Additional user abend codes can be found in the Beta product Messages and Codes manuals.
User abend code |
Module causing the abend |
---|---|
U0222 |
BST09DPL |
U0905 |
BST08ARC |
U0939 |
BST01PC |
U0920 |
BST01LK |
U0930 |
BST01SS |
U0950 |
BST01DS |
U0960 |
BST01DMP |
U0971 |
BST01FC |
U0988 |
BST01FR |
U0990 |
BST01GI |
U0991 |
BST01GI |
U0992 |
BST01AL |
U0992 |
BST01FT |
U0993 |
BST01FA |
U0993 |
BST01OAL |
U0994 |
BST01GT |
U0997 |
BST01SIP |
U0999 |
BST05MCT |
U4000 |
BST12IVP |
U4001 |
BST12I00 |
The system ends with one of the above abend codes.
Please save the dump and contact support.
An invalid storage GETMAIN or FREEMAIN request was attempted. This could happen if no more private area allocated to the Subsystem Function Facility is readily available to complete a GETMAIN request.
BST01SC.
The entire subsystem terminates with this abend code.
Increase the region size parameter in the started task procedure in the step executing BST01SFF. Or monitor the workload in your Beta product started task and reduce the number of concurrent work requests that can be active at any one time. Otherwise please contact support.
A non-zero return code was received from the OS LOAD macro. This is done when a program is loaded into virtual storage for LINK or XCTL.
BST01PC.
The subsystem abends with the above abend code.
Check to make sure that the program specified is inside of one of the STEPLIB libraries and that the requested load module is not marked as being non-executable. Contact your system programming support to get this error resolved.
A return code was received from the OS ATTACH macro when starting a new function group.
BST01GA.
The subsystem terminates with the above abend code.
Check that the installation of the subsystem is correct, and check the subsystem region size; it could be too small. A minimum size of about 5 MB is required. Contact your system programming support to get this error resolved.
The OS ENQUEUE failed at start-up time. This ENQUEUE is done to ensure that only one subsystem is running with the same z/OS subsystem name.
BST01SIP.
The subsystem terminates with the above abend code.
Check whether there is already a subsystem running under the same z/OS subsystem name. Contact your system programming support to get this error resolved.
The IMS transaction of _beta iaf is unable to pass a request to DL1 to
BST12I00.
The transaction terminates with the above abend code.
See IMS Messages and Codes to determine the cause of the error.