8185E RETURN TO PROGRAM name FAILED / REJECTED

Written to:

SYSLOG, JESMSGLG.

Explanation:

It was not possible to return to program name, which was specified to be called by CAF parameter RETPGM=name at session logoff.

  • Error status FAILED indicates error condition PGMIDERR. Program name could not be found or loaded.
  • Error status REJECTED indicates that the user is not authorized to access the program (NOTAUTH).

System Action:

The CAF session is terminated and control is returned to the next logical level or to CICS. This error does not affect the CICS interface itself. However, in the case of error condition FAILED, all users are affected at logoff.

Operator Response:

  • If the program call is REJECTED, check the security definitions (permissions) of the user or users concerned. If appropriate, choose a different program to return to .
  • If the program call is FAILED (PGMIDERR), check all the program-relevant definitions in CICS and CAFPARM:
    • Check and adjust the PPT definition for the return program. Make sure that the program is in a CICS STC load library (under DFHRPL) that is defined to CICS, and is enabled. For further information, please refer to the corresponding IBM manual.