9502E
SYSLOG, JESMSGLG.
The product has been started and an attempt was made to activate the BQL speedmaster function with the buffer value defined for DATA and/or KEY files in the database definition file. The BQL speedmaster function could not be activated because of lack of storage.
The Beta product started task or batch job cannot be started.
Run BnnCLSYN to clear the SYNC file, increase the REGION value in the JCL of the started task or batch job, and try to restart the product.
If the error persists, you have to reduce the buffer value defined for the DATA and/or KEY files in the database definition file. Proceed as follows:
Start the program with the LST parameter BQL_SPEEDMASTER = NO. For more information on the parameters of BST05UPF, see "Updating file information in the database definition file (BST05UPF)" in BSA Installation and System Guide.
Make sure that you start the product with the LST parameter BQL_SPEEDMASTER = YES. Otherwise serious performance problems could occur.