the setting of the Adabas-RDBMS Synchronization Level option to something other than "ignore" if you want.


ART1236E Cannot alter column detailed-info
Explanation

The Event Replicator Target Adapter could not alter the column described by the detailed information listed in the message (detailed-info) during it's attempt to synchronize the RDBMS table with the Adabas file.

Action

Make sure the target database supports this kind of type conversion and that this column is not a primary key and doesn’t have foreign key. If the problem persists, contact your Software AG technical support representative for assistance.


ART1237W Data type or length mismatch on column detailed-info
Explanation

During an attempt to synchronize the RDBMS table with the Adabas file, the Event Replicator Target Adapter determined that a data type or length mismatch had occurred for the column described by the detailed information listed in the message (detailed-info).

Action

Issue the same message as the previous one. The Event Replicator Target Adapter will continue to run because the Adabas-RDBMS Synchronization Level value is set to "warn". If the problem persists, contact your Software AG technical support representative for assistance.


ART1238I Alter column detailed-info
Explanation

The column described by the detailed information listed in the message (detailed-info) was altered in the RDBMS during Event Replicator Target Adapter synchronization between the RDBMS table and the Adabas file.

Action

No action is required for this informational message.


ART1239I Add column detailed-info
Explanation

The column described by the detailed information listed in the message (detailed-info) was added to the RDBMS during Event Replicator Target Adapter synchronization between the RDBMS table and the Adabas file.

Action

No action is required for this informational message.


ART1240E Cannot add column detailed-info
Explanation

The Event Replicator Target Adapter could not add the column described by the detailed information listed in the message (detailed-info) to the RDBMS during it's attempt to synchronize the RDBMS table with the Adabas file.

Action

Make sure the target database supports adding columns. If the problem persists, contact your Software AG technical support representative for assistance.


ART1241W Target database does not have column detailed-info
Explanation

During an attempt to synchronize the RDBMS table with the Adabas file, the Event Replicator Target Adapter determined that the target RDBMS is missing the column described by the detailed information listed in the message (detailed-info).

This message is issued because the Adabas-RDBMS Synchronization Level value is set to "warn". In this case, the Event Replicator Target Adapter issues this warning message and continues processing.

Action

No action is required for this warning message.


ART1242E Cannot find _INDEX as suffix of the PE table tablename primary key key
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1243W Response code nn received for operation: operation
Explanation

The Event Replicator Target Adapter received an unexpected response code nn for the described operation.

Action

Please check the Replicator SYSOUT for further details.


ART1244I Transaction {number} ignored as it has been previously processed.
Explanation

Transaction caching is active and the Event Replicator Target Adapter has attempted to process a transaction which has already been recorded as processes.

Action

Verify the integrity of the replicated data.


ART1245I Transaction cache disabled.
Explanation

Informational message at startup notifying transaction caching is disabled. This is the default behavior.

Action

No action is required for this informational message.


ART1246I Dynamically adjust flags (DeleteBeforeInsert, ContinueOnSQLError) during Initial State time stamp boundaries: ON
Explanation

Informational message displayed at startup, indicating enhanced ADARIS Initial State processing is active.

Action

No action is required for this informational message.


ART1302I Loader complete for loader
Explanation

The Event Replicator Target Adapter completed loading replicated data for the Oracle SQL Loader listed in the message without failing.

Action

No action is required for this informational message.


ART1303E Loader fail. Please check the log files fn
Explanation

An attempt to load replicated data to the database via the Oracle SQL loader failed. The log files (fn) that contain more information are listed in the message.

Action

Review the log files for more information about the failure. If possible, correct the error and try again. If the problem persists, contact your Software AG technical support representative for assistance.


ART1304E Loader exception
Explanation

An exception occurred during the loading process.

Action

Contact your Software AG technical support representative for assistance.


ART1305E Create table XML file fn does not exist
Explanation

A request to create the table in an XML file failed because the XML file could not be found. The filename of the XML file is given in the message (fn).

Action

Contact your Software AG technical support representative for assistance.


ART1307E Control file fn is not generated
Explanation

The control file listed in the message (fn) was not generated.

Action

Contact your Software AG technical support representative for assistance.


ART1308E Loader cannot support streaming mode
Explanation

The loader cannot support streaming mode.

Action

Modify the target database options used by the database so that the Use Stream option is not selected (checked) and try again. For more information, read Specifying Target Database Processing Option Definitions.


ART1309E Output file fn is not generated
Explanation

The output file named in the message (fn) was not generated.

Action

Contact your Software AG technical support representative for assistance.


ART1310I Current configuration cannot support streaming mode; change to nonstreaming mode
Explanation

The current configuration does not support streaming mode. The Event Replicator Target Adapter turns stream mode off and retries the operation.

