Inserting modifiable keywords and values

Inserting modifiable keywords and values

Overview

Use line command I in the "Display Modifiable Parameter Keywords/Values" table to insert new keywords and values to the ones currently active in a started task.

Note the following:

  • You can only insert modifiable keywords that have not yet been activated. These are the keywords that have N in column A.
  • Any changes made in this way will only be temporary. When the product started task is stopped and restarted, the changes will no longer be effective. If you want to make a permanent change, modify the keyword in the LST member of the product STC.

Procedure

  1. In the "Display Parameter Keywords/Values" table, enter I in front of the keyword that you want to insert. The "Insert Parameter Keyword Value" panel is opened:

    PEB4KW2I ----------------------------------------------------------------------
    Command ===> _________________________________________________________________

    Insert Parameter Keyword Value Subsys-ID - S93P
    Sysname - BETA


    Keyword : BQL_TRACE

    Value ===> .............................................................
    ................................................................................
    ................................................................................
    .................................








    Press the ENTER key to process your input.
    Press the END key to return to the previous panel.

  2. Specify a value for the keyword, for example YES.

    Lists of valid values for the various keywords can be found in the BSA Installation and System Guide and in the product documentation.

Result

The "Result" panel confirms that the keyword was successfully inserted and reminds you that the insert is only temporary.