9196E

9196E

9196E SUBSYSTEM ID (ssid) HAS NOT BEEN DEFINED TO z/OS OR NOT INITIALIZED

Written to:

Operator console.

Explanation:

SFF cross-memory connection processing could not locate the SSCT control block associated with subsystem ssid.

System Action:

SFF initialization processing is terminated with RC=16.

Operator Response:

Depending on the cause of the error, which may be a simple typo in the value of the subsystem parameter, do the following:

  • Check which product subsystem ID is specified in the BnnLSTxx member of the BETA.PARMLIB. If necessary, correct it and restart the started task.
  • Check whether the correct subsystem ID has been specified in the member IEFSSNxx of the z/OS PARMLIB (changes take effect after an IPL, but you can also define the subsystem dynamically via the operator command SETSSI ADD,SUB=ssid).

For a description of the BnnLSTxx member, see chapter "Customization" in the product's Installation and System Guide.

For information on defining and initializing subsystems, see "Specifying a subsystem ID and initializing the subsystem" in BSA Installation and System Guide.