9251E

9251E

9251E TCP/IP ROUTER: SERVER CLIENT GROUP name HAS NOT BEEN STARTED

Written to:

Operator console, PMSLOG.

Explanation:

An attempt was made to start a TCP/IP server with the port number port via the MODIFY command. Previously a TCP/IP server with the same port number has been activated. This active TCP/IP server has been stopped or ended abnormally via the MODIFY command. When the TCP/IP server has been stopped, not all of the server functions could be stopped as normal. The server could not be restarted successfully.

name

Name of the group in the format type_hport where:

type

Application type

hport

Server port number in hexadecimal format

Example: OSY_2710 (i.e. decimal port number 10000)

System Action:

The subsystem continues processing. The TCP/IP server cannot be started correctly.

Operator Response:

Stop the TCP/IP server and restart it via the MODIFY command. See also the BSA Installation and System Guide for more information.