Deleting keywords and values

Deleting keywords and values

Overview

Use line command D in the "Display Parameter Keywords/Values" table to delete a keywords and its value. Please note the following:

  • You can only use line command D to delete keywords for which modification is allowed. This is indicated by a Y in column U of the "Display Parameter Keywords/Values" table.
  • Keywords deleted in this way will only be removed temporarily. When the product started task is stopped and restarted, the changes will no longer be effective. To make a permanent change, you will need to deactivate the keyword in the actual LST member of the product STC.
  • When you delete a keyword, its default will be used in the LST member. Please refer to the product documentation.

Procedure

  1. In the "Display Parameter Keywords/Values" table, enter line command D in front of the keyword that you want to delete.
  2. Confirm that you want to delete this keyword.

Result

The deletion is confirmed and you are reminded that the change is only temporary:

PEB4DISD ----------------------------------------------------------------------
 Command ===> _________________________________________________________________

 Delete Parameter Keyword - Result Subsys-ID - S93P
 Sysname - BETA


 The keyword B93_DISPLAY_LIMIT_BYPASS
 was successfully deleted.



 Caution:
 This change is only temporary. After restarting the product STC with the
 Subsystem-ID S93P , the delete of the Keyword will no longer be active.
 To activate this delete permanently, please delete the keyword
 B93_DISPLAY_LIMIT accordingly in the LST member of the product STC.





 Press the END key to return to the previous panel.