9251E
Operator console, PMSLOG.
An attempt was made to start a TCP/IP server with the port number port via the MODIFY command. Previously a TCP/IP server with the same port number has been activated. This active TCP/IP server has been stopped or ended abnormally via the MODIFY command. When the TCP/IP server has been stopped, not all of the server functions could be stopped as normal. The server could not be restarted successfully.
name |
Name of the group in the format type_hport where: type Application type hport Server port number in hexadecimal format Example: OSY_2710 (i.e. decimal port number 10000) |
The subsystem continues processing. The TCP/IP server cannot be started correctly.
Stop the TCP/IP server and restart it via the MODIFY command. See also the BSA Installation and System Guide for more information.