Job |
Description |
max. RC |
---|---|---|
Allocates the Adabas Audit Data Retrieval distribution and target libraries on disk |
0 |
|
Makes DD definitions in the target and distribution zones for the datasets needed by SMP/E for installation |
0 |
|
Receives functions and accumulated PTFs (if present) |
0 or 4 |
|
Applies and accepts the Adabas Audit Data Retrieval function |
4 |
|
Applies all accumulated Adabas Audit Data Retrieval PTFs The job ends with RC=12 if there are no PTFs. |
4 |
|
Copies the members B97LSTxx and B97SSIxx to the BETA.PARMLIB |
0 |
|
Copies the started task procedure(s) into the specified system procedure library |
0 |
|
Receives and applies the tailored non-displayable start panel PE97STRT as USERMOD |
0 |
This job allocates the Adabas Audit Data Retrieval distribution and target libraries. Space values refer to type 3390 DASD units. Expect RC=0.
DD name |
Dataset name |
Space |
Purpose |
IRMLOAD |
hlq.LOAD |
40 cyl |
Target load module library |
AIRMLOAD |
hlq.ALOAD |
40 cyl |
Distribution load module library |
IRMPLIB |
hlq.ISPPLIB |
20 cyl |
Target ISPF panel library |
AIRMPLIB |
hlq.AISPPLIB |
20 cyl |
Distribution ISPF panel library |
IRMMLIB |
hlq.ISPMLIB |
2 cyl |
Target ISPF message library |
AIRMMLIB |
hlq.AISPMLIB |
2 cyl |
Distribution ISPF message library |
IRMSLIB |
hlq.ISPSLIB |
1 cyl |
Target skeleton library |
AIRMSLIB |
hlq.AISPSLIB |
1 cyl |
Distribution skeleton library |
IRMSAMP |
hlq.SAMPLIB |
2 cyl |
Target Sample library |
AIRMSAMP |
hlq.ASAMPLIB |
2 cyl |
Distribution Sample library |
This job makes DD definitions in the target and distribution zones for the datasets needed by SMP/E for installation. Expect RC=0.
This job receives the Adabas Audit Data Retrieval function and all accumulated PTFs. Expect RC=0.
SYSMOD entries:
|
Function |
PTFs |
APARs |
Description |
IRM |
SIR7200 |
PIR.... |
TIR.... |
Adabas Audit Data Retrieval |
This job applies and accepts the Adabas Audit Data Retrieval function. Expect RC=0.
This job applies all Adabas Audit Data Retrieval accumulated PTFs.
Standard SMP/E return codes for this job are:
0 |
PTFs applied. |
4 |
PTFs applied. This return code is typically okay (see below). |
8 |
Error. First check whether there are any PTFs with the SMP/E parameter ++HOLD... SYSTEM REASON(...). You can find this information with additional instructions in the accompanying Release Notes and Update Instructions or Technical Note. Otherwise, please contact support. |
12 |
No PTFs for FMID. Check the accompanying release notes to find out whether there are any PTFs. RC=12 is okay if there are no PTFs. |
RC=4 is okay if caused by the following warning messages:
GIM23903W LINK-EDIT PROCESSING FOR SYSMOD ptfnnnn WAS SUCCESSFUL |
We recommend using IEBCOPY with COPYMOD for copying load libraries.
Copying load libraries with ISPF may lead to problems under certain conditions.
This job copies the parmlib members B97LSTxx and B97SSIxx to the BETA.PARMLIB. Expect RC=0.
The parmlib member B97LSTxx contains parameters for the product started task and batch utilities. The member is tailored according to your specifications by the installation REXX. xx can be any two-digit numeric or alphabetic character combination. For more information, see "How to use LST parameters".
The parmlib member B97SSIxx is used as input during subsystem initialization. For more information, see the description of member B97SSIxx in "Step 3: Defining subsystem and initializing subsystem environment".
This job copies the started task procedure into the system procedure library that you specified when running the installation REXX. If a procedure of the same name already exists in the corresponding procedure library, this job will replace the existing one. Expect RC=0.
I#B97J07 also copies the procedure for automatic reload to the designated system procedure library.
The default name of the Adabas Audit Data Retrieval started task procedure is BETA97.
You may have specified a different name when running the installation REXX.
Note: The name of the product started task procedure must be different from the name of the product subsystem ID. If the names are identical, you will get a JCL error when trying to start the started task.