Product installation and maintenance jobs

Which B97 jobs need to run?

The job table in the current section shows which product installation jobs have to be run by new and existing users of Adabas Audit Data Retrieval.

Before submitting product installation jobs...

Before submitting any product installation jobs, stop all Adabas Audit Data Retrieval V7 started tasks using target libraries referenced in the DDDEFs in your SMP/E environment.

Job table

The following table shows the jobs that have to run in sequence (top‑down) when installing or applying maintenance to Adabas Audit Data Retrieval. For more information on each job, see Adabas Audit Data Retrieval Installation and System Guide.

Run the jobs that are marked with an X in the column of your currently installed level. (X) indicates that a job has to run under certain conditions only. A superscripted number indicates the presence of a note with additional information. Read this note first before submitting the job.

 

 

 

 

New installation

 

 

 

Max. RC (stepname if rc<>0)

 

 

 

 

Your RC

 

 

 

 

 

Your notes

I#B97J01: allocate libraries

 

X

0

 

 

I#B97J02: add product DDDEFs

 

X

0

 

 

I#B97J03: receive functions/PTFs

 

(X)1

0

 

 

I#B97J04: apply/accept functions

 

X

0

 

 

I#B97J05: apply PTFs

 

X

0 or 122
(IRMPTFS)

 

 

I#B97J06: copy B97LSTxx/B97SSIxx

 

X

0

 

 

I#B97J07: copy STC procedures and reload procedure B97RLDA

 

X

0

 

 

B97UMPRE: usermod PE97STRT

 

X3

0

 

 

Copy B97CLIST to DD SYSPROC

 

X4

n/a

 

 

B97LGFJ1: allocate LGFSLIB

 

X

0

 

 

B16LGFJ2 (BSA job): copy BSA members

 

X

0

 

 

Note 1: I#B97J03

I#B23J02 and I#B97J03 each receive all Beta 23 and all Adabas Audit Data Retrieval functions and PTFs from the installation dataset. If I#B23J02 has already run in the same environment, I#B97J03 will not find anything to receive and will end with RC=4. (BSA functions and BSA PTFs are received by I#BSAJ08.)

Note 2: I#B97J05

RC=12 is okay if it is caused by the following error (no PTFs available):

GIM24801S ** NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY COMMAND.

Always check the log to make sure that no other errors have occurred.

We recommend that you contact support to find out whether there are any newer PTFs that should be installed.

Note 3: B97UMPRE

B97UMPRE receives and applies the non-displayable start panel PE97STRT as a usermod. This panel is called for first-time users of Adabas Audit Data Retrieval to set appropriate defaults for subsystem ID, system name, location etc. in the user's variable pool.

B97UMPRE ends with RC=12 if the corresponding usermod is already present. If you want to replace it, reject this usermod and then rerun B97UMPRE.

Note 4: Copy B97CLIST to DD SYSPROC

Copy the CLIST to one of the procedure libraries defined under DD SYSPROC in your TSO logon procedures.

Note: When calling the CLIST via a panel, do not use the parameter NEWAPPL(BSS) or NEWAPPL(BST). Calling the CLIST with these parameters will lead to unpredictable results.