Verification

Instructions

To verify installation/maintenance:

  1. Start the Adabas Audit Data Retrieval started task and check the JESMSGLG (displayed levels, database status, TCP/IP status) in SDSF.

    IRM9151I B97LSTxx LOADED, SVC(svcnum/PBS4215/epaddr) SSID(ssid)
    SYSNAME(sysname) SYSPLEX(sysplex) SYSTEM(z/OSn.nn) ASIDX(asidx)
    IRM9151I BSA INITIALIZATION 177100 LEVEL: 02 / PBS4297 / PBS4244
    IRM9151I CPU INFORMATION - TYPE: tttt ID: nnnn LPAR: l TLCPU: tccc CLCPU: cccc SLCPU: sccc
    IRM9005I LICENSE FILE filename WILL BE USED
    IRM9004I product HAS BEEN LICENSED FOR CUSTOMER: customername
    IRM9006I LICENSED CPU-TYPES: cputype
    IRM9557I DATABASE INITIALIZATION WITH VERSION: PBS4398 / PBS4397
    ...
    IRM9154I BSA HAS STARTED BETA97 G7 SYSTEM LEVEL V7R2-00 PIR0436

    where:

    xx
    svcnum
    epaddr
    ssid
    sysname
    sysplex
    asidx
    tttt
    nnnn
    l
    tccc
    cccc
    sccc
    filename
    customername

    cputype

    Identifier of the LST member
    Your SVC number
    Entry point address of the SVC
    Your subsystem ID
    Name of your z/OS system
    Name of your sysplex
    Address space ID assigned to STC/JOB
    Machine type
    Machine ID
    LPAR number
    Total LCPU count
    Configured LCPU count
    Standby LCPU count
    Name of the license file to be used
    Name of customer to whom this license was issued
    (as specified in the license file)
    List of the CPU types for which the license is valid

  2. Call the Adabas Audit Data Retrieval ISPF application and verify the upgrade status of the database (option S.2, line command V).

    The message Verification successful indicates that all required database updates have been successfully installed.

    If one of the table entries displays NO in the column INSTALLED, check the step on database update, and verify the return codes of the insert statements.

    You can also run the database verification job B97DBVER (for more information on verification, refer to the corresponding section in the Adabas Audit Data Retrieval Installation and System Guide).

    Do NOT use the database if the INSTALLED column shows a NO.

If STC start leads to IRM9169E or IRM9197E

A level check is carried out when a Beta product is started. If the Beta SVC level does not correspond to the Beta control program, the Beta product will not be started and the message IRM9169E or IRM9197E is issued.

The most likely cause is one or both of the following:

  • The SVC has not been updated.
  • BST01ARI (B97INIT) has not run to initialize the subsystem.