9262E

9262E

9262E SERVER(port/app): BIND FAILED: text

Written to:

SYSLOG, JESMSGLG.

Explanation:

The BSA TCP/IP server has tried to bind to the address/port of a PORT LST parameter. The bind has failed. text describes which error occurred:

  • LOGICAL ERROR (resolveno/srchno)

    A logical error occurred while processing the resolved IP addresses.

  • FAMILY - family RC - rc ERRNO - error IPA – resipa

    A bind error occurred while processing the resolved IP address resipa.

where:

resolveno

Number of the entry in the internal resolution table

srchno

Total number of entries in the internal resolution table

port

Port number

app

shows the application name (add-on) of the port or BSA when the global port is used

family

Address family, which describes the IP protocol used for the IP address resipa

rc

Return code

error

TCP/IP error code

resipa

Resolved numeric IP address that was used

Notation and separator are determined by the family.

System Action:

The bind request is terminated. Communication with the specified port port and the IP address resipa is not possible.

Operator Response:

Determine the cause of this error, eliminate it and restart the TCP/IP server. If the error persists, contact support.