9330E

9330E

9330E INVALID PORT NUMBER port FOR CONNECTION TO THE BSA CI HAS BEEN FOUND

Written to:

SYSLOG, JESMSGLG.

Explanation:

A command to display/control BSA Communication Integrator was sent from the product started task via the BSA Service Manager. To enable this, a valid TCP/IP connection to BSA Communication Integrator must be defined in keyword BSA_TCPIP_BSM_PORT in the LST member of the product started task. Either this definition could not be found, or the port specified in the keyword is incorrect.

System Action:

The command is not executed.

Operator Response:

Eliminate the cause of the error. If the BSM port is defined and active in the BSA Communication Integrator (message 8518I), this port must also be defined in keyword BSA_TCPIP_BSM_PORT in the LST member of the product started task. This definition can also be made temporarily using the BSA Service Manager (option 1). Also refer to the chapter on the BSA Communication Integrator in the BSA Installation and System Guide.