Action

No action is required for this informational message.


ART1311I Current configuration cannot support loader mode; change to nonloader mode
Explanation

The current configuration does not support the database in loader mode.

Action

No action is required for this informational message.


ART1312I Loader process running for loader
Explanation

The database loader process is running for the Oracle SQL Loader listed in the message.

Action

No action is required for this informational message.


ART1313I Loader about to execute following command: cmd
Explanation

The database loader process is executing the command listed in the message (cmd).

Action

No action is required for this informational message.


ART1315I Create loader thread
Explanation

An attempt by the Event Replicator Target Adapter to create a loader thread is in process.

Action

No action is required for this informational message.


ART1316E Called with table: tblname column: colname
Explanation

An error occurred trying to call the table (tblname) and column (colname) whose names are listed in the message.

Action

Contact your Software AG technical support representative for assistance.


ART1318I Initial-state running in loader mode
Explanation

The initial-state process is running in loader mode.

Action

No action is required for this informational message.


ART1319E Cannot wait for loader process
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1320E Cannot find control file name
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1321E Cannot find log file name
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1322E Cannot find bad file name
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1323E Cannot find discard file name
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1324E Cannot find out file name
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1325E Create loader process failed
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1326I Test loader process successful
Explanation

The test loader process completed successfully.

Action

No action is required for this informational message.


ART1327E Test loader process failed, exit code code
Explanation

The test loader process failed with the exit code listed in the message (code).

Action

Contact your Software AG technical support representative for assistance.


ART1328E Cannot create XsltWorker
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1329E Cannot set up environment variables of file fn
Explanation

An attempt to set the environment variables for the file named in the message (fn) failed.

Action

Contact your Software AG technical support representative for assistance.


ART1330E Cannot support current database type
Explanation

Support is not provided for the database type.

Action

Change the database type to one that is supported by the Event Replicator Target Adapter. If necessary, contact your Software AG technical support representative for assistance.


ART1331E Worker is null
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1332E Cannot create loader thread
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1333E Cannot create piped stream
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1334E Loader failed. Current mode is streaming mode, change to nonstreaming mode and retry
Explanation

The loader failed.

Action

Modify the target database options used by the database so that the Use Stream option is not selected (checked) and try again. For more information, read Specifying Target Database Processing Option Definitions.


ART1335E Cannot write to output stream
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1336E Parsing error err line lll column ccc PID pid CID cid
Explanation

A parsing error occurred. The error, line number, column number, process ID, and command ID are given in the message.

Action

Contact your Software AG technical support representative for assistance.


ART1337E Unable to send message to the loader
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1338E Cannot find base file name
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1339W Current database cannot support streaming mode, reset to nonstreaming mode
Explanation

The current database does not support streaming mode. The Event Replicator Target Adapter has turned streaming mode off.

Action

No action is required for this warning message.


ART1340E The child thread may end unexpectedly
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1341E Cannot find WebDAV
Explanation

The WebDAV file cannot be found.

Action

Contact your Software AG technical support representative for assistance.


ART1342E Batch file fn does not exist
Explanation

The batch file named in the message does not exist.

Action

Contact your Software AG technical support representative for assistance.


ART1343W The service name of the loader in the Target Database Options of a Teradata MLoad, name, has more than num characters. Using xxxx as the tdpid for this MLoad
Explanation

The service name of the loader during Teradata MLoad processing is too long. The Event Replicator Target Adapter is using the name xxxx for the tdpid of the MLoad processing.

Action

No action is required for this warning message.


ART1344W The service name of the loader in the Target Database Options of a Teradata MLoad has not been informed. Attempting to use xxxx as the tdpid for ths MLoad
Explanation

The service name of the loader during Teradata MLoad processing has not been provided. The Event Replicator Target Adapter is trying to use the name xxxx for the tdpid of the MLoad processing.

Action

No action is required for this warning message.


ART1401I Transform document using XSLT file: fn token: token
Explanation

The Event Replicator Target Adapter is attempting to transform the document using the XSLT file (fn) and token (token) listed in the message.

Action

No action is required for this informational message.


ART1402E Cannot convert from UTF8 byte array to a string
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART1501I Source manager shutdown requested
Explanation

A request was made to shut down the source manager.

Action

No action is required for this informational message.


ART1502I Source manager notified to shut down
Explanation

The source manager has been notified to shut down.

Action

No action is required for this informational message.


ART1503I Waiting for source manager shutdown to complete
Explanation

The Event Replicator Target Adapter is waiting for the source manager to fully shut down.

Action

No action is required for this informational message.


ART1504I Source manager is down
Explanation

The source manager shutdown has completed.

Action

No action is required for this informational message.


ART1601I Engine manager shutdown requested
Explanation

A request was made to shut down the engine manager.

Action

No action is required for this informational message.


ART1602I Engine manager notified to shut down
Explanation

The engine manager has been notified to shut down.

Action

No action is required for this informational message.


ART1603I Waiting for engine manager shutdown to complete
Explanation

The Event Replicator Target Adapter is waiting for the engine manager to fully shut down.

Action

No action is required for this informational message.


ART1604I Engine manager is down
Explanation

The engine manager shutdown has completed.

Action

No action is required for this informational message.


ART1701W Parameter parm value val not numeric
Explanation

The parameter named in the message (parm) specifies a value (val) that is not numeric.

Action

Supply a numeric value for the parameter and try again.


ART1702W Parameter parm value val does not end with "S"
Explanation

The parameter named in the message (parm) specifies a value (val) that does not end in an "S".

Action

Supply a value for the parameter that ends in an "S" and try again.


ART1703W Parameter parm value val is not "true" or "false"
Explanation

The parameter named in the message (parm) specifies a value (val) that is not "true" or "false."

Action

Supply a "true" or "false" value for the parameter and try again.


ART1801E Cannot open WebSphere MQ trace log file fn
Explanation

An attempt to open the WebSphere MQ trace file named in the message (fn) failed.

Action

Check your definition. Verify that the directory defined in your definitions exists.


ART1802E WebSphere MQ rollback failed err-code
Explanation

A rollback attempt for WebSphere MQ failed.

Action

Review the webSphere MQ documentation to determine the reason for the failure.


ART1803E WebSphere MQ logon failed host hostid port portnum error err
Explanation

An attempt to logon to WebSphere MQ failed. The WebSphere MQ host ID (hostid), port number (portnum), and the error number (err) from the attempt are given in the message.

Action

Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again.


ART1804I WebSphere MQ logon to host hostid successful
Explanation

The attempt to log onto the WebSphere MQ host named in the message (hostid) was successful.

Action

No action is required for this informational message.


ART1805I WebSphere MQ receiving messages from queue qname
Explanation

WebSphere MQ is receiving and processing messages from the queue listed in the message (qname).

Action

No action is required for this informational message.


ART1806E WebSphere MQ request failed
Explanation

A WebSphere MQ request failed.

Action

Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again.


ART1807E WebSphere MQ receive failed err-code
Explanation

A receive request via the WebSphere MQ queue failed.

Action

Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again.


ART1808E WebSphere MQ commit failed err-code
Explanation

A commit request via the WebSphere MQ queue failed.

Action

Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again.


ART1809E WebSphere MQ send failed err-code
Explanation

A send request via the WebSphere MQ queue failed.

Action

Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again.


ART1810E WebSphere MQ close failed err-code
Explanation

A close request via the WebSphere MQ queue failed.

Action

Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again.


ART2001E Required target configuration not found config or default
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART2002E Operation is null
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART2003E Operation opname is not supported
Explanation

An attempt to run the operation named in the message (opname) failed because it is not supported.

Action

Try an operation that is supported.


ART2004E Not SOAP element
Explanation

An internal error occurred.

Action

Contact your Software AG technical support representative for assistance.


ART3001E Wrong factory type for msgtype. Type is factype.
Explanation

An attempt to use the wrong JMS factory type for the type of messaging specified. The message type (msgtype) and factory type (factype) are given in the message. Replicate the data to a JMS topic if you want to use publish-subscribe messaging; replicate the data to a JMS queue if you want to use point-to-point messaging.

Action

Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance.


ART3002E Factory factory not found in the naming system.
Explanation

An attempt to access the JMS topic or queue connection factory in the system was not successful.

Action

Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance.


ART3003E Error occurred while accessing factory factory in the naming system system.
Explanation

An error occurred attempting to access the JMS topic or queue connection factory named in the message in the system named in the message.

Action

Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance.


ART3004E Wrong destination type for jmsname. Type is factype.
Explanation

An attempt to use the wrong type of destination was made when replicating data to JMS queues or topics. The JMS destination topic or queue name (jmsname) and the factory type (factype) are given in the message. Specify the destination as a JMS topic (as defined to webMethods Broker) if you want to use publish-subscribe messaging; specify the destination as a JMS queue (as defined to webMethods Broker) if you want to use point-to-point messaging.

Action

Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance.


ART3005E Destination dest not found in the JNDI provider
Explanation

An internal error occurred. The destination specified in the JMS target definition was not found in the JNDI provider specified in the JMS target definition. The destination name is given in the message.

Action

Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance.


ART3006E Error while accessing destination dest
Explanation

An internal error occurred. An error occurred during an attempt to access the destination specified in the JMS target definition.

Action

Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance.