Adabas Audit Data Retrieval installation batch jobs (I#B97J01-I#B97J07)

Adabas Audit Data Retrieval installation batch jobs (I#B97J01-I#B97J07)

Job summary

Job

Description

max. RC

I#B97J01

Allocates the Adabas Audit Data Retrieval distribution and target libraries on disk

0

I#B97J02

Makes DD definitions in the target and distribution zones for the datasets needed by SMP/E for installation

0

I#B97J03

Receives functions and accumulated PTFs (if present)

0 or 4

I#B97J04

Applies and accepts the Adabas Audit Data Retrieval function

4

I#B97J05

Applies all accumulated Adabas Audit Data Retrieval PTFs

The job ends with RC=12 if there are no PTFs.

4
(12)

I#B97J06

Copies the members B97LSTxx and B97SSIxx to the BETA.PARMLIB

0

I#B97J07

Copies the started task procedure(s) into the specified system procedure library

0

B97UMPRE

Receives and applies the tailored non-displayable start panel PE97STRT as USERMOD

0

I#B97J01

This job allocates the Adabas Audit Data Retrieval distribution and target libraries. Space values refer to type 3390 DASD units. Expect RC=0.

DD name

Dataset name

Space

Purpose

IRMLOAD

hlq.LOAD

40 cyl

Target load module library

AIRMLOAD

hlq.ALOAD

40 cyl

Distribution load module library

IRMPLIB

hlq.ISPPLIB

20 cyl

Target ISPF panel library

AIRMPLIB

hlq.AISPPLIB

20 cyl

Distribution ISPF panel library

IRMMLIB

hlq.ISPMLIB

 2 cyl

Target ISPF message library

AIRMMLIB

hlq.AISPMLIB

 2 cyl

Distribution ISPF message library

IRMSLIB

hlq.ISPSLIB

 1 cyl

Target skeleton library

AIRMSLIB

hlq.AISPSLIB

 1 cyl

Distribution skeleton library

IRMSAMP

hlq.SAMPLIB

 2 cyl

Target Sample library

AIRMSAMP

hlq.ASAMPLIB

 2 cyl

Distribution Sample library

I#B97J02

This job makes DD definitions in the target and distribution zones for the datasets needed by SMP/E for installation. Expect RC=0.

I#B97J03

This job receives the Adabas Audit Data Retrieval function and all accumulated PTFs. Expect RC=0.

SYSMOD entries:

 

Function

PTFs

APARs

Description

IRM

SIR7200

PIR....

TIR....

Adabas Audit Data Retrieval

I#B97J04

This job applies and accepts the Adabas Audit Data Retrieval function. Expect RC=0.

I#B97J05

This job applies all Adabas Audit Data Retrieval accumulated PTFs.

Standard SMP/E return codes for this job are:

0

PTFs applied.

4

PTFs applied. This return code is typically okay (see below).

8

Error. First check whether there are any PTFs with the SMP/E parameter ++HOLD... SYSTEM REASON(...). You can find this information with additional instructions in the accompanying Release Notes and Update Instructions or Technical Note. Otherwise, please contact support.

12

No PTFs for FMID. Check the accompanying release notes to find out whether there are any PTFs. RC=12 is okay if there are no PTFs.

RC=4 is okay if caused by the following warning messages:

GIM23903W LINK-EDIT PROCESSING FOR SYSMOD ptfnnnn WAS SUCCESSFUL
FOR MODULE modname IN LMOD modname IN THE IRMLOAD
LIBRARY. THE RETURN CODE WAS 04. date time seq#.
GIM23904W LINK-EDIT PROCESSING FOR LOAD MODULE BUILD PROCESSING
WAS SUCCESSFUL FOR MODULE modname IN LMOD modname IN
THE IRMLOAD LIBRARY. THE RETURN CODE WAS 04. date time
seq#.

Note on copying load libraries

We recommend using IEBCOPY with COPYMOD for copying load libraries.

Copying load libraries with ISPF may lead to problems under certain conditions.

I#B97J06

This job copies the parmlib members B97LSTxx and B97SSIxx to the BETA.PARMLIB. Expect RC=0.

The parmlib member B97LSTxx contains parameters for the product started task and batch utilities. The member is tailored according to your specifications by the installation REXX. xx can be any two-digit numeric or alphabetic character combination. For more information, see "How to use LST parameters".

The parmlib member B97SSIxx is used as input during subsystem initialization. For more information, see the description of member B97SSIxx in "Step 3: Defining subsystem and initializing subsystem environment".

I#B97J07

This job copies the started task procedure into the system procedure library that you specified when running the installation REXX. If a procedure of the same name already exists in the corresponding procedure library, this job will replace the existing one. Expect RC=0.

I#B97J07 also copies the procedure for automatic reload to the designated system procedure library.

The default name of the Adabas Audit Data Retrieval started task procedure is BETA97.

You may have specified a different name when running the installation REXX.

Note: The name of the product started task procedure must be different from the name of the product subsystem ID. If the names are identical, you will get a JCL error when trying to start the started task